Digital Systems
 

HO 54 W/840

• Excellent luminous flux • Up to 20 % more economical than LUMILUX T8 • Up to 50 % smaller volume than comparable T8 lamps
• Industry • Public buildings • Offices • Tunnels, underpasses • Car parks • Outdoor applications only in suitable luminaires

References / Links
For more information on the system guarantee and the terms and conditions of the guarantee visit www.osram.com/system-guarantee

484426_Tonne-de

Technical Data

Electrical data

Nominal voltage

120 V

Nominal wattage

54.00 W

Rated lamp efficacy (HF data 25 °C)

82 lm/W

Rated wattage

54.10 W

Photometrical data

Color rendering index Ra

≥80

Rated luminous flux

4450 lm

Luminous flux at

4450 lm

Luminous flux at

5000 lm

Light color

840

Rated color temperature

4000 K

Nominal luminous flux

4450 lm

Light color (designation)

LUMILUX Cool White

Rated LLMF at 2,000 h

0.95

Rated LLMF at 4,000 h

0.93

Rated LLMF at 6,000 h

0.92

Rated LLMF at 8,000 h

0.90

Rated LLMF at 12,000 h

0.90

Rated LLMF at 16,000 h

0.90

Rated LLMF at 20,000 h

0.89

Luminous flux

4450 lm

Color temperature

4000 K

Dimensions & weight

Tube diameter

16 mm

Length

1149 mm

Length with base excl. base pins/connection

1149.00 mm

Diameter

16.0 mm

Product weight

90.00 g

Outer bulb

T16

Maximum diameter

16.0 mm

Temperatures & operating conditions

Rated ambient temp.w.max.luminous flux

35.0 °C

Lifespan

Service life

19000 h

With preheat ECG

Lifespan

24000 h

With preheat ECG

Rated lamp survival factor at 2,000 h

0.99

Rated lamp survival factor at 4,000 h

0.99

Rated lamp survival factor at 6,000 h

0.99

Rated lamp survival factor at 8,000 h

0.99

Rated lamp survival factor at 12,000 h

0.99

Rated lamp survival factor at 16,000 h

0.97

Rated lamp survival factor at 20,000 h

0.85

Operation mode LLMF/LSF

HF

Rated lamp life time

24000 h

Additional product data

Base (standard designation)

G5

Mercury content

1.7 mg

Product remark

Suitable for ECG operation only/Lamp designed for internal luminaire temperatures of 30…40 °C; optimum luminous flux achieved at 35 °C

Appropriate disposal acc. to WEEE

Yes

Capabilities

Dimmable

Yes

Suitable for indoor

Yes

Certificates & standards

Energy consumption

60 kWh/1000h

Energy efficiency class

A+

Country specific categorizations

Order reference

HO 54W/840

Packaging information

EAN

Unit

Piece

Dimension l x w x h

Weight

Volume

4050300453392 UNV

Unpacked

1 94.00g
4050300591582 FLH

Sleeve

1 132.00g
4050300453408 VS

Shipping box

40 1200mm x 83mm x 194mm 4713.00g 19.32dm³
4050300591599 VS

Shipping box

20 1182mm x 83mm x 91mm 2662.50g 8.93dm³

Downloads

Lamp-ECG Combination
QT-FIT 5/8 1x54-58

Nominal current

0.25 A

Nominal wattage + Power loss

59.00 W

Power factor λ [PIM]

0.98

Luminous flux at 35 °C

4450 lm

Number of lighting outlets

1

ECG_1.1 Ambient temperature for lifespan

40 °C

ECG_1.2 Ambient temperature for lifespan

50 °C

ECG_1.3 Ambient temperature for lifespan

60 °C

ECG_2.1 Tc point temperature for lifespa

50 °C

ECG_2.2 Tc point temperature for lifespa

60 °C

ECG_2.3 Tc point temperature for lifespa

70 °C

ECG_3.1 Temperature dependent lifespan

100000 h

ECG_3.2 Temperature dependent lifespan

80000 h

ECG_3.3 Temperature dependent lifespan

50000 h

QT-FIT 5/8 2x54-58

Nominal current

0.49 A

Nominal wattage + Power loss

116.00 W

Power factor λ [PIM]

