OT 600/220...240/ 2A1 2DIM P7 AUX12
- Easily programmable by OT Programmer-S; (AstroDIM / Constant lumen)
- Efficient and reliable
- 2DIM functionality in one device (AstroDIM, 1 10 V)
- High surge protection: up to 10 kV
- Great flexibility due to wide operating temperature range of -40 55 °C
- Lifetime: up to 100,000 h
- IP rating: IP67
- 5 years guarantee
- Area lighting
- Stadium lighting
- Horticulture lighting
- Street and urban lighting
- Suitable for luminaires of protection class I
References / Links
* For more information on the multi-level guarantee and the terms and conditions of the guarantee visit www.osram.com/system-guarantee
Technical Data
Electrical data
Nominal voltage
220 240 V
Input voltage AC
198 264 V
Nominal current
3.3 A
Mains frequency
50 60 Hz
Power factor λ
0.95
Total harmonic distortion
< 10 %
Device power loss
34 W
Inrush current
55 A
Max. ECG no. on circuit breaker 10 A (B)
1
Max. ECG no. on circuit breaker 16 A (B)
2
Max. ECG no. on circuit breaker 25 A (B)
3
Surge capability (L/N-Ground)
10 kV
Surge capability (L-N)
6 kV
Nominal output power
600 W
Maximum output power
600 W
Efficiency in full-load
94 %
Nominal output current
1750 2100 mA
Default output current
2100 mA
Output current tolerance
±5 %
Output ripple current (100 Hz)
6 %
Output PSTLM
≤1
Output SVM
≤0.4
Minimum output current
1750 mA
Galvanic isolation
basic
Nominal output voltage
225 343 V
Dimensions & weight
Length
261.0 mm
Width
125.0 mm
Height
43.5 mm
Mounting hole spacing, length
247.5 mm
Mounting hole spacing, width
78.0 mm
Product weight
2550.00 g
Cable cross-section, input side
1.0 mm²
Cable cross-section, output side
1.0 mm²
Wire preparation length, input side
10 mm
Temperatures & operating conditions
Ambient temperature range
-40 +55 °C
Temperature range at storage
-40 +85 °C
Maximum temperature at tc test point
90 °C
Max.housing temperature in case of fault
120 °C
Permitted rel. humidity during operation
5 85 %
Lifespan
ECG lifetime
50000 / 100000 h
Capabilities
Dimmable
Yes
Dimming interface
1 10 V / 2DIM
Dimming range
10 100 %
Suitable for fixtures with prot. class
I
Constant lumen function
Yes
Short-circuit protection
Yes
No-load proof
Yes
Intended for no-load operation
No
Max. cable length to lamp/LED module
2.0 m
Number of channels
1
Programming
Programming device
OT Programmer-S - EAN [4052899629172]
Certificates & standards
Type of protection
IP67
Standards
Acc. to EN 61347-1:2015/Acc. to EN 61347-1:2015/A1:2021/Acc. to EN 61347-2-13:2014/Acc. to EN 62384:2006/Acc. to EN 62384:2006/A1:2009/CB/CCC/ENEC
Approval marks approval
CCC / CE / ENEC / RCM / CB
Logistical data
Commodity code
850440839000
Environmental information
Information according Art. 33 of EU Regulation (EC) 1907/2006 (REACh)
Date of Declaration
05-05-2022
Primary Article Identifier
4052899624238
Candidate List Substance 1
Lead
CAS No. of substance 1
7439-92-1
Safe Use Instruction
The identification of the Candidate List substance is sufficient to allow safe use of the article.
Declaration No. in SCIP database
e19b7057-ee21-4be7-ae64-3e1fd9ee290f
Packaging information
EAN |
Unit |
Piece |
Dimension l x w x h |
Weight |
Volume |
---|---|---|---|---|---|
4052899624238 |
UNV
| 1 | 15300.00g | ||
4052899624252 |
VS
| 6 | 502mm x 392mm x 176mm | 16445.00g | 34.63dm³ |
Downloads
Data sheets
Information about Family
- Available with different wattage: 400 W, 600 W
- Supply voltage: 220 240 V
- AUX 12V output for sensor and wireless node
- Wide output current range
- Lifetime: up to 100,000 h (at T = 75 °C at Tc)
Intended for use with LED modules.
The forward voltage of the LED light source shall be within the defined operating window of the control gear in all operating conditions including dimming if applicable.
Separate control gear and light sources must be disposed of at certified disposal companies in accordance with Directive 2012/19/EU (WEEE) in the EU and with Waste Electrical and Electronic Equipment (WEEE) Regulations 2013 in the UK. For this purpose, collection points for recycling centres and take-back systems (CRSO) are available from retailers or private disposal companies, which accept separate control gear and light sources free of charge. In this way, raw materials are conserved and materials are recycled.
Products
Product |
|
|
|
|
Data sheet | ||
---|---|---|---|---|---|---|---|
![]() |
OT 600/220...240/ 2A1 2DIM P7 AUX12
|
1750 2100 mA | 261.0 mm | 125.0 mm | 43.5 mm | ||
![]() |
OT 400/220...240/ 1A4 2DIM P7 AUX12
|
1050 1400 mA | 252.0 mm | 89.5 mm | 44.5 mm |