L 36 W/830

References / Links
For more information on the system guarantee and the terms and conditions of the guarantee visit https://www.inventronics-light.com/multilevel-guarantees
For more information on QUICKTRONIC electronic control gear go to www.osram.com/QUICKTRONIC

Technical Data

Electrical data

Nominal wattage

36.00 W

Rated lamp efficacy (HF data 25 °C)

Under clarification by authority and standardization body

Rated wattage

36.00 W

Nominal current

0.43 A A

Photometrical data

Rated lamp efficacy (standard condition)

93 lm/W

Color rendering index Ra

≥80

Rated luminous flux

3350 lm

Luminous flux at

3350 lm

Light color

830

Rated color temperature

3000 K

Nominal luminous flux

3350 lm

Light color (designation)

LUMILUX Warm White

Rated LLMF at 2,000 h

0.96

Rated LLMF at 4,000 h

0.94

Rated LLMF at 6,000 h

0.93

Rated LLMF at 8,000 h

0.91

Rated LLMF at 12,000 h

0.91

Rated LLMF at 16,000 h

0.90

Rated LLMF at 20,000 h

0.89

Luminous flux

3350 lm

Color temperature

3000 K

Dimensions & weight

Tube diameter

26 mm

Length

1200 mm

Length with base excl. base pins/connection

1200.00 mm

Diameter

26.0 mm

Product weight

149.00 g

Overall length

1213.60 mm

Outer bulb

T26

Maximum diameter

26.0 mm

Temperatures & operating conditions

Rated ambient temp.w.max.luminous flux

25.0 °C

Lifespan

Service life

18000 h

With preheat ECG

Lifespan

20000 h

With preheat ECG

Rated lamp survival factor at 2,000 h

0.99

Rated lamp survival factor at 4,000 h

0.99

Rated lamp survival factor at 6,000 h

0.99

Rated lamp survival factor at 8,000 h

0.99

Rated lamp survival factor at 12,000 h

0.99

Rated lamp survival factor at 16,000 h

0.99

Rated lamp survival factor at 20,000 h

0.50

Operation mode LLMF/LSF

HF

Rated lamp life time

20000 h

Additional product data

Base (standard designation)

G13

Mercury content

2.5 mg

Appropriate disposal acc. to WEEE

Yes

Successor EAN

4050300517896

Predecessor EAN

4050300443324

Capabilities

Dimmable

Yes

Suitable for indoor

Yes

Certificates & standards

Energy consumption

43 kWh/1000h

Energy efficiency class

G

Country specific categorizations

Order reference

L 36W/830

Environmental information


Information according Art. 33 of EU Regulation (EC) 1907/2006 (REACh)

Date of Declaration

19-01-2022

Primary Article Identifier

4050300443324 | 4050300517896

Declaration No. in SCIP database

In work

Packaging information

EAN

Unit

Piece

Dimension l x w x h

Weight

Volume

4050300517896 FLH

Sleeve

1
4050300517902 VS

Shipping box

25 144mm x 147mm x 1242mm 5535.00g 26.29dm³

Downloads

Lamp-ECG Combination
QT-FIT 5/8 1x18-39

Nominal current

0.16 A

Nominal wattage + Power loss

37.00 W

Power factor λ [PIM]

0.98

Luminous flux at 35 °C

3200 lm

Number of lighting outlets

1

ECG_1.1 Ambient temperature for lifespan

40 °C

ECG_1.2 Ambient temperature for lifespan

50 °C

ECG_1.3 Ambient temperature for lifespan

60 °C

ECG_2.1 Tc point temperature for lifespa

55 °C

ECG_2.2 Tc point temperature for lifespa

65 °C

ECG_2.3 Tc point temperature for lifespa

75 °C

ECG_3.1 Temperature dependent lifespan

100000 h

ECG_3.2 Temperature dependent lifespan

60000 h

ECG_3.3 Temperature dependent lifespan

40000 h

QT-FIT 5/8 2x18-39

Nominal current

0.31 A

Nominal wattage + Power loss

70.00 W

Power factor λ [PIM]

