HO 49 W/830

References / Links
For more information on the system guarantee and the terms and conditions of the guarantee visit https://www.inventronics-light.com/multilevel-guarantees

Technical Data

Electrical data

Nominal current

0.26 A A

Photometrical data

Luminous flux at

4800 lm

Light color (designation)

LUMILUX Warm White

Rated LLMF at 2,000 h

0.95

Rated LLMF at 4,000 h

0.93

Rated LLMF at 6,000 h

0.92

Rated LLMF at 8,000 h

0.9

Rated LLMF at 12,000 h

0.9

Rated LLMF at 16,000 h

0.9

Rated LLMF at 20,000 h

0.89

Luminous flux

4800 lm

Dimensions & weight

Tube diameter

16 mm

Length with base excl. base pins/connection

1449 mm

Overall length

1463.20 mm

Product weight

116.45 g

Lifespan

Service life

19000 h

Additional product data

Mercury content

2.0 mg

Product remark

Suitable for ECG operation only | Lamp designed for internal luminaire temperatures of 30…40 °C; optimum luminous flux achieved at 35 °C

Appropriate disposal acc. to WEEE

Yes

Certificates & standards

Energy efficiency class

F

Energy consumption

50.00 kWh/1000h

Environmental information


Information according Art. 33 of EU Regulation (EC) 1907/2006 (REACh)

Date of Declaration

18-04-2022

Primary Article Identifier

4050300657158

Declaration No. in SCIP database

In work

Packaging information

EAN

Unit

Piece

Dimension l x w x h

Weight

Volume

4050300657158 UNV

Unpacked

1 115.00g
4050300657165 VS

Shipping box

40 1498mm x 161mm x 103mm 6525.00g 24.84dm³

Downloads

Lamp-ECG Combination
QT-FIT 5 1x49

Nominal current

0.24 A

Nominal wattage + Power loss

54.00 W

Power factor λ [PIM]

0.98

Luminous flux at 35 °C

4300 lm

Number of lighting outlets

1

ECG_1.1 Ambient temperature for lifespan

40 °C

ECG_1.2 Ambient temperature for lifespan

50 °C

ECG_1.3 Ambient temperature for lifespan

60 °C

ECG_2.1 Tc point temperature for lifespa

55 °C

ECG_2.2 Tc point temperature for lifespa

60 °C

ECG_2.3 Tc point temperature for lifespa

70 °C

ECG_3.1 Temperature dependent lifespan

100000 h

ECG_3.2 Temperature dependent lifespan

100000 h

ECG_3.3 Temperature dependent lifespan

70000 h

QT-FIT 5 2x49

Nominal current

0.47 A

Nominal wattage + Power loss

106.00 W

Power factor λ [PIM]

0.98

Luminous flux at 35 °C

4300 lm

Number of lighting outlets

2

ECG_1.1 Ambient temperature for lifespan

40 °C

ECG_1.2 Ambient temperature for lifespan

50 °C

ECG_1.3 Ambient temperature for lifespan

56 °C

ECG_2.1 Tc point temperature for lifespa

65 °C

ECG_2.2 Tc point temperature for lifespa

70 °C

ECG_2.3 Tc point temperature for lifespa

75 °C

ECG_3.1 Temperature dependent lifespan

100000 h

ECG_3.2 Temperature dependent lifespan

40000 h

ECG_3.3 Temperature dependent lifespan

50000 h

QTi 1x28/54/35/49 GII

Nominal current

0.24 A

Nominal wattage + Power loss

53.00 W

Power factor λ [PIM]

0.97

Luminous flux at 35 °C

4300 lm

Number of lighting outlets

1

ECG_1.1 Ambient temperature for lifespan

40 °C

ECG_1.2 Ambient temperature for lifespan

50 °C

ECG_1.3 Ambient temperature for lifespan

60 °C

ECG_2.1 Tc point temperature for lifespa

50 °C

ECG_2.2 Tc point temperature for lifespa

55 °C

ECG_2.3 Tc point temperature for lifespa

65 °C

ECG_3.1 Temperature dependent lifespan

100000 h

ECG_3.2 Temperature dependent lifespan

100000 h

ECG_3.3 Temperature dependent lifespan

90000 h

QTi 1x35/49/80 GII

Nominal current

0.24 A

Nominal wattage + Power loss

53.00 W

Power factor λ [PIM]

0.97

Luminous flux at 35 °C

4300 lm

Number of lighting outlets

1

ECG_1.1 Ambient temperature for lifespan

40 °C

ECG_1.2 Ambient temperature for lifespan

50 °C

ECG_1.3 Ambient temperature for lifespan

60 °C

ECG_2.1 Tc point temperature for lifespa

50 °C

ECG_2.2 Tc point temperature for lifespa

55 °C

ECG_2.3 Tc point temperature for lifespa

65 °C

ECG_3.1 Temperature dependent lifespan

100000 h

ECG_3.2 Temperature dependent lifespan

100000 h

ECG_3.3 Temperature dependent lifespan

100000 h

QTi 2x28/54/35/49 GII

Nominal current

0.46 A

Nominal wattage + Power loss

105.00 W

Power factor λ [PIM]

