DULUX F 24 W/840 2G10
- Suitable for operation on electronic and conventional control gear
References / Links
For more information on QUICKTRONIC electronic control gear go to www.osram.com/QUICKTRONIC
Technical Data
Electrical data
Nominal current
0.34 A A
Photometrical data
Light color (designation)
LUMILUX Cool White
Rated LLMF at 4,000 h
0.86
Rated LLMF at 6,000 h
0.83
Rated LLMF at 8,000 h
0.81
Rated LLMF at 12,000 h
0.77
Luminous flux
1700 lm
Color rendering index Ra
≥80
Dimensions & weight
Overall length
170.00 mm
Tube diameter
17,5 mm
Length with base excl. base pins/connection
162 mm
Product weight
85.84 g
Temperatures & operating conditions
Ambient temperature range
-5 +40 °C
Lifespan
Service life
9000 h
Nominal lamp life time
13000 h
Additional product data
Mercury content
2.5 mg
Appropriate disposal acc. to WEEE
Yes
Certificates & standards
Energy efficiency class
G
Energy consumption
26.00 kWh/1000h
Country specific categorizations
ILCOS
FSD-24/840-E-2G10-90/165
Environmental information
Information according Art. 33 of EU Regulation (EC) 1907/2006 (REACh)
Date of Declaration
18-04-2022
Primary Article Identifier
4050300333588
Declaration No. in SCIP database
In work
Packaging information
EAN |
Unit |
Piece |
Dimension l x w x h |
Weight |
Volume |
---|---|---|---|---|---|
4050300333588 |
FS
| 1 | |||
4050300333595 |
VS
| 10 | 280mm x 105mm x 195mm | 1319.00g | 5.73dm³ |
Downloads
Lamp-ECG Combination
QT-ECO 1x18-24/220-240 S
Nominal current
0.16 A
Nominal wattage + Power loss
22.50 W
Power factor λ [PIM]
0.60 c
Luminous flux at 35 °C
1500 lm
Number of lighting outlets
1
QTi 1x14/24 DIM
Nominal current
0.11 A
Nominal wattage + Power loss
25.00 W
Power factor λ [PIM]
0.98
Luminous flux at 35 °C
1700 lm
Ambient temperature range [PIM] REM
Operation at up to -20 °C for all QTi (DALI) DIM-ECG possible. Lowest dimming position must be limited. Details see technical dimming brochure.
Number of lighting outlets
1
QTi 2x14/24 DIM
Nominal current
0.22 A
Nominal wattage + Power loss
49.00 W
Power factor λ [PIM]
0.98
Luminous flux at 35 °C
1700 lm
Ambient temperature range [PIM] REM
Operation at up to -20 °C for all QTi (DALI) DIM-ECG possible. Lowest dimming position must be limited. Details see technical dimming brochure.
Number of lighting outlets
2
QTi 3x14/24 DIM
Nominal current
0.32 A
Nominal wattage + Power loss
74.00 W
Power factor λ [PIM]
0.99
Luminous flux at 35 °C
1700 lm
Ambient temperature range [PIM] REM
Operation at up to -20 °C for all QTi (DALI) DIM-ECG possible. Lowest dimming position must be limited. Details see technical dimming brochure.
Number of lighting outlets
3
QTi 4x14/24 DIM
Nominal current
0.43 A
Nominal wattage + Power loss
97.60 W
Power factor λ [PIM]
0.99
Luminous flux at 35 °C
1800 lm
Ambient temperature range [PIM] REM
Operation at up to -20 °C for all QTi (DALI) DIM-ECG possible. Lowest dimming position must be limited. Details see technical dimming brochure.
Number of lighting outlets
4
QTi DALI 1x14/24 DIM
Nominal current
0.11 A
Nominal wattage + Power loss
25.00 W
Power factor λ [PIM]
0.98
Luminous flux at 35 °C
1700 lm
Ambient temperature range [PIM] REM
Operation at up to -20 °C for all QTi (DALI) DIM-ECG possible. Lowest dimming position must be limited. Details see technical dimming brochure.
Number of lighting outlets
1
QTi DALI 2x14/24 DIM
Nominal current
0.22 A
Nominal wattage + Power loss
49.00 W
Power factor λ [PIM]
0.98
Luminous flux at 35 °C
1700 lm
Ambient temperature range [PIM] REM
Operation at up to -20 °C for all QTi (DALI) DIM-ECG possible. Lowest dimming position must be limited. Details see technical dimming brochure.
Number of lighting outlets
2
QTi DALI 3x14/24 DIM
Nominal current
0.32 A
Nominal wattage + Power loss
73.40 W
Power factor λ [PIM]
0.99
Luminous flux at 35 °C
1700 lm
Ambient temperature range [PIM] REM
Operation at up to -20 °C for all QTi (DALI) DIM-ECG possible. Lowest dimming position must be limited. Details see technical dimming brochure.
Number of lighting outlets
3
QT-M 2x26-42/220-240 S
Nominal current
0.23 A
Nominal wattage + Power loss
54.00 W
Power factor λ [PIM]
0.97
Luminous flux at 35 °C
1700 lm
Number of lighting outlets
2
QTP-M 1x26-42
Nominal current
0.12 A
Nominal wattage + Power loss
25.00 W
Power factor λ [PIM]
0.94 c
Luminous flux at 35 °C
1650 lm
Number of lighting outlets
1
QTP-M 2x26-32
Nominal current
0.21 A
Nominal wattage + Power loss
48.00 W
Power factor λ [PIM]
0.97
Luminous flux at 35 °C
1650 lm
Number of lighting outlets
2
QTP-OPTIMAL 1x18-40
Nominal current
0.12 A
Nominal wattage + Power loss
25.00 W
Power factor λ [PIM]
0.95
Luminous flux at 35 °C
1650 lm
Number of lighting outlets
1
QTP-OPTIMAL 2x18-40
Nominal current
0.23 A
Nominal wattage + Power loss
50.00 W
Power factor λ [PIM]
0.98
Luminous flux at 35 °C
1650 lm
Number of lighting outlets
2
ECG_1.1 Ambient temperature for lifespan
40 °C
ECG_1.2 Ambient temperature for lifespan
50 °C
ECG_1.3 Ambient temperature for lifespan
60 °C
ECG_2.1 Tc point temperature for lifespa
50 °C
ECG_2.2 Tc point temperature for lifespa
60 °C
ECG_2.3 Tc point temperature for lifespa
65 °C
ECG_3.1 Temperature dependent lifespan
100000 h
ECG_3.2 Temperature dependent lifespan
100000 h
ECG_3.3 Temperature dependent lifespan
90000 h
Information about Family
Separate control gear and light sources must be disposed of at certified disposal companies in accordance with Directive 2012/19/EU (WEEE) in the EU and with Waste Electrical and Electronic Equipment (WEEE) Regulations 2013 in the UK. For this purpose, collection points for recycling centres and take-back systems (CRSO) are available from retailers or private disposal companies, which accept separate control gear and light sources free of charge. In this way, raw materials are conserved and materials are recycled.
Products
Product |
|
Data sheet | ||
---|---|---|---|---|
![]() |
DULUX F 18 W/840 2G10
|
128.00 mm | ||
![]() |
DULUX F 24 W/830 2G10
|
170.00 mm | ||
![]() |
DULUX F 24 W/840 2G10
|
170.00 mm | ||
![]() |
DULUX F 36 W/830 106 V 2G10
|
221.00 mm | ||
![]() |
DULUX F 36 W/840 2G10
|
221.00 mm |