OT FIT 380/220...400/1A4 D NFC HC L
- Global usage - CE & cURus approval
- Flexible and future-proof current setting via NFC (Near Field Communication)
- Lifetime: up to 100,000 h (temperature at Tc = 65 °C, max. 10 % failure rate)
- Higher quality of light thanks to < 1% output ripple current
- Very high efficiency (up to 97%)
- Protection against 4 kV burst and 2 kV surge voltage (L-N and L-N/PE)
- Linear and area lighting
- Greenhouse lighting
- Industry lighting
- Suitable for luminaires of protection class I
Technical Data
Electrical data
Nominal input voltage
220 240/277/400 V
Mains frequency
50/60 Hz
Input voltage AC
198 440 V
Current set
NFC
Power factor λ
> 0.99
Efficiency in full-load
97 %
Device power loss
20 W
Inrush current
≤ 11 / ≤ 19 A
Max. ECG no. on circuit breaker 10 A (B)
8
Max. ECG no. on circuit breaker 10 A (C)
-
Max. ECG no. on circuit breaker 16 A (B)
13
Max. ECG no. on circuit breaker 16 A (C)
12
Max. ECG no. on circuit breaker 25 A (B)
-
Surge capability (L/N-Ground)
2 kV
Surge capability (L-N)
2 kV
Nominal output voltage
150 550 V
Nominal output current
400...1400 mA
Default output current
400 mA
Output ripple current (100 Hz)
< 1 %
Output PSTLM
≤1
Output SVM
≤0.4
Nominal output power
140 380 W
Maximum output power
380 W
Galvanic isolation
Non isolated
U-OUT (working voltage)
< 250 V
Total harmonic distortion
< 10 %
Output current tolerance
±5 %
Dimensions & weight
Mounting hole spacing, length
380.0 mm
Product weight
645.00 g
Cable cross-section, input side
0.5 1.5 mm²
Cable cross-section, output side
0.5 1.5 mm²
Wire preparation length, input side
8.0 9.0 mm
Wire preparation length, output side
8.0 9.0 mm
Height
40.0 mm
Width
40.0 mm
Length
400.0 mm
Colors & materials
Casing material
Metal
Temperatures & operating conditions
Ambient temperature range
-25 +70 °C
Maximum temperature at tc test point
85 °C
Max.housing temperature in case of fault
110 °C
Temperature range at storage
-40 +85 °C
Permitted rel. humidity during operation
5 85 %
Lifespan
ECG lifetime
100000 / 50000 h
Capabilities
Dimmable
No
Overheating protection
Automatic reversible
Overload protection
Automatic reversible
Short-circuit protection
Automatic reversible
No-load proof
Yes
Intended for no-load operation
No
Max. cable length to lamp/LED module
2.0 m
Suitable for fixtures with prot. class
I
Number of channels
1
Programming
Box programming
Yes
Tuner4TRONIC Field App
Yes
Programming device
NFC Reader
Certificates & standards
Approval marks approval
CE / VDE-ENEC / VDE-EMC / EAC / CCC / BIS / cURus
Standards
Acc. to IEC 61347-1/Acc. to IEC 61347-2-13/Acc. to IEC 62384/Acc. to IEC 61000-3-2/Acc. to IEC 61000-3-3/Acc. to IEC 61547/Acc. to CISPR 15/UL-8750/Acc. to FCC 47 part 15 class A
Type of protection
IP20
Logistical data
Commodity code
850440839000
Environmental information
Information according Art. 33 of EU Regulation (EC) 1907/2006 (REACh)
Date of Declaration
14-04-2022
Primary Article Identifier
4062172063586 | 4062172151221
Candidate List Substance 1
Lead
CAS No. of substance 1
7439-92-1
Safe Use Instruction
The identification of the Candidate List substance is sufficient to allow safe use of the article.
Declaration No. in SCIP database
d1b1aa5b-a9e0-4884-89ec-8e16bed1d07f | a649112d-272b-4287-b282-37036fa323fc
Packaging information
EAN |
Unit |
Piece |
Dimension l x w x h |
Weight |
Volume |
---|---|---|---|---|---|
4062172063586 |
UNV
| 1 | |||
4062172063593 |
VS
| 10 | 423mm x 208mm x 100mm | 6639.00g | 8.80dm³ |
Downloads
Data sheets
Accessories optional
Information about Family
Multiple applications are possible due to the wide range of Vin 200-400V and the broad operating windows that go up to 1.4 A and 550 Vout. Additional Highlights are the high surge robustness of 4kV/4kV and the integrated Constant Lumen Output (CLO).
- Line frequency: 47.5 60 Hz
- Versatile scope of application due to output power range of up to 380 W
- Supply voltage: 220 240 V / 277 V / 400 V
- Available with output current range: up to 1,400 mA
- Non-isolated drivers
Intended for use with LED modules.
The forward voltage of the LED light source shall be within the defined operating window of the control gear in all operating conditions including dimming if applicable.
Separate control gear and light sources must be disposed of at certified disposal companies in accordance with Directive 2012/19/EU (WEEE) in the EU and with Waste Electrical and Electronic Equipment (WEEE) Regulations 2013 in the UK. For this purpose, collection points for recycling centres and take-back systems (CRSO) are available from retailers or private disposal companies, which accept separate control gear and light sources free of charge. In this way, raw materials are conserved and materials are recycled.
Products
Product |
|
|
|
|
|
Data sheet | ||
---|---|---|---|---|---|---|---|---|
![]() |
OT FIT 380/220...400/1A4 D NFC HC L
|
150 550 V | 400...1400 mA | 400.0 mm | 40.0 mm | 40.0 mm |