FC 40 W/840
Equipment / Accessories
- Exclusively for operation on electronic control gears
References / Links
For more information on the system guarantee and the terms and conditions of the guarantee visit https://www.inventronics-light.com/multilevel-guarantees
For more information on QUICKTRONIC electronic control gear go to www.osram.com/QUICKTRONIC
Technical Data
Electrical data
Nominal current
0.32 A
Photometrical data
Light color (designation)
LUMILUX Cool White
Rated LLMF at 2,000 h
0.85
Rated LLMF at 4,000 h
0.83
Rated LLMF at 6,000 h
0.8
Rated LLMF at 8,000 h
0.8
Rated LLMF at 12,000 h
0.75
Luminous flux
3400 lm
Dimensions & weight
Tube diameter
16 mm
Maximum diameter
16 mm
Product weight
83.75 g
Overall length
315.00 mm
Temperatures & operating conditions
Rated ambient temp.w.max.luminous flux
35.0 °C
Lifespan
Service life
8000 h
Operation mode LLMF/LSF
HF
Additional product data
Mercury content
3.0 mg
Product remark
Suitable for ECG operation only
Appropriate disposal acc. to WEEE
Yes
Capabilities
Suitable for indoor
Yes
Certificates & standards
Energy efficiency class
G
Energy consumption
43.89 kWh/1000h
Environmental information
Information according Art. 33 of EU Regulation (EC) 1907/2006 (REACh)
Date of Declaration
19-01-2022
Primary Article Identifier
4050300528526
Declaration No. in SCIP database
In work
Packaging information
EAN |
Unit |
Piece |
Dimension l x w x h |
Weight |
Volume |
---|---|---|---|---|---|
4050300528526 |
FS
| 1 | 306mm x 302mm x 23mm | 179.00g | 2.13dm³ |
4050300528533 |
VS
| 12 | 375mm x 320mm x 328mm | 2787.00g | 39.36dm³ |
4052899404342 |
VS
| 12 | 319mm x 300mm x 324mm | 2646.00g | 31.01dm³ |
Downloads
Lamp-ECG Combination
QTi 1x14/24/21/39 GII
Nominal current
0.19 A
Nominal wattage + Power loss
43.00 W
Power factor λ [PIM]
0.96
Luminous flux at 35 °C
3200 lm
Number of lighting outlets
1
QTi 2x14/24/21/39 GII
Nominal current
0.36 A
Nominal wattage + Power loss
88.00 W
Power factor λ [PIM]
0.99
Luminous flux at 35 °C
3200 lm
Number of lighting outlets
2
QTi 2x21/39 DIM
Nominal current
0.36 A
Nominal wattage + Power loss
82.00 W
Power factor λ [PIM]
0.98
Luminous flux at 35 °C
3100 lm
Ambient temperature range [PIM] REM
Operation at up to -20 °C for all QTi (DALI) DIM-ECG possible. Lowest dimming position must be limited. Details see technical dimming brochure.
Number of lighting outlets
2
QT-M 2x26-42/220-240 S
Nominal current
0.36 A
Nominal wattage + Power loss
88.00 W
Power factor λ [PIM]
0.97
Luminous flux at 35 °C
3200 lm
Number of lighting outlets
2
QTP-M 1x26-42
Nominal current
0.19 A
Nominal wattage + Power loss
43.00 W
Power factor λ [PIM]
0.97
Luminous flux at 35 °C
3200 lm
Number of lighting outlets
1
Information about Family
Ecodesign regulation information:
Separate control gear and light sources must be disposed of at certified disposal companies in accordance with Directive 2012/19/EU (WEEE) in the EU and with Waste Electrical and Electronic Equipment (WEEE) Regulations 2013 in the UK. For this purpose, collection points for recycling centres and take-back systems (CRSO) are available from retailers or private disposal companies, which accept separate control gear and light sources free of charge. In this way, raw materials are conserved and materials are recycled.
Separate control gear and light sources must be disposed of at certified disposal companies in accordance with Directive 2012/19/EU (WEEE) in the EU and with Waste Electrical and Electronic Equipment (WEEE) Regulations 2013 in the UK. For this purpose, collection points for recycling centres and take-back systems (CRSO) are available from retailers or private disposal companies, which accept separate control gear and light sources free of charge. In this way, raw materials are conserved and materials are recycled.
Products
Product |
|
Data sheet | ||
---|---|---|---|---|
![]() |
FC 22 W/830
|
240.00 mm | ||
![]() |
FC 22 W/840
|
240.00 mm | ||
![]() |
FC 40 W/830
|
315.00 mm | ||
![]() |
FC 40 W/840
|
315.00 mm |