OT FIT 150/220 240/1A0 D NFC IND L
- Flexible and future-proof current setting via NFC and LT2
- Lifetime: up to 100,000 h (temperature at Tc = 75 °C, max. 10 % failure rate)
- Wide operating temperature range: -40 +65 °C
- High quality of light thanks to <1% output ripple current
- High surge protection: up to 4 kV (L-N) / 4 kV (L/N-PE)
- Very high efficiency (up to 96%)
- Integrated inrush current limiter
- Fulfill safety requirement due to overload, overtemperature, Hot Plug protection
- Linear lighting solutions for industry, storage areas and retail applications
- Installation in emergency lighting systems according to IEC 61347-2-13, appendix J
- Suitable for installation in emergency lighting systems according to EN 60598-2-22
- Suitable for luminaires of protection class I
Technical Data
Electrical data
Nominal input voltage
220 240 V
Mains frequency
0/50/60 Hz
Input voltage AC
198 264 V
Input voltage DC
176 276 V
Current set
LEDset / NFC
Power factor λ
0.85C 0.99
Efficiency in full-load
95.5 %
Device power loss
11 W
Inrush current
5 A
Max. ECG no. on circuit breaker 10 A (B)
14
Max. ECG no. on circuit breaker 10 A (C)
-
Max. ECG no. on circuit breaker 16 A (B)
22
Max. ECG no. on circuit breaker 16 A (C)
-
Max. ECG no. on circuit breaker 25 A (B)
-
Surge capability (L/N-Ground)
4 kV
Surge capability (L-N)
4 kV
Nominal output voltage
64 300 V
Nominal output current
250 1000 mA
Default output current
125 mA
Output ripple current (100 Hz)
< 1 %
Output PSTLM
≤1
Output SVM
≤0.4
Nominal output power
43 150 W
Maximum output power
150 W
Galvanic isolation
Non isolated
Output current LEDset shorted
250 mA
Output current LEDset open
125 mA
Output current tolerance
±3 %
Total harmonic distortion
7 %
U-OUT (working voltage)
< 340 V
Dimensions & weight
Mounting hole spacing, length
350.0 mm
Product weight
260.00 g
Cable cross-section, input side
0.5 1.5 mm²
Cable cross-section, output side
0.5 1.5 mm²
Wire preparation length, input side
8.0 9.0 mm
Wire preparation length, output side
8.0 9.0 mm
Length
360.0 mm
Height
21.0 mm
Width
30.0 mm
Colors & materials
Casing material
Metal
Temperatures & operating conditions
Ambient temperature range
-40 +70 °C
Maximum temperature at tc test point
85 °C
Max.housing temperature in case of fault
110 °C
Temperature range at storage
-40 +85 °C
Permitted rel. humidity during operation
5 85 %
Lifespan
ECG lifetime
50000 / 100000 h
Additional product data
Encapsulated
No
Capabilities
Dimmable
No
Overheating protection
Automatic reversible
Overload protection
Automatic reversible
Short-circuit protection
Automatic reversible
No-load proof
Yes
Intended for no-load operation
No
Max. cable length to lamp/LED module
5.0 m
Suitable for fixtures with prot. class
I
Constant lumen function
Programmable
Suitable for emergency lighting
Yes
Number of channels
1
Programming
Tuner4TRONIC Field App
Yes
Box programming
Yes
Tuner4TRONIC
Yes
Programming device
NFC / LEDset
Certificates & standards
Approval marks approval
CE / EL / VDE-ENEC / EAC / CCC / BIS / RCM
Standards
Acc. to EN 61347-1/Acc. to EN 61347-2-13/Acc. to EN 62384/Acc. to EN 61000-3-2/Acc. to EN 61000-3-3/Acc. to EN 61547
Type of protection
IP20
Logistical data
Commodity code
850440839000
Environmental information
Information according Art. 33 of EU Regulation (EC) 1907/2006 (REACh)
Date of Declaration
28-04-2023
Primary Article Identifier
4052899990142
Candidate List Substance 1
Lead
CAS No. of substance 1
7439-92-1
Safe Use Instruction
The identification of the Candidate List substance is sufficient to allow safe use of the article.
Declaration No. in SCIP database
c1eeaa88-ec2e-4643-8df9-451d68f91219
Packaging information
EAN |
Unit |
Piece |
Dimension l x w x h |
Weight |
Volume |
---|---|---|---|---|---|
4052899990142 |
UNV
| 1 | 360mm x 30mm x 21mm | 260.00g | 0.23dm³ |
4052899990159 |
VS
| 20 | 385mm x 160mm x 100mm | 5375.00g | 6.16dm³ |
Downloads
Data sheets
Accessories optional
Information about Family
An integrated CLO contributes to maximizing the energy efficiency and very low LF and HF ripple help avoiding machine disturbances. CLO and currents are programmable by NFC and LT2 and the device also features an integrated inrush current limiter.
- Line frequency: 0 Hz | 50 Hz | 60 Hz
- Versatile scope of application due to output power range of up to 300 W
- Supply voltage: 220 240 V
- Available with output current range: up to 1,600 mA
- Constant Lumen Output (CLO)
- Non-isolated drivers
Intended for use with LED modules.
The forward voltage of the LED light source shall be within the defined operating window of the control gear in all operating conditions including dimming if applicable.
Separate control gear and light sources must be disposed of at certified disposal companies in accordance with Directive 2012/19/EU (WEEE) in the EU and with Waste Electrical and Electronic Equipment (WEEE) Regulations 2013 in the UK. For this purpose, collection points for recycling centres and take-back systems (CRSO) are available from retailers or private disposal companies, which accept separate control gear and light sources free of charge. In this way, raw materials are conserved and materials are recycled.
Products
Product |
|
|
|
|
|
Data sheet | ||
---|---|---|---|---|---|---|---|---|
![]() |
OT FIT 150/220
240/1A0 D NFC IND L
|
64 300 V | 250 1000 mA | 360.0 mm | 30.0 mm | 21.0 mm | ||
![]() |
OT FIT 300/220...240/1A6 D NFC IND L
|
60 300 V | 250...1550 mA | 360.0 mm | 46.0 mm | 28.0 mm |