DULUX L 36 W/840 2G11
Equipment / Accessories
- Suitable for standard control gears and starters
- Suitable for operation on electronic and conventional control gear
References / Links
For more information on QUICKTRONIC electronic control gear go to www.osram.com/QUICKTRONIC
For more information on the system guarantee and the terms and conditions of the guarantee visit https://www.inventronics-light.com/multilevel-guarantees
Technical Data
Electrical data
Nominal current
0.43 A A
Photometrical data
Light color (designation)
LUMILUX Cool White
Rated LLMF at 4,000 h
0.9
Rated LLMF at 6,000 h
0.88
Rated LLMF at 8,000 h
0.85
Rated LLMF at 12,000 h
0.84
Rated LLMF at 16,000 h
0.81
Rated LLMF at 20,000 h
0.8
Luminous flux
2600 lm
Color rendering index Ra
≥80
Dimensions & weight
Overall length
415.00 mm
Tube diameter
17,5 mm
Length with base excl. base pins/connection
409 mm
Product weight
94.29 g
Temperatures & operating conditions
Ambient temperature range
-5 +40 °C
Lifespan
Service life
13000 h
Nominal lamp life time
20000 h
Additional product data
Mercury content
3.5 mg
Product remark
For ECG and CCG operation
Appropriate disposal acc. to WEEE
Yes
Certificates & standards
Energy efficiency class
G
Energy consumption
38.00 kWh/1000h
Country specific categorizations
ILCOS
FSD-36/840-E-2G11-43,9/411
Environmental information
Information according Art. 33 of EU Regulation (EC) 1907/2006 (REACh)
Date of Declaration
18-04-2022
Primary Article Identifier
4050300010786
Declaration No. in SCIP database
In work
Packaging information
EAN |
Unit |
Piece |
Dimension l x w x h |
Weight |
Volume |
---|---|---|---|---|---|
4050300010786 |
FS
| 1 | 46mm x 26mm x 442mm | 129.00g | 0.53dm³ |
4050300242224 |
VS
| 10 | 136mm x 103mm x 455mm | 1415.00g | 6.37dm³ |
Downloads
Lamp-ECG Combination
QTi 1x14/24/21/39 GII
Nominal current
0.15 A
Nominal wattage + Power loss
34.00 W
Power factor λ [PIM]
0.96
Luminous flux at 35 °C
2750 lm
Number of lighting outlets
1
QTi 2x14/24/21/39 GII
Nominal current
0.29 A
Nominal wattage + Power loss
68.00 W
Power factor λ [PIM]
0.98
Luminous flux at 35 °C
2800 lm
Number of lighting outlets
2
QT-M 2x26-42/220-240 S
Nominal current
0.30 A
Nominal wattage + Power loss
70.00 W
Power factor λ [PIM]
0.97
Luminous flux at 35 °C
2800 lm
Number of lighting outlets
2
QTP-DL 2x36-40
Nominal current
0.33 A
Nominal wattage + Power loss
68.00 W
Power factor λ [PIM]
0.99
Luminous flux at 35 °C
2900 lm
Number of lighting outlets
2
QTP-M 1x26-42
Nominal current
0.16 A
Nominal wattage + Power loss
35.00 W
Power factor λ [PIM]
0.97
Luminous flux at 35 °C
2800 lm
Number of lighting outlets
1
QTP-M 2x26-32
Nominal current
0.30 A
Nominal wattage + Power loss
68.00 W
Power factor λ [PIM]
0.97
Luminous flux at 35 °C
2800 lm
Number of lighting outlets
2
QTP-OPTIMAL 1x18-40
Nominal current
0.16 A
Nominal wattage + Power loss
35.00 W
Power factor λ [PIM]
0.98
Luminous flux at 35 °C
2800 lm
Number of lighting outlets
1
QTP-OPTIMAL 2x18-40
Nominal current
0.30 A
Nominal wattage + Power loss
70.00 W
Power factor λ [PIM]
0.98
Luminous flux at 35 °C
2800 lm
Number of lighting outlets
2
ECG_1.1 Ambient temperature for lifespan
40 °C
ECG_1.2 Ambient temperature for lifespan
50 °C
ECG_1.3 Ambient temperature for lifespan
60 °C
ECG_2.1 Tc point temperature for lifespa
55 °C
ECG_2.2 Tc point temperature for lifespa
60 °C
ECG_2.3 Tc point temperature for lifespa
70 °C
ECG_3.1 Temperature dependent lifespan
100000 h
ECG_3.2 Temperature dependent lifespan
100000 h
ECG_3.3 Temperature dependent lifespan
70000 h
Information about Family
Ecodesign regulation information:
Separate control gear and light sources must be disposed of at certified disposal companies in accordance with Directive 2012/19/EU (WEEE) in the EU and with Waste Electrical and Electronic Equipment (WEEE) Regulations 2013 in the UK. For this purpose, collection points for recycling centres and take-back systems (CRSO) are available from retailers or private disposal companies, which accept separate control gear and light sources free of charge. In this way, raw materials are conserved and materials are recycled.
Separate control gear and light sources must be disposed of at certified disposal companies in accordance with Directive 2012/19/EU (WEEE) in the EU and with Waste Electrical and Electronic Equipment (WEEE) Regulations 2013 in the UK. For this purpose, collection points for recycling centres and take-back systems (CRSO) are available from retailers or private disposal companies, which accept separate control gear and light sources free of charge. In this way, raw materials are conserved and materials are recycled.
Products
Product |
|
Data sheet | ||
---|---|---|---|---|
![]() |
DULUX L 18 W/830 2G11
|
221.00 mm | ||
![]() |
DULUX L 18 W/840 2G11
|
221.00 mm | ||
![]() |
DULUX L 24 W/840 2G11
|
321.00 mm | ||
![]() |
DULUX L 36 W/830 2G11
|
415.00 mm | ||
![]() |
DULUX L 36 W/840 2G11
|
415.00 mm | ||
![]() |
DULUX L 40 W/840 2G11
|
538.00 mm | ||
![]() |
DULUX L 55 W/830 2G11
|
538.00 mm | ||
![]() |
DULUX L 55 W/840 2G11
|
538.00 mm | ||
![]() |
DULUX L 55 W/865 2G11
|
538.00 mm | ||
![]() |
DULUX L 80 W/840 2G11
|
565.00 mm |