0.98

Luminous flux at 35 °C

3200 lm

Number of lighting outlets

2

ECG_1.1 Ambient temperature for lifespan

40 °C

ECG_1.2 Ambient temperature for lifespan

50 °C

ECG_1.3 Ambient temperature for lifespan

60 °C

ECG_2.1 Tc point temperature for lifespa

55 °C

ECG_2.2 Tc point temperature for lifespa

65 °C

ECG_2.3 Tc point temperature for lifespa

75 °C

ECG_3.1 Temperature dependent lifespan

100000 h

ECG_3.2 Temperature dependent lifespan

60000 h

ECG_3.3 Temperature dependent lifespan

30000 h

QT-FIT8 1x36

Nominal current

0.16 A

Nominal wattage + Power loss

36.00 W

Power factor λ [PIM]

0.96

Luminous flux at 35 °C

3200 lm

Number of lighting outlets

1

ECG_1.1 Ambient temperature for lifespan

40 °C

ECG_1.2 Ambient temperature for lifespan

50 °C

ECG_1.3 Ambient temperature for lifespan

60 °C

ECG_2.1 Tc point temperature for lifespa

50 °C

ECG_2.2 Tc point temperature for lifespa

60 °C

ECG_2.3 Tc point temperature for lifespa

65 °C

ECG_3.1 Temperature dependent lifespan

100000 h

ECG_3.2 Temperature dependent lifespan

100000 h

ECG_3.3 Temperature dependent lifespan

70000 h

QT-FIT8 2x36

Nominal current

0.32 A

Nominal wattage + Power loss

71.00 W

Power factor λ [PIM]

0.98

Luminous flux at 35 °C

3200 lm

Number of lighting outlets

2

ECG_1.1 Ambient temperature for lifespan

40 °C

ECG_1.2 Ambient temperature for lifespan

50 °C

ECG_1.3 Ambient temperature for lifespan

60 °C

ECG_2.1 Tc point temperature for lifespa

55 °C

ECG_2.2 Tc point temperature for lifespa

60 °C

ECG_2.3 Tc point temperature for lifespa

70 °C

ECG_3.1 Temperature dependent lifespan

100000 h

ECG_3.2 Temperature dependent lifespan

90000 h

ECG_3.3 Temperature dependent lifespan

50000 h

QT-FIT8 3x36

Nominal current

0.48 A

Nominal wattage + Power loss

105.00 W

Power factor λ [PIM]

0.99

Luminous flux at 35 °C

3500 lm

Number of lighting outlets

3

QTi 2x14/24/21/39 GII

Nominal current

0.31 A

Nominal wattage + Power loss

70.00 W

Power factor λ [PIM]

0.98

Luminous flux at 35 °C

3200 lm

Number of lighting outlets

2

QT-M 2x26-42/220-240 S

Nominal current

0.30 A

Nominal wattage + Power loss

70.00 W

Power factor λ [PIM]

0.97

Luminous flux at 35 °C

3200 lm

Number of lighting outlets

2

QTP-DL 2x36-40

Nominal current

0.35 A

Nominal wattage + Power loss

80.50 W

Power factor λ [PIM]

0.99

Luminous flux at 35 °C

3400 lm

Number of lighting outlets

2

QTP-M 1x26-42

Nominal current

0.16 A

Nominal wattage + Power loss

35.00 W

Power factor λ [PIM]

0.97

Luminous flux at 35 °C

3350 lm

Number of lighting outlets

1

QTP-OPTIMAL 1x18-40

Nominal current

0.16 A

Nominal wattage + Power loss

36.00 W

Power factor λ [PIM]

