HE 14 W/840

• Good economy and efficiency • Up to 20 % more economical than LUMILUX T8 • Up to 50 % smaller volume than comparable T8 lamps
• Public buildings • Offices • Shops • Supermarkets and department stores • Industry • Outdoor applications only in suitable luminaires

References / Links
For more information on the system guarantee and the terms and conditions of the guarantee visit www.osram.com/system-guarantee

Technical Data

Additional product data

Appropriate disposal acc. to WEEE

Yes

Predecessor EAN

4050300464688

Successor EAN

4050300591384

Certificates & standards

Energy efficiency class

F

Environmental information


Information according Art. 33 of EU Regulation (EC) 1907/2006 (REACh)

Date of Declaration

18-04-2022

Primary Article Identifier

4050300464688 | 4050300591384

Declaration No. in SCIP database

In work

Packaging information

EAN

Unit

Piece

Dimension l x w x h

Weight

Volume

4050300464688 UNV

Unpacked

1
4050300591384 FLH

Sleeve

1 570mm x 23mm x 23mm 63.00g 0.30dm³
4050300464695 VS

Shipping box

40 598mm x 95mm x 198mm 2580.00g 11.25dm³
4050300591391 VS

Shipping box

20 587mm x 90mm x 129mm 1503.00g 6.82dm³

Downloads

Lamp-ECG Combination
QT-ECO 1x4-16/220-240 S

Nominal current

0.10 A

Nominal wattage + Power loss

15.00 W

Power factor λ [PIM]

0.60 c

Luminous flux at 35 °C

1150 lm

Number of lighting outlets

1

EEI – Energy Label

A2

QT-FIT 5 1x14-35

Nominal current

0.08 A

Nominal wattage + Power loss

16.00 W

Power factor λ [PIM]

0.95

Luminous flux at 35 °C

1200 lm

Number of lighting outlets

1

QT-FIT 5 2x14-35

Nominal current

0.14 A

Nominal wattage + Power loss

32.00 W

Power factor λ [PIM]

0.98

Luminous flux at 35 °C

1200 lm

Number of lighting outlets

2

QT-FIT 5 3x14, 4x14

Nominal current

0.28 A

Nominal wattage + Power loss

63.00 W

Power factor λ [PIM]

0.98

Luminous flux at 35 °C

1200 lm

Number of lighting outlets

4

QTi 1x14/24/21/39 GII

Nominal current

0.08 A

Nominal wattage + Power loss

16.00 W

Power factor λ [PIM]

0.92 c

Luminous flux at 35 °C

1200 lm

Number of lighting outlets

1

ECG_1.1 Ambient temperature for lifespan

40 °C

ECG_1.2 Ambient temperature for lifespan

50 °C

ECG_1.3 Ambient temperature for lifespan

60 °C

ECG_2.1 Tc point temperature for lifespa

45 °C

ECG_2.2 Tc point temperature for lifespa

55 °C

ECG_2.3 Tc point temperature for lifespa

65 °C

ECG_3.1 Temperature dependent lifespan

100000 h

ECG_3.2 Temperature dependent lifespan

100000 h

ECG_3.3 Temperature dependent lifespan

100000 h

QTi 1x14/24 DIM

Nominal current

0.07 A

Nominal wattage + Power loss

15.40 W

Power factor λ [PIM]

0.96

Luminous flux at 35 °C

1200 lm

Ambient temperature range [PIM] REM

Operation at up to -20 °C for all QTi (DALI) DIM-ECG possible. Lowest dimming position must be limited. Details see technical dimming brochure.

Number of lighting outlets

1

QTi 1x28/54/35/49 GII

Nominal current

0.08 A

Nominal wattage + Power loss

16.00 W

Power factor λ [PIM]

0.93 c

Luminous flux at 35 °C

1275 lm

Number of lighting outlets

1

QTi 1x35/49/80 GII

Nominal current

0.08 A

Nominal wattage + Power loss

16.00 W

Power factor λ [PIM]

0.93 c

Luminous flux at 35 °C

1275 lm

Number of lighting outlets

1

QTi 2x14/24/21/39 GII

Nominal current

0.15 A

Nominal wattage + Power loss

31.00 W

Power factor λ [PIM]

