OT FIT 7/220...240/180 CS PC
- Compatible with the most common leading-edge and trailing-edge phase dimmers
- Flexible current setting (DIPswitch 2 to 4 currents)
- Flicker-free dimming
- Higher quality of light thanks to < 5% output ripple current
- Decorative illumination
- Downlights, flat luminaires
- Hospitality
- Living areas
- Museums, residential buildings
- Offices
- Shop lighting
- Suitable for indoor SELV installations
- Suitable for luminaires of protection class I and II
Technical Data
Electrical data
Nominal input voltage
220 240 V
Mains frequency
50/60 Hz
Input voltage AC
198 264 V
Total harmonic distortion
< 20 %
Power factor λ
0.95
Efficiency in full-load
> 79 %
Device power loss
1.8 W
Protective conductor current
<0.7 mA
Inrush current
< 10 A
Max. ECG no. on circuit breaker 10 A (C)
132
Max. ECG no. on circuit breaker 10 A (B)
80
Max. ECG no. on circuit breaker 16 A (C)
212
Max. ECG no. on circuit breaker 16 A (B)
128
Surge capability (L/N-Ground)
2 kV
Surge capability (L-N)
1 kV
Nominal output voltage
27 40 V
U-OUT (working voltage)
60 V
Nominal output current
100 / 120 / 155 / 180 mA
Output current tolerance
±7.5 %
Output ripple current (100 Hz)
< 5 %
Output PSTLM
≤1
Output SVM
≤0.4
Nominal output power
2.7 7.2 W
Maximum output power
7.2 W
Default output current
180 mA
Galvanic isolation primary/secondary
SELV
Current set
DipSwitch
Dimensions & weight
Product weight
60.00 g
Cable cross-section, input side
0.5 1.5 mm²
Cable cross-section, output side
0.75 1.5 mm²
Wire preparation length, input side
8.0 9.0 mm
Wire preparation length, output side
8.0 9.0 mm
Height
22.2 mm
Length
130.0 mm
Width
30.0 mm
Colors & materials
Casing material
80% recycled plastic
Temperatures & operating conditions
Ambient temperature range
-20 +50 °C
Maximum temperature at tc test point
70 °C
Max.housing temperature in case of fault
110 °C
Temperature range at storage
-20 80 °C
Permitted rel. humidity during operation
5 85 %
Lifespan
ECG lifetime
50000 h
Capabilities
Dimmable
Yes
Dimming interface
Phase Cut
Dimming range
5 100 %
Dimming method
Amplitude Modulation
Overheating protection
Automatic reversible
Overload protection
Automatic reversible
Short-circuit protection
Automatic reversible
No-load proof
Yes
Intended for no-load operation
No
Max. cable length to lamp/LED module
2.0 m
Suitable for fixtures with prot. class
I / II
Type of connection, input side
Push terminal
Type of connection, output side
Push terminal
Suitable for through-wiring
No
Number of channels
1
Programming
Programming device
DIPswitch
Certificates & standards
Approval marks approval
CCC / CE / UKCA / ENEC
Standards
Acc. to IEC 61347-1/Acc. to IEC 61347-2-3/Acc. to IEC 62384/Acc. to IEC 61547/Acc. to IEC 61000-3-3/Acc. to EN 61000-3-2
Protection class
I,II
Type of protection
IP20
Logistical data
Commodity code
850440839000
Environmental information
Information according Art. 33 of EU Regulation (EC) 1907/2006 (REACh)
Date of Declaration
25-05-2023
Primary Article Identifier
4062172286541
Candidate List Substance 1
Lead
CAS No. of substance 1
7439-92-1
Safe Use Instruction
The identification of the Candidate List substance is sufficient to allow safe use of the article.
Declaration No. in SCIP database
73cb25ed-8d1b-4460-9a34-648ebf6a2c3c
Packaging information
EAN |
Unit |
Piece |
Dimension l x w x h |
Weight |
Volume |
---|---|---|---|---|---|
4062172286541 |
UNV
| 1 | 130mm x 30mm x 22mm | 60.00g | 0.09dm³ |
4062172286558 |
VS
| 20 | 396mm x 162mm x 67mm | 1365.00g | 4.30dm³ |
Downloads
Data sheets
Information about Family
The compatibility with the most common leading-edge and trailing-edge phase dimmers and the possibility of dimming from 5-100% marks one of the key characteristics. Others include a cable clamp for independent installations and DIP switsches for 4 output currents per wattage.
- Cable clamp housing for independent mounting
- Dimmable on the leading edge and trailing edge
- Housing for independent installation
Intended for use with LED modules.
The forward voltage of the LED light source shall be within the defined operating window of the control gear in all operating conditions including dimming if applicable.
Separate control gear and light sources must be disposed of at certified disposal companies in accordance with Directive 2012/19/EU (WEEE) in the EU and with Waste Electrical and Electronic Equipment (WEEE) Regulations 2013 in the UK. For this purpose, collection points for recycling centres and take-back systems (CRSO) are available from retailers or private disposal companies, which accept separate control gear and light sources free of charge. In this way, raw materials are conserved and materials are recycled.
Products
Product |
|
|
|
|
|
Data sheet | ||
---|---|---|---|---|---|---|---|---|
![]() |
OT FIT 7/220...240/180 CS PC
|
27 40 V | 100 / 120 / 155 / 180 mA | 130.0 mm | 30.0 mm | 22.2 mm | ||
![]() |
OT FIT 8/220...240/180 CS PC
|
27 40 V | 100 / 120 / 155 / 180 mA | 95.0 mm | 50.0 mm | 22.0 mm | ||
![]() |
OT FIT 8/220...240/180 CS PC SC
|
27 40 V | 100 / 120 / 155 / 180 mA | 95.0 mm | 50.0 mm | 22.0 mm | ||
![]() |
OT FIT 14/220...240/350 CS PC
|
27 40 V | 200 / 250 / 300 / 350 mA | 130.0 mm | 30.0 mm | 22.2 mm | ||
![]() |
OT FIT 18/220...240/450 CS PC
|
27 40 V | 225 / 325 / 350 / 450 mA | 95.0 mm | 50.0 mm | 22.0 mm | ||
![]() |
OT FIT 18/220...240/450 CS PC SC
|
27 40 V | 225 / 325 / 350 / 450 mA | 95.0 mm | 50.0 mm | 22.0 mm | ||
![]() |
OT FIT 30/220
240/700 CS PC
|
27 40 V | 500 / 700 mA | 95.0 mm | 53.0 mm | 30.0 mm | ||
![]() |
OT FIT 40/220...240/1A0 CS PC
|
27 40 V | 800 / 900 / 950 / 1050 mA | 108.0 mm | 67.0 mm | 22.0 mm | ||
![]() |
OT FIT 40/220...240/1A0 CS PC SC
|