0.98

Luminous flux at 35 °C

3200 lm

Number of lighting outlets

1

ECG_1.1 Ambient temperature for lifespan

40 °C

ECG_1.2 Ambient temperature for lifespan

50 °C

ECG_1.3 Ambient temperature for lifespan

60 °C

ECG_2.1 Tc point temperature for lifespa

55 °C

ECG_2.2 Tc point temperature for lifespa

60 °C

ECG_2.3 Tc point temperature for lifespa

70 °C

ECG_3.1 Temperature dependent lifespan

100000 h

ECG_3.2 Temperature dependent lifespan

100000 h

ECG_3.3 Temperature dependent lifespan

80000 h

QTP-OPTIMAL 2x18-40

Nominal current

0.30 A

Nominal wattage + Power loss

71.00 W

Power factor λ [PIM]

0.98

Luminous flux at 35 °C

3200 lm

Number of lighting outlets

2

ECG_1.1 Ambient temperature for lifespan

40 °C

ECG_1.2 Ambient temperature for lifespan

50 °C

ECG_1.3 Ambient temperature for lifespan

60 °C

ECG_2.1 Tc point temperature for lifespa

55 °C

ECG_2.2 Tc point temperature for lifespa

65 °C

ECG_2.3 Tc point temperature for lifespa

70 °C

ECG_3.1 Temperature dependent lifespan

100000 h

ECG_3.2 Temperature dependent lifespan

100000 h

ECG_3.3 Temperature dependent lifespan

70000 h

QTz8 1x36

Nominal current

0.16 A

Nominal wattage + Power loss

36.00 W

Power factor λ [PIM]

0.96

Luminous flux at 35 °C

3200 lm

Number of lighting outlets

1

ECG_1.3 Ambient temperature for lifespan

50 °C

ECG_2.3 Tc point temperature for lifespa

75 °C

ECG_3.3 Temperature dependent lifespan

30000 h

QTz8 2x36

Nominal current

0.32 A

Nominal wattage + Power loss

71.00 W

Power factor λ [PIM]

0.98

Luminous flux at 35 °C

3200 lm

Number of lighting outlets

2

ECG_1.1 Ambient temperature for lifespan

50 °C

ECG_1.2 Ambient temperature for lifespan

50 °C

ECG_1.3 Ambient temperature for lifespan

50 °C

ECG_2.1 Tc point temperature for lifespa

60 °C

ECG_2.2 Tc point temperature for lifespa

70 °C

ECG_2.3 Tc point temperature for lifespa

75 °C

ECG_3.1 Temperature dependent lifespan

100000 h

ECG_3.2 Temperature dependent lifespan

80000 h

ECG_3.3 Temperature dependent lifespan

30000 h

Information about Family

Ecodesign regulation information:
Separate control gear and light sources must be disposed of at certified disposal companies in accordance with Directive 2012/19/EU (WEEE) in the EU and with Waste Electrical and Electronic Equipment (WEEE) Regulations 2013 in the UK. For this purpose, collection points for recycling centres and take-back systems (CRSO) are available from retailers or private disposal companies, which accept separate control gear and light sources free of charge. In this way, raw materials are conserved and materials are recycled.

Products

Sort by:
Product
Nominal wattage
Nominal luminous flux
Color temperature
Overall length
Dimmable
Data sheet
L 15 W/827
451.60 mm
L 15 W/830
451.60 mm
L 15 W/840
451.60 mm
L 15 W/865
451.60 mm
L 16 W/830
734.20 mm
L 16 W/840
734.20 mm
L 18 W/840
604.00 mm
L 18 W/840
604.00 mm
L 23 W/840
984.20 mm
L 30 W/827
908.80 mm
L 30 W/830
908.80 mm
L 30 W/840
908.80 mm
L 36 W/830
36.00 W 3350 lm 3000 K 1213.60 mm Yes
L 36 W/840
1213.60 mm
L 36 W/880
1213.60 mm
L 38 W/840
1061.20 mm
L 58 W/830
1514.20 mm
L 58 W/840
1514.20 mm
L 58 W/865
1514.20 mm
L 58 W/880
1514.20 mm