0.98

Luminous flux at 35 °C

4450 lm

Number of lighting outlets

2

ECG_1.1 Ambient temperature for lifespan

40 °C

ECG_1.2 Ambient temperature for lifespan

50 °C

ECG_1.3 Ambient temperature for lifespan

55 °C

ECG_2.1 Tc point temperature for lifespa

65 °C

ECG_2.2 Tc point temperature for lifespa

75 °C

ECG_2.3 Tc point temperature for lifespa

75 °C

ECG_3.1 Temperature dependent lifespan

60000 h

ECG_3.2 Temperature dependent lifespan

30000 h

ECG_3.3 Temperature dependent lifespan

30000 h

QTi 1x28/54/35/49 GII

Nominal current

0.26 A

Nominal wattage + Power loss

58.00 W

Power factor λ [PIM]

0.97

Luminous flux at 35 °C

4450 lm

Number of lighting outlets

1

ECG_1.1 Ambient temperature for lifespan

40 °C

ECG_1.2 Ambient temperature for lifespan

50 °C

ECG_1.3 Ambient temperature for lifespan

60 °C

ECG_2.1 Tc point temperature for lifespa

50 °C

ECG_2.2 Tc point temperature for lifespa

60 °C

ECG_2.3 Tc point temperature for lifespa

70 °C

ECG_3.1 Temperature dependent lifespan

100000 h

ECG_3.2 Temperature dependent lifespan

100000 h

ECG_3.3 Temperature dependent lifespan

80000 h

QTi 1x28/54 DIM

Nominal current

0.26 A

Nominal wattage + Power loss

58.80 W

Power factor λ [PIM]

0.99

Luminous flux at 35 °C

4450 lm

Ambient temperature range [PIM] REM

Operation at up to -20 °C for all QTi (DALI) DIM-ECG possible. Lowest dimming position must be limited. Details see technical dimming brochure.

Number of lighting outlets

1

QTi 2x28/54/35/49 GII

Nominal current

0.51 A

Nominal wattage + Power loss

115.00 W

Power factor λ [PIM]

0.98

Luminous flux at 35 °C

4450 lm

Number of lighting outlets

2

ECG_1.1 Ambient temperature for lifespan

40 °C

ECG_1.2 Ambient temperature for lifespan

50 °C

ECG_1.3 Ambient temperature for lifespan

59 °C

ECG_2.1 Tc point temperature for lifespa

60 °C

ECG_2.2 Tc point temperature for lifespa

70 °C

ECG_2.3 Tc point temperature for lifespa

75 °C

ECG_3.1 Temperature dependent lifespan

100000 h

ECG_3.2 Temperature dependent lifespan

100000 h

ECG_3.3 Temperature dependent lifespan

50000 h

QTi 2x28/54 DIM

Nominal current

0.51 A

Nominal wattage + Power loss

115.00 W

Power factor λ [PIM]

0.98

Luminous flux at 35 °C

4450 lm

Ambient temperature range [PIM] REM

Operation at up to -20 °C for all QTi (DALI) DIM-ECG possible. Lowest dimming position must be limited. Details see technical dimming brochure.

Number of lighting outlets

2

QTi DALI 1x28/54 DIM

Nominal current

0.26 A

Nominal wattage + Power loss

58.80 W

Power factor λ [PIM]

0.99

Luminous flux at 35 °C

4450 lm

Ambient temperature range [PIM] REM

Operation at up to -20 °C for all QTi (DALI) DIM-ECG possible. Lowest dimming position must be limited. Details see technical dimming brochure.

