PTi 35/220 240 S
- Long reliable life at maximum permitted temperatures
- Compact dimensions and low weight for small luminaire designs
- Excellent thermal behavior for very high limit temperatures tc and ta
- Automatic safety shutdown of lamps in the event of a defect or at end of life (EoL)
- Shop lighting
- Health and fitness areas (in luminaires with protection class IP66 or higher)
- Effect and accent lighting
Safety advice
Ballast losses and lamp heat radiation can lead to heat accumulation in a completely closed case. Therefore it is necessary to ensure that the temperature at the measuring point t of the ECG does not exceed the maximum value.
Attention!
For safety reasons disconnect the device before replacing the lamp!
Any conductive material must have a minimum distance of 4 mm to the front of the terminal block.
Installation by qualified electrician only.
Terminals for protective earth not suitable for any through connection.
Technical Data
Electrical data
Lamp wattage
39 W
Maximum output power
39 W
Line current
0.19 A
Ignition voltage
4.5 kVp
Operating frequency
0.200 0.240 kHz
System wattage
43.00 W
Efficiency in full-load
91 %
Input voltage AC
198 264 V
Nominal voltage
220 240 V
Mains frequency
50 60 Hz
Power factor λ
0.95
Inrush current
30 A
Max. ECG no. on circuit breaker 10 A (B)
15
Max. ECG no. on circuit breaker 16 A (B)
26
Max. no. of ECGs on 16A MCB with EBN-OS
65
Protective conductor current
0.25 mA
U-OUT (working voltage)
250 V
Max. working voltage between LH and LL
250 V
Max. working voltage betw. LL/LH & earth
250 V
Max. capacitance of wire ECG/lamp
120 pF
Dimensions & weight
Length
110.0 mm
Width
75.0 mm
Height
30.0 mm
Mounting hole spacing, length
99.0 mm
Mounting hole spacing, width
64.0 mm
Cable cross-section, input side
0.5 2.5 mm²
Cable cross-section, output side
0.5 2.5 mm²
Wire preparation length, input side
10 11 mm
Wire preparation length, output side
10 11 mm
Product weight
250.00 g
Colors & materials
Casing material
Metal
Temperatures & operating conditions
Ambient temperature range
-25 +65 °C
Maximum temperature at tc test point
85 °C
Lifespan
ECG lifetime
50000 h
Additional product data
Design / version
Built-in unit
Suitable for lamp power (1 lamp)
39 W
Capabilities
Max. cable length to lamp/LED module
1.5 m
Overheating protection
Power reduction and switch off at T > 85 °C at the tc point
Overvoltage protection at 275 300 V
48 h
Overvoltage protection at 300 320 V
2 h
Overvoltage protection at 320 350 V
5 min
ECG reset time
> 0.5 s
Dimmable
No
Restriction on ignition time
20 min
Suitable for fixtures with prot. class
I
Intended for no-load operation
No
Certificates & standards
Approval marks approval
ENEC 10 / VDE / VDE-EMC / EAC / C-Tick
Type of protection
IP20
EEI Energy Label
A2
Standards
Acc. to EN 61547/Acc. to EN 61000-3-2/IEC 1000-3-2/Acc. to EN 61347-2-12/Acc. to EN 55015/Acc. to EN 61000-3-2/Acc. to EN 61547
Logistical data
Commodity code
85041080900
Environmental information
Information according Art. 33 of EU Regulation (EC) 1907/2006 (REACh)
Date of Declaration
26-05-2023
Primary Article Identifier
4008321073112
Candidate List Substance 1
Lead
CAS No. of substance 1
7439-92-1
Safe Use Instruction
The identification of the Candidate List substance is sufficient to allow safe use of the article.
Declaration No. in SCIP database
08ba73c3-774a-44b6-ad92-2341e3613ca0
Packaging information
EAN |
Unit |
Piece |
Dimension l x w x h |
Weight |
Volume |
---|---|---|---|---|---|
4008321073112 |
UNV
| 1 | 110mm x 75mm x 30mm | 250.00g | 0.25dm³ |
4008321074522 |
VS
| 20 | 412mm x 136mm x 186mm | 5169.89g | 10.42dm³ |
Downloads
Data sheets
Information about Family
- Energy Efficiency Index EEI: A2
- Supply voltage: 220 240 V
- Line frequency: 50 60 Hz
- RI suppression: to EN 55015/CISPR 15
- Safety: to EN 61347-2-12
- Line harmonics according to EN 61000-3-2
- Immunity according to EN 61547
Separate control gear and light sources must be disposed of at certified disposal companies in accordance with Directive 2012/19/EU (WEEE) in the EU and with Waste Electrical and Electronic Equipment (WEEE) Regulations 2013 in the UK. For this purpose, collection points for recycling centres and take-back systems (CRSO) are available from retailers or private disposal companies, which accept separate control gear and light sources free of charge. In this way, raw materials are conserved and materials are recycled.
Products
Product |
|
|
|
|
|
Data sheet | ||
---|---|---|---|---|---|---|---|---|
![]() |
PTi 35/220
240 S
|
30.0 mm | 110.0 mm | 220 240 V | 39 W | 4.5 kVp | ||
![]() |
PTi 35/220
240 S MINI
|
30.0 mm | 97.0 mm | 220 240 V | 39 W | 3.0 kVp | ||
![]() |
PTi 70/220
240 S
|
30.0 mm | 110.0 mm | 220 240 V | 73 W | 4.5 kVp | ||
![]() |
PTi 150/220
240 S
|
31.0 mm | 150.0 mm | 220 240 V | 147 W | 4.5 kVp |