OTi DALI 100/220 240/700 D NFC IND L
- Fully programmable via T4T software (NFC, DALI Interface)
- Lifetime: up to 100,000 h (temperature at Tc = 75 °C, max. 10 % failure rate)
- High light quality: 1 100% amplitude dimming and <1% output ripple current
- Wide operating temperature range: -40 +65 °C
- High surge protection: up to 4 kV (L-N) / 4 kV (L/N-PE)
- Integrated inrush current limiter
- Very high efficiency (up to 96%)
- Fulfill safety requirement due to overload, overtemperature, Hot Plug protection
- Easy to use in corridors and restrooms because of three-level Corridor function
- Touch DIM application: easy to control via pushbutton or sensor
- Energy efficient Touch DIM operation due to automatic switch-off at sufficient residual light
- Suitable for emergency Installations (acc. to EN 60598-2-22 and IEC 61347-2-13, appendix J) thanks to DC detection (0 Hz, pulsating DC), on/off switchable
- Feedback of power consumption and operating hours (Fit for SMART GRID)
- Suitable for buildings according to EPBD/BREEAM/LEED due to automatic Constant Lumen Output setting
- Luminaire information for easy maintenance
- Advanced luminaire/driver data (power, energy, operating hours ) for analytics
- Linear lighting solutions for industry, storage areas and retail applications
- Installation in emergency lighting systems according to IEC 61347-2-13, appendix J
- Suitable for installation in emergency lighting systems according to EN 60598-2-22
- Suitable for luminaires of protection class I
Technical Data
Electrical data
Nominal input voltage
220 240 V
Mains frequency
0/50/60 Hz
Input voltage AC
198 264 V
Input voltage DC
176 276 V
Current set
DALI / NFC / LEDset / Programmable
Total harmonic distortion
< 8 %
Power factor λ
> 0.98
Efficiency in full-load
94 %
Device power loss
9.0 W
Inrush current
5 A
Max. ECG no. on circuit breaker 10 A (C)
-
Max. ECG no. on circuit breaker 10 A (B)
23
Max. ECG no. on circuit breaker 16 A (B)
36
Max. ECG no. on circuit breaker 16 A (C)
-
Surge capability (L/N-Ground)
4 kV
Surge capability (L-N)
4 kV
Nominal output voltage
64 300 V
U-OUT (working voltage)
< 310 V
Nominal output current
200 700 mA
Output current LEDset open
100 mA
Output current LEDset shorted
200 mA
Default output current
100 mA
Output current tolerance
±3 %
Output ripple current (100 Hz)
< 1 %
Output PSTLM
≤1
Output SVM
≤0.4
Nominal output power
28 100 W
Maximum output power
100 W
Galvanic isolation
Non isolated
Power loss in stand-by mode
<0.2 W
Dimensions & weight
Mounting hole spacing, length
350.0 mm
Product weight
260.00 g
Cable cross-section, input side
0.5 1.5 mm²
Cable cross-section, output side
0.5 1.5 mm²
Wire preparation length, input side
8.0 9.0 mm
Wire preparation length, output side
8.0 9.0 mm
Length
360.0 mm
Height
21.0 mm
Width
30.0 mm
Colors & materials
Casing material
Metal
Temperatures & operating conditions
Ambient temperature range
-40 +65 °C
Maximum temperature at tc test point
85 °C
Max.housing temperature in case of fault
110 °C
Temperature range at storage
-40 +85 °C
Permitted rel. humidity during operation
5 85 %
Lifespan
ECG lifetime
50000 / 100000 h
Additional product data
Encapsulated
No
Capabilities
Programming interface
DALI, NFC, LEDset
Dimmable
Yes
Dimming interface
DALI-2 / Touch DIM / Touch DIM Sensor
Dimming range
1 100 %
Dimming method
Full analogue dimming
Constant lumen function
Programmable
Overheating protection
Automatic reversible
Overload protection
Non-reversible