Number of lighting outlets

1

ECG_1.1 Ambient temperature for lifespan

40 °C

ECG_1.2 Ambient temperature for lifespan

50 °C

ECG_1.3 Ambient temperature for lifespan

60 °C

ECG_2.1 Tc point temperature for lifespa

50 °C

ECG_2.2 Tc point temperature for lifespa

60 °C

ECG_2.3 Tc point temperature for lifespa

70 °C

ECG_3.1 Temperature dependent lifespan

100000 h

ECG_3.2 Temperature dependent lifespan

100000 h

ECG_3.3 Temperature dependent lifespan

100000 h

QTi DALI 2x28/54 DIM

Nominal current

0.51 A

Nominal wattage + Power loss

115.00 W

Power factor λ [PIM]

0.99

Luminous flux at 35 °C

4450 lm

Ambient temperature range [PIM] REM

Operation at up to -20 °C for all QTi (DALI) DIM-ECG possible. Lowest dimming position must be limited. Details see technical dimming brochure.

Number of lighting outlets

2

ECG_1.1 Ambient temperature for lifespan

40 °C

ECG_1.2 Ambient temperature for lifespan

50 °C

ECG_1.3 Ambient temperature for lifespan

60 °C

ECG_2.1 Tc point temperature for lifespa

55 °C

ECG_2.2 Tc point temperature for lifespa

65 °C

ECG_2.3 Tc point temperature for lifespa

75 °C

ECG_3.1 Temperature dependent lifespan

100000 h

ECG_3.2 Temperature dependent lifespan

100000 h

ECG_3.3 Temperature dependent lifespan

90000 h

QTP-OPTIMAL 1x54-58

Nominal current

0.26 A

Nominal wattage + Power loss

54.00 W

Power factor λ [PIM]

0.98

Luminous flux at 35 °C

4450 lm

Number of lighting outlets

1

QTP-OPTIMAL 2x54-58

Nominal current

0.52 A

Nominal wattage + Power loss

120.00 W

Power factor λ [PIM]

0.99

Luminous flux at 35 °C

4450 lm

Number of lighting outlets

2

ECG_1.1 Ambient temperature for lifespan

40 °C

ECG_1.2 Ambient temperature for lifespan

50 °C

ECG_1.3 Ambient temperature for lifespan

60 °C

ECG_2.1 Tc point temperature for lifespa

60 °C

ECG_2.2 Tc point temperature for lifespa

65 °C

ECG_2.3 Tc point temperature for lifespa

75 °C

ECG_3.1 Temperature dependent lifespan

100000 h

ECG_3.2 Temperature dependent lifespan

90000 h

ECG_3.3 Temperature dependent lifespan

50000 h

Products

Sort by:
Product
Nominal wattage
Nominal luminous flux
Color temperature
Dimmable
Data sheet
HO 24 W/827
24.00 W 1750 lm 2700 K Yes
HO 24 W/830
24.00 W 1750 lm 3000 K Yes
HO 24 W/840
24.00 W 1750 lm 4000 K Yes
HO 24 W/865
24.00 W 1600 lm 6500 K Yes
HO 39 W/827
38.00 W 3100 lm 2700 K Yes
HO 39 W/830
HO 39 W/840
38.00 W 3100 lm 4000 K Yes
HO 39 W/865
38.00 W 2850 lm 6500 K Yes
HO 49 W/827
49.00 W 4310 lm 2700 K Yes
HO 49 W/830
49.00 W 4310 lm 3000 K Yes
HO 49 W/840
49.00 W 4310 lm 4000 K Yes
HO 49 W/865
49.00 W 4100 lm 6500 K Yes
HO 54 W/827
54.00 W 4450 lm 2700 K Yes
HO 54 W/830
54.00 W 4450 lm 3000 K Yes
HO 54 W/840
54.00 W 4450 lm 4000 K Yes
HO 54 W/865
54.00 W 4100 lm 6500 K Yes
HO 80 W/830
80.00 W 6150 lm 3000 K Yes
HO 80 W/840
80.00 W 6150 lm 4000 K Yes
HO 80 W/865
80.00 W 5700 lm 6500 K Yes