DULUX T/E PLUS 18 W/840

Equipment / Accessories
  • Suitable for operation on electronic control gear

References / Links
For more information on QUICKTRONIC electronic control gear go to www.osram.com/QUICKTRONIC

Technical Data

Electrical data

Nominal current

0.23 A A

Photometrical data

Light color (designation)

LUMILUX Cool White

Rated LLMF at 2,000 h

0.9

Rated LLMF at 4,000 h

0.84

Rated LLMF at 6,000 h

0.83

Rated LLMF at 8,000 h

0.81

Rated LLMF at 12,000 h

0.79

Rated LLMF at 16,000 h

0.78

Rated LLMF at 20,000 h

0.77

Color rendering index Ra

≥80

Luminous flux

1200 lm

Dimensions & weight

Overall length

117.00 mm

Length with base excl. base pins/connection

101,00 mm

Product weight

56.00 g

Temperatures & operating conditions

Ambient temperature range

-5…+40 °C

Lifespan

Service life

13000 h

Nominal lamp life time

20000 h

Additional product data

Mercury content

2.0 mg

Product remark

For ECG operation only

Appropriate disposal acc. to WEEE

Yes

Certificates & standards

Energy efficiency class

G

Energy consumption

19.00 kWh/1000h

Country specific categorizations

ILCOS

FSMH-18/840-/P/-GX24q-2

Environmental information


Information according Art. 33 of EU Regulation (EC) 1907/2006 (REACh)

Date of Declaration

18-04-2022

Primary Article Identifier

4050300342221

Declaration No. in SCIP database

In work

Packaging information

EAN

Unit

Piece

Dimension l x w x h

Weight

Volume

4050300342221 FS

Folding box

1 49mm x 46mm x 129mm 71.00g 0.29dm³
4050300342238 VS

Shipping box

10 256mm x 101mm x 142mm 783.00g 3.67dm³

Downloads

Lamp-ECG Combination
QTP-T/E (1X18), 2X18

Nominal current

0.16 A

Nominal wattage + Power loss

36.00 W

Power factor λ [PIM]

0.98

Luminous flux at 25 °C

2*2200 lm

Number of lighting outlets

2

ECG_1.1 Ambient temperature for lifespan

40 °C

ECG_1.2 Ambient temperature for lifespan

50 °C

ECG_1.3 Ambient temperature for lifespan

60 °C

ECG_2.1 Tc point temperature for lifespa

55 °C

ECG_2.2 Tc point temperature for lifespa

65 °C

ECG_2.3 Tc point temperature for lifespa

70 °C

ECG_3.1 Temperature dependent lifespan

100000 h

ECG_3.2 Temperature dependent lifespan

100000 h

ECG_3.3 Temperature dependent lifespan

60000 h

QTP-T/E 1X18, (2X18)

Nominal current

0.09 A

Nominal wattage + Power loss

19.00 W

Power factor λ [PIM]

0.90 c

Luminous flux at 25 °C

1*1200 lm

Number of lighting outlets

1

Information about Family

Ecodesign regulation information:
Separate control gear and light sources must be disposed of at certified disposal companies in accordance with Directive 2012/19/EU (WEEE) in the EU and with Waste Electrical and Electronic Equipment (WEEE) Regulations 2013 in the UK. For this purpose, collection points for recycling centres and take-back systems (CRSO) are available from retailers or private disposal companies, which accept separate control gear and light sources free of charge. In this way, raw materials are conserved and materials are recycled.