0.98

Luminous flux at 35 °C

4300 lm

Number of lighting outlets

2

ECG_1.1 Ambient temperature for lifespan

40 °C

ECG_1.2 Ambient temperature for lifespan

50 °C

ECG_1.3 Ambient temperature for lifespan

60 °C

ECG_2.1 Tc point temperature for lifespa

55 °C

ECG_2.2 Tc point temperature for lifespa

65 °C

ECG_2.3 Tc point temperature for lifespa

70 °C

ECG_3.1 Temperature dependent lifespan

100000 h

ECG_3.2 Temperature dependent lifespan

100000 h

ECG_3.3 Temperature dependent lifespan

70000 h

QTi 2x35/49/80 GII

Nominal current

0.45 A

Nominal wattage + Power loss

105.00 W

Power factor λ [PIM]

0.99

Luminous flux at 35 °C

4300 lm

Number of lighting outlets

2

ECG_1.1 Ambient temperature for lifespan

40 °C

ECG_1.2 Ambient temperature for lifespan

50 °C

ECG_1.3 Ambient temperature for lifespan

60 °C

ECG_2.1 Tc point temperature for lifespa

55 °C

ECG_2.2 Tc point temperature for lifespa

65 °C

ECG_2.3 Tc point temperature for lifespa

70 °C

ECG_3.1 Temperature dependent lifespan

100000 h

ECG_3.2 Temperature dependent lifespan

100000 h

ECG_3.3 Temperature dependent lifespan

60000 h

QTi DALI 2x35/49 DIM

Nominal current

0.45 A

Nominal wattage + Power loss

103.60 W

Power factor λ [PIM]

0.99

Luminous flux at 35 °C

4300 lm

Ambient temperature range [PIM] REM

Operation at up to -20 °C for all QTi (DALI) DIM-ECG possible. Lowest dimming position must be limited. Details see technical dimming brochure.

Number of lighting outlets

2

ECG_1.1 Ambient temperature for lifespan

40 °C

ECG_1.2 Ambient temperature for lifespan

50 °C

ECG_1.3 Ambient temperature for lifespan

60 °C

ECG_2.1 Tc point temperature for lifespa

55 °C

ECG_2.2 Tc point temperature for lifespa

65 °C

ECG_2.3 Tc point temperature for lifespa

75 °C

ECG_3.1 Temperature dependent lifespan

100000 h

ECG_3.2 Temperature dependent lifespan

100000 h

ECG_3.3 Temperature dependent lifespan

90000 h

QTP5 1x49

Nominal current

0.24 A

Nominal wattage + Power loss

53.00 W

Power factor λ [PIM]

0.95

Number of lighting outlets

1

ECG_1.1 Ambient temperature for lifespan

40 °C

ECG_1.2 Ambient temperature for lifespan

50 °C

ECG_1.3 Ambient temperature for lifespan

60 °C

ECG_2.1 Tc point temperature for lifespa

55 °C

ECG_2.2 Tc point temperature for lifespa

60 °C

ECG_2.3 Tc point temperature for lifespa

70 °C

ECG_3.1 Temperature dependent lifespan

100000 h

ECG_3.2 Temperature dependent lifespan

100000 h

ECG_3.3 Temperature dependent lifespan

70000 h

QTP5 1x49

Nominal current

0.24 A

Nominal wattage + Power loss

53.00 W

Power factor λ [PIM]

0.95

Luminous flux at 35 °C

4300 lm

Number of lighting outlets

1

ECG_1.1 Ambient temperature for lifespan

40 °C

ECG_1.2 Ambient temperature for lifespan

50 °C

ECG_1.3 Ambient temperature for lifespan

60 °C

ECG_2.1 Tc point temperature for lifespa

55 °C

ECG_2.2 Tc point temperature for lifespa

60 °C

ECG_2.3 Tc point temperature for lifespa

70 °C

ECG_3.1 Temperature dependent lifespan

100000 h

ECG_3.2 Temperature dependent lifespan

100000 h

ECG_3.3 Temperature dependent lifespan

70000 h

QTP5 2x49

Nominal current

0.49 A

Nominal wattage + Power loss

106.00 W

Power factor λ [PIM]

0.99

Number of lighting outlets

2

ECG_1.1 Ambient temperature for lifespan

40 °C

ECG_1.2 Ambient temperature for lifespan

50 °C

ECG_1.3 Ambient temperature for lifespan

60 °C

ECG_2.1 Tc point temperature for lifespa

60 °C

ECG_2.2 Tc point temperature for lifespa

65 °C

ECG_2.3 Tc point temperature for lifespa

75 °C

ECG_3.1 Temperature dependent lifespan

100000 h

ECG_3.2 Temperature dependent lifespan

80000 h

ECG_3.3 Temperature dependent lifespan

50000 h

QTP5 2x49

Nominal current

0.49 A

Nominal wattage + Power loss

106.00 W

Power factor λ [PIM]

0.99

Luminous flux at 35 °C

4300 lm

Number of lighting outlets

2

Information about Family

Ecodesign regulation information:
Separate control gear and light sources must be disposed of at certified disposal companies in accordance with Directive 2012/19/EU (WEEE) in the EU and with Waste Electrical and Electronic Equipment (WEEE) Regulations 2013 in the UK. For this purpose, collection points for recycling centres and take-back systems (CRSO) are available from retailers or private disposal companies, which accept separate control gear and light sources free of charge. In this way, raw materials are conserved and materials are recycled.

Products

Sort by:
Product
Nominal wattage
Nominal luminous flux
Color temperature
Overall length
Dimmable
Data sheet
HO 24 W/840
563.20 mm
HO 39 W/840
38.00 W 3100 lm 4000 K 863.20 mm Yes
HO 49 W/830
1463.20 mm
HO 49 W/840
1463.20 mm
HO 54 W/830
1163.20 mm
HO 54 W/840
1163.20 mm
HO 80 W/840
1463.20 mm