0.95

Luminous flux at 35 °C

1200 lm

Number of lighting outlets

2

ECG_1.1 Ambient temperature for lifespan

40 °C

ECG_1.2 Ambient temperature for lifespan

50 °C

ECG_1.3 Ambient temperature for lifespan

60 °C

ECG_2.1 Tc point temperature for lifespa

50 °C

ECG_2.2 Tc point temperature for lifespa

60 °C

ECG_2.3 Tc point temperature for lifespa

70 °C

ECG_3.1 Temperature dependent lifespan

100000 h

ECG_3.2 Temperature dependent lifespan

100000 h

ECG_3.3 Temperature dependent lifespan

80000 h

QTi 2x14/24 DIM

Nominal current

0.14 A

Nominal wattage + Power loss

30.60 W

Power factor λ [PIM]

0.96

Luminous flux at 35 °C

1200 lm

Ambient temperature range [PIM] REM

Operation at up to -20 °C for all QTi (DALI) DIM-ECG possible. Lowest dimming position must be limited. Details see technical dimming brochure.

Number of lighting outlets

2

QTi 2x28/54/35/49 GII

Nominal current

0.15 A

Nominal wattage + Power loss

32.00 W

Power factor λ [PIM]

0.93 c

Luminous flux at 35 °C

1275 lm

Number of lighting outlets

2

QTi 2x35/49/80 GII

Nominal current

0.18 A

Nominal wattage + Power loss

34.00 W

Power factor λ [PIM]

0.95

Luminous flux at 35 °C

1250 lm

Number of lighting outlets

2

QTi 3x14/24 DIM

Nominal current

0.20 A

Nominal wattage + Power loss

45.30 W

Power factor λ [PIM]

0.97

Luminous flux at 35 °C

1200 lm

Ambient temperature range [PIM] REM

Operation at up to -20 °C for all QTi (DALI) DIM-ECG possible. Lowest dimming position must be limited. Details see technical dimming brochure.

Number of lighting outlets

3

QTi 4x14/24 DIM

Nominal current

0.27 A

Nominal wattage + Power loss

60.40 W

Power factor λ [PIM]

0.97

Luminous flux at 35 °C

1200 lm

Ambient temperature range [PIM] REM

Operation at up to -20 °C for all QTi (DALI) DIM-ECG possible. Lowest dimming position must be limited. Details see technical dimming brochure.

Number of lighting outlets

4

QTi DALI 1x14/24 DIM

Nominal current

0.07 A

Nominal wattage + Power loss

15.40 W

Power factor λ [PIM]

0.95

Luminous flux at 35 °C

1200 lm

Ambient temperature range [PIM] REM

Operation at up to -20 °C for all QTi (DALI) DIM-ECG possible. Lowest dimming position must be limited. Details see technical dimming brochure.

Number of lighting outlets

1

ECG_1.1 Ambient temperature for lifespan

40 °C

ECG_1.2 Ambient temperature for lifespan

50 °C

ECG_1.3 Ambient temperature for lifespan

60 °C

ECG_2.1 Tc point temperature for lifespa

45 °C

ECG_2.2 Tc point temperature for lifespa

55 °C

ECG_2.3 Tc point temperature for lifespa

65 °C

ECG_3.1 Temperature dependent lifespan

100000 h

ECG_3.2 Temperature dependent lifespan

100000 h

ECG_3.3 Temperature dependent lifespan

100000 h

QTi DALI 2x14/24 DIM

Nominal current

0.14 A

Nominal wattage + Power loss

30.60 W

Power factor λ [PIM]

0.95

Luminous flux at 35 °C

1200 lm

Ambient temperature range [PIM] REM

Operation at up to -20 °C for all QTi (DALI) DIM-ECG possible. Lowest dimming position must be limited. Details see technical dimming brochure.

