OT FIT 15/220-240/350 NFC
- Fast programming / current set via NFC*
- High quality of light thanks to low output ripple current
- Small housing for flexible luminaire designs
- High efficiency
- Spot light and down light
- Offices
- Shops
- Hospitality
Technical Data
Electrical data
Nominal input voltage
220 240 V
Mains frequency
50/60 Hz
Input voltage AC
198 264 V
Total harmonic distortion
< 10 %
Power factor λ
0.65C...0.98
Efficiency in full-load
85 %
Device power loss
2.5 W
Inrush current
20 A
Max. ECG no. on circuit breaker 10 A (C)
-
Max. ECG no. on circuit breaker 10 A (B)
40
Max. ECG no. on circuit breaker 16 A (C)
-
Max. ECG no. on circuit breaker 16 A (B)
60
Max. ECG no. on circuit breaker 25 A (B)
-
Surge capability (L/N-Ground)
2 kV
Surge capability (L-N)
1 kV
Nominal output voltage
18 40 V
U-OUT (working voltage)
60 V
Nominal output current
150 350 mA
Output current tolerance
±7.5 %
Default output current
150 mA
Output ripple current (100 Hz)
< 5 %
Output PSTLM
≤1
Output SVM
≤0.4
Nominal output power
2.7 14 W
Maximum output power
14 W
Galvanic isolation primary/secondary
SELV
Current set
NFC
Galvanic isolation
SELV
Dimensions & weight
Mounting hole spacing, length
88.0 mm
Mounting hole spacing, width
34.0 mm
Product weight
80.00 g
Cable cross-section, input side
0.5 1.5 / 0.75 1.5 mm²
Cable cross-section, output side
0.5 1.5 / 0.75 1.5 mm²
Wire preparation length, input side
7 8 mm
Wire preparation length, output side
7 8 mm
Width
43.0 mm
Length
97.0 mm
Height
29.5 mm
Colors & materials
Casing material
Plastic
Temperatures & operating conditions
Ambient temperature range
-20 +50 °C
Maximum temperature at tc test point
70 °C
Max.housing temperature in case of fault
110 °C
Temperature range at storage
-25 85 °C
Permitted rel. humidity during operation
5 85 %
Lifespan
ECG lifetime
50000 / 100000 h
Additional product data
Predecessor EAN
4052899956995
Capabilities
Dimmable
No
Overheating protection
Automatic reversible
Overload protection
Yes
Short-circuit protection
Yes
No-load proof
Yes
Intended for no-load operation
No
Max. cable length to lamp/LED module
2.0 m
Suitable for fixtures with prot. class
I / II
Type of connection, input side
Push terminal
Type of connection, output side
Push terminal
Number of channels
1
Suitable for through-wiring
No
Programming
Programming device
NFC
Box programming
Yes
Tuner4TRONIC
Yes
Tuner4TRONIC Field App
Yes
Certificates & standards
Approval marks approval
CCC / CE / ENEC
Standards
Acc. to IEC 61347-1/Acc. to IEC 61347-2-13/Acc. to IEC 62384/Acc. to IEC 61000-3-2/Acc. to IEC 61000-3-3/Acc. to IEC 61547/Acc. to EN 55015, CISPR 15/Acc. to EN 62386
Type of protection
IP20
Protection class
II
Logistical data
Commodity code
85044083900
Environmental information
Information according Art. 33 of EU Regulation (EC) 1907/2006 (REACh)
Date of Declaration
16-08-2023
Primary Article Identifier
4052899617179
Candidate List Substance 1
Lead
CAS No. of substance 1
7439-92-1
Safe Use Instruction
The identification of the Candidate List substance is sufficient to allow safe use of the article.
Declaration No. in SCIP database
cf82b489-d43f-4437-b36a-5eb6274a589c
Packaging information
EAN |
Unit |
Piece |
Dimension l x w x h |
Weight |
Volume |
---|---|---|---|---|---|
4052899617179 |
UNV
| 1 | 97mm x 43mm x 29mm | 80.00g | 0.12dm³ |
4052899617636 |
VS
| 20 | 208mm x 158mm x 107mm | 1715.00g | 3.52dm³ |
Downloads
Data sheets
Accessories optional
Information about Family
- Output current range 150-1050 mA
- NFC Interface
- Low LF-ripple < 5%
- Lifetime: up to 50,000 h (temperature at max. tc )
Intended for use with LED modules.
The forward voltage of the LED light source shall be within the defined operating window of the control gear in all operating conditions including dimming if applicable.
Separate control gear and light sources must be disposed of at certified disposal companies in accordance with Directive 2012/19/EU (WEEE) in the EU and with Waste Electrical and Electronic Equipment (WEEE) Regulations 2013 in the UK. For this purpose, collection points for recycling centres and take-back systems (CRSO) are available from retailers or private disposal companies, which accept separate control gear and light sources free of charge. In this way, raw materials are conserved and materials are recycled.
Products
Product |
|
|
|
|
|
Data sheet | ||
---|---|---|---|---|---|---|---|---|
![]() |
OT FIT 15/220-240/350 NFC
|
18 40 V | 150 350 mA | 97.0 mm | 43.0 mm | 29.5 mm | ||
![]() |
OT FIT 25/220-240/700 NFC
|
18 40 V | 350 700 mA | 97.0 mm | 43.0 mm | 29.5 mm | ||
![]() |
OT FIT 40/220-240/1A0 NFC
|
18 40 V | 700...1050 mA | 97.0 mm | 43.0 mm | 29.5 mm |