OT 100 UNV 1A0 2DIM P7

Product family benefits
  • 2DIM functionality in one device (AstroDIM, 1…10 V)
  • High surge protection: up to 10 kV
  • High efficiency up to 92%
  • Great flexibility due to wide operating temperature range of -40…60 °C
  • IP rating: IP67
Areas of application
  • Street and urban lighting
  • Industry
  • Suitable for luminaires of protection class I
German innovation awards 2019 winner

Technical Data

Electrical data

Nominal voltage

120…240/277 V

Input voltage AC

90…305 V

Nominal current

0.55 A

Mains frequency

47…63 Hz

Power factor λ

0.95

Full load at 230 V/50 Hz

Total harmonic distortion

< 10 %

Device power loss

8.5 W

Inrush current

52 A

Max. ECG no. on circuit breaker 10 A (B)

3

Max. ECG no. on circuit breaker 16 A (B)

6

Max. ECG no. on circuit breaker 25 A (B)

9

Surge capability (L/N-Ground)

10 kV

Surge capability (L-N)

5 kV

Nominal output power

105 W

Maximum output power

105 W

Efficiency in full-load

92 %

at 230 V, 50 Hz

Nominal output current

500…1050 mA

Default output current

700 mA

Output current tolerance

±5 %

Output ripple current (100 Hz)

10 %

Output PSTLM

≤1

Output SVM

≤0.4

Minimum output current

100 mA

Galvanic isolation

double/reinforced

U-OUT (working voltage)

170 V

Nominal output voltage

75…150 V

Dimensions & weight

Length

153.6 mm

Width

68.0 mm

Height

37.0 mm

Mounting hole spacing, length

142.6 mm

Mounting hole spacing, width

34.0 mm

Product weight

700.00 g

Cable cross-section, input side

1.0 mm²

Cable cross-section, output side

1.0 mm²

Wire preparation length, input side

10 mm

Cable/wire length, control input

350 mm

Cable/wire length, input side

300 mm

Cable/wire length, output side

300 mm

Temperatures & operating conditions

Ambient temperature range

-40…+60 °C

Input voltage 200 – 277V, for Input voltage < 200V max. ta = 50°C

Temperature range at storage

-40…+80 °C

Maximum temperature at tc test point

85 °C

Max.housing temperature in case of fault

110 °C

Permitted rel. humidity during operation

5…85 %

Maximum 56 days/year at 85 %

Lifespan

ECG lifetime

50000 / 100000 h

At maximum Tc = 85°C / 10% failure rate / At maximum Tc = 75°C / 10% failure rate

Capabilities

Dimmable

Yes

Dimming interface

2DIM / 1…10 V / AstroDIM

Dimming range

10…100 %

Suitable for fixtures with prot. class

I

Constant lumen function

Programmable

NTC input

No

Short-circuit protection

Automatic reversible

No-load proof

Yes

Intended for no-load operation

No

Max. cable length to lamp/LED module

2.0 m

Output wires must be routed as close as possible to each other

Number of channels

1

Programming

Programming device

OT PROGRAMMER/5

Tuner4TRONIC

No

Certificates & standards

Type of protection

IP67

Standards

Acc. to EN 61347-1/Acc. to EN 61347-2-13/Acc. to EN 55015/Acc. to EN 61547/Acc. to EN 61000-3-2/Acc. to EN 62384/Acc. to EN 62386/GB 19510.1/GB 19510.14/GB 17625.1/UL-8750/FCC part 15/SASO 2927:2019

Approval marks – approval

CCC / CE / ENEC / UL

Logistical data

Commodity code

85044083900

Environmental information


Information according Art. 33 of EU Regulation (EC) 1907/2006 (REACh)

Date of Declaration

28-04-2023

Primary Article Identifier

4062172158169

Candidate List Substance 1

Lead

CAS No. of substance 1

7439-92-1

Safe Use Instruction

The identification of the Candidate List substance is sufficient to allow safe use of the article.

Declaration No. in SCIP database

e78c1538-1fa5-4028-8b2c-ae0cf2a8796d

Packaging information

EAN

Unit

Piece

Dimension l x w x h

Weight

Volume

4062172158169 UNV

Unpacked

1
4062172158176 VS

Shipping box

10 500mm x 310mm x 160mm 8110.00g 24.80dm³

Downloads

Accessories optional

Information about Family

Product family features
  • Available with different wattage: 100 W, 150 W, 200 W, 320 W
  • Input voltage: 100…277 V
  • Flexible current setting with programming tool
  • AstroDIM for autonomous dimming
  • Constant Lumen Output (CLO)
Ecodesign regulation information:
Intended for use with LED modules.
The forward voltage of the LED light source shall be within the defined operating window of the control gear in all operating conditions including dimming if applicable.

Separate control gear and light sources must be disposed of at certified disposal companies in accordance with Directive 2012/19/EU (WEEE) in the EU and with Waste Electrical and Electronic Equipment (WEEE) Regulations 2013 in the UK. For this purpose, collection points for recycling centres and take-back systems (CRSO) are available from retailers or private disposal companies, which accept separate control gear and light sources free of charge. In this way, raw materials are conserved and materials are recycled.

Products

Sort by:
Product
Nominal output current
Length
Width
Height
Data sheet
OT 100 UNV 1A0 2DIM P7
500…1050 mA 153.6 mm 68.0 mm 37.0 mm
OT 150 UNV 1A0 2DIM P7
520…1050 mA 173.6 mm 68.0 mm 37.0 mm
OT 200 UNV 1A0 2DIM P7
520…1050 mA 193.6 mm 68.0 mm 39.0 mm
OT 320 UNV 1A1 2DIM P7
520…1100 mA 231.0 mm 98.0 mm 42.0 mm