Number of lighting outlets

2

ECG_1.1 Ambient temperature for lifespan

40 °C

ECG_1.2 Ambient temperature for lifespan

50 °C

ECG_1.3 Ambient temperature for lifespan

60 °C

ECG_2.1 Tc point temperature for lifespa

50 °C

ECG_2.2 Tc point temperature for lifespa

60 °C

ECG_2.3 Tc point temperature for lifespa

70 °C

ECG_3.1 Temperature dependent lifespan

100000 h

ECG_3.2 Temperature dependent lifespan

100000 h

ECG_3.3 Temperature dependent lifespan

100000 h

QTi DALI 3x14/24 DIM

Nominal current

0.20 A

Nominal wattage + Power loss

45.30 W

Power factor λ [PIM]

0.97

Luminous flux at 35 °C

1200 lm

Ambient temperature range [PIM] REM

Operation at up to -20 °C for all QTi (DALI) DIM-ECG possible. Lowest dimming position must be limited. Details see technical dimming brochure.

Number of lighting outlets

3

ECG_1.1 Ambient temperature for lifespan

40 °C

ECG_1.2 Ambient temperature for lifespan

50 °C

ECG_1.3 Ambient temperature for lifespan

60 °C

ECG_2.1 Tc point temperature for lifespa

50 °C

ECG_2.2 Tc point temperature for lifespa

60 °C

ECG_2.3 Tc point temperature for lifespa

70 °C

ECG_3.1 Temperature dependent lifespan

100000 h

ECG_3.2 Temperature dependent lifespan

100000 h

ECG_3.3 Temperature dependent lifespan

100000 h

QTi DALI 4x14/24 DIM

Nominal current

0.27 A

Nominal wattage + Power loss

60.40 W

Power factor λ [PIM]

0.97

Luminous flux at 35 °C

1200 lm

Ambient temperature range [PIM] REM

Operation at up to -20 °C for all QTi (DALI) DIM-ECG possible. Lowest dimming position must be limited. Details see technical dimming brochure.

Number of lighting outlets

4

ECG_1.1 Ambient temperature for lifespan

40 °C

ECG_1.2 Ambient temperature for lifespan

50 °C

ECG_1.3 Ambient temperature for lifespan

60 °C

ECG_2.1 Tc point temperature for lifespa

55 °C

ECG_2.2 Tc point temperature for lifespa

65 °C

ECG_2.3 Tc point temperature for lifespa

75 °C

ECG_3.1 Temperature dependent lifespan

100000 h

ECG_3.2 Temperature dependent lifespan

100000 h

ECG_3.3 Temperature dependent lifespan

90000 h

QTP5 1x14-35

Nominal current

0.08 A

Nominal wattage + Power loss

16.00 W

Power factor λ [PIM]

0.90 c

Luminous flux at 35 °C

1200 lm

Number of lighting outlets

1

QTP5 2x14-35

Nominal current

0.14 A

Nominal wattage + Power loss

30.00 W

Power factor λ [PIM]

0.98

Luminous flux at 35 °C

1200 lm

Number of lighting outlets

2

QTP5 3x14, 4x14

Nominal current

0.22 A

Nominal wattage + Power loss

63.00 W

Power factor λ [PIM]

0.97

Luminous flux at 25 °C

1200 lm

Luminous flux at 35 °C

1350 lm

Number of lighting outlets

4

QTP5 3x14, 4x14

Nominal current

0.28 A

Nominal wattage + Power loss

48.00 W

Power factor λ [PIM]

0.95

Luminous flux at 25 °C

1200 lm

Luminous flux at 35 °C

1350 lm

Number of lighting outlets

3

Information about Family

Ecodesign regulation information:
Separate control gear and light sources must be disposed of at certified disposal companies in accordance with Directive 2012/19/EU (WEEE) in the EU and with Waste Electrical and Electronic Equipment (WEEE) Regulations 2013 in the UK. For this purpose, collection points for recycling centres and take-back systems (CRSO) are available from retailers or private disposal companies, which accept separate control gear and light sources free of charge. In this way, raw materials are conserved and materials are recycled.

Products

Sort by:
Product
Nominal wattage
Nominal luminous flux
Color temperature
Dimmable
Data sheet
HE 14 W/827
14.00 W 1200 lm 2700 K Yes
HE 14 W/830
13.90 W 1350 lm 3000 K Yes
HE 14 W/840
HE 21 W/830
HE 21 W/840
HE 21 W/865
21.00 W 1750 lm 6500 K Yes
HE 28 W/830
HE 28 W/840
HE 28 W/865
HE 35 W/830
HE 35 W/840