Short-circuit protection
Automatic reversible
No-load proof
Yes
Intended for no-load operation
No
Max. cable length to lamp/LED module
5.0 m
Suitable for fixtures with prot. class
I
Suitable for emergency lighting
Yes
Type of connection, input side
Push terminal
Type of connection, output side
Push terminal
Control interface
DALI
Number of channels
1
DALI-2 Energy Data
Yes
DALI-2 Diagnostic Data
Yes
Programming
Programming device
DALI magic / NFC Scanner
Tuner4TRONIC
Yes
Tuner4TRONIC Field App
Yes
Box programming
Yes
Programmable features
Operating Current
Yes
Constant Lumen
Yes
Lamp Operating Time
Yes
Driver Guard
Yes
DALI Settings
Yes
Emergency Mode
Yes
DALI-2 Luminaire Data
Yes
Soft Switch Off
Yes
Dim to Dark
Yes
TouchDIM + Sensor
Yes
Corridor Functionality
Yes
Certificates & standards
Approval marks approval
CE / EL / VDE-ENEC / EAC / CCC / RCM / BIS
Standards
Acc. to EN 61347-1/Acc. to EN 61347-2-13/Acc. to EN 55015/Acc. to EN 61547/Acc. to EN 61000-3-2/Acc. to EN 62384/Acc. to EN 62386
Type of protection
IP20
Logistical data
Commodity code
850440839000
Environmental information
Information according Art. 33 of EU Regulation (EC) 1907/2006 (REACh)
Date of Declaration
18-10-2022
Primary Article Identifier
4052899559516
Candidate List Substance 1
Lead
CAS No. of substance 1
7439-92-1
Safe Use Instruction
The identification of the Candidate List substance is sufficient to allow safe use of the article.
Declaration No. in SCIP database
1a2a2563-fa7e-405d-8d4a-1f291bbf4f04
Packaging information
EAN |
Unit |
Piece |
Dimension l x w x h |
Weight |
Volume |
---|---|---|---|---|---|
4052899559516 |
UNV
| 1 | 360mm x 30mm x 21mm | 260.00g | 0.23dm³ |
4052899559523 |
VS
| 20 | 385mm x 160mm x 100mm | 5374.00g | 6.16dm³ |
Downloads
Data sheets
Accessories optional
Information about Family
For luminaire info and monitoring data the DiiA standards -251, -252 and -253 are integrated and the device also shows an integrated inrush current limiter. It is fully programmable by DALI, NFC and LT2 and a low LF and HF ripple help to avoid machine disturbances.
- Line frequency: 0 Hz | 50 Hz | 60 Hz
- Versatile scope of application thanks to an output power range of up to 300 W
- Supply voltage: 220 240 V
- Available with output current range: up to 1,000 mA
- Constant Lumen Output (CLO)
- Integrated customizable thermal management (Driver Guard)
- Non-isolated drivers
- DALI-2 certified (Part -101,-102 and -207)
Intended for use with LED modules.
The forward voltage of the LED light source shall be within the defined operating window of the control gear in all operating conditions including dimming if applicable.
Separate control gear and light sources must be disposed of at certified disposal companies in accordance with Directive 2012/19/EU (WEEE) in the EU and with Waste Electrical and Electronic Equipment (WEEE) Regulations 2013 in the UK. For this purpose, collection points for recycling centres and take-back systems (CRSO) are available from retailers or private disposal companies, which accept separate control gear and light sources free of charge. In this way, raw materials are conserved and materials are recycled.
Products
Product |
|
|
|
|
|
Data sheet | ||
---|---|---|---|---|---|---|---|---|
![]() |
OTi DALI 100/220
240/700 D NFC IND L
|
64 300 V | 200 700 mA | 360.0 mm | 30.0 mm | 21.0 mm | ||
![]() |
OTi DALI 300/220...240/1A6 D NFC IND L
|
60 300 V | 250...1550 mA | 360.0 mm | 45.0 mm | 28.0 mm |