QT-FIT 5/8 2X18…39

Product family benefits
  • Long lamp life
  • No adverse effect from frequent on/off switching
  • Automatic restart after lamp replacement
  • Perfect lamp start for applications with motion sensors
  • VDE/VDE EMC certified system
  • Very high energy efficiency due to cut-off technology
Areas of application
  • Open-plan offices, corridors and storage rooms
  • Public buildings
  • Strip lighting
  • Suitable for luminaires of protection class I
  • Modernization of existing systems

Technical Data

Electrical data

Input voltage AC

198…264 V

Nominal voltage

220…240 V

Mains frequency

50…60 Hz

Input voltage DC

185…264 V

Minimum voltage for lamp ignition: 198 V, 185…198 V for maximum 1 h

Maximum output power

2 x 39 W

Efficiency in full-load

91 %

at 230 V, 50 Hz

Operating frequency

40…50 kHz

Max. ECG no. on circuit breaker 10 A (B)

12

Type B

Max. ECG no. on circuit breaker 16 A (B)

19

Type B

Inrush current

40 A

Light technical data

Starting time

2.0 s

Dimensions & weight

Length

280.0 mm

Width

30.0 mm

Height

21.0 mm

Mounting hole spacing, length

270.0 mm

Product weight

183.00 g

Cable cross-section, output side

0.5…1.5 mm²

Solid leads

Cable cross-section, input side

0.5…1.5 mm²

Solid leads

Temperatures & operating conditions

Ambient temperature range

-15…+50 °C

Permitted rel. humidity during operation

5…85 %

Maximum 56 days/year at 85 %

Lifespan

ECG lifetime

50000 h

Additional product data

Suitable for lamp power (2 lamps)

18…39 W

Capabilities

End of lamp life safety shutdown

EOL T.2

Suitable for fixtures with prot. class

I

Max. cable length to lamp/LED module

2.0 m / 1.0 m

Dimmable

No

Intended for no-load operation

No

Certificates & standards

Approval marks – approval

CE / VDE / ENEC 10 / VDE-EMC

EEI – Energy Label

A2

Standards

Acc. to EN 61347-2-3/IEC 61347-2-3/Acc. to EN 55015:2006 + A1:2007 + A2:2009/Acc. to EN 61000-3-2/IEC 61000-3-2/Acc. to EN 61547/IEC 61547

Protection class

I

Type of protection

IP20

Logistical data

Commodity code

85041080900

Environmental information


Information according Art. 33 of EU Regulation (EC) 1907/2006 (REACh)

Date of Declaration

19-05-2023

Primary Article Identifier

4008321873903

Candidate List Substance 1

Lead

CAS No. of substance 1

7439-92-1

Safe Use Instruction

The identification of the Candidate List substance is sufficient to allow safe use of the article.

Declaration No. in SCIP database

4a8400e1-1611-4742-af7d-6b2c52cf9144

Packaging information

EAN

Unit

Piece

Dimension l x w x h

Weight

Volume

4008321873903 UNV

Unpacked

1 280mm x 30mm x 21mm 183.00g 0.18dm³
4008321873910 VS

Shipping box

20 312mm x 165mm x 98mm 3801.00g 5.05dm³

Downloads

Lamp-ECG Combination
HO 24 W

Nominal current

0.24 A

Nominal wattage + Power loss

53.00 W

Power factor λ [PIM]

0.98

Luminous flux at 35 °C

1750 lm

Number of lighting outlets

2

ECG_1.1 Ambient temperature for lifespan

40 °C

ECG_1.2 Ambient temperature for lifespan

50 °C

ECG_1.3 Ambient temperature for lifespan

60 °C

ECG_2.1 Tc point temperature for lifespa

55 °C

ECG_2.2 Tc point temperature for lifespa

60 °C

ECG_2.3 Tc point temperature for lifespa

70 °C

ECG_3.1 Temperature dependent lifespan

100000 h

ECG_3.2 Temperature dependent lifespan

70000 h

ECG_3.3 Temperature dependent lifespan

40000 h

HO 39 W

Nominal current

0.36 A

Nominal wattage + Power loss

80.00 W

Power factor λ [PIM]

0.98

Luminous flux at 35 °C

3100 lm

Number of lighting outlets

2

ECG_1.1 Ambient temperature for lifespan

40 °C

ECG_1.2 Ambient temperature for lifespan

50 °C

ECG_1.3 Ambient temperature for lifespan

58 °C

ECG_2.1 Tc point temperature for lifespa

60 °C

ECG_2.2 Tc point temperature for lifespa

70 °C

ECG_2.3 Tc point temperature for lifespa

75 °C

ECG_3.1 Temperature dependent lifespan

70000 h

ECG_3.2 Temperature dependent lifespan

40000 h

ECG_3.3 Temperature dependent lifespan

30000 h

L 18 W

Nominal current

0.17 A

Nominal wattage + Power loss

39.00 W

Power factor λ [PIM]

0.95

Luminous flux at 35 °C

1350 lm

Number of lighting outlets

2

ECG_1.1 Ambient temperature for lifespan

40 °C

ECG_1.2 Ambient temperature for lifespan

50 °C

ECG_1.3 Ambient temperature for lifespan

60 °C

ECG_2.1 Tc point temperature for lifespa

50 °C

ECG_2.2 Tc point temperature for lifespa

60 °C

ECG_2.3 Tc point temperature for lifespa

70 °C

ECG_3.1 Temperature dependent lifespan

100000 h

ECG_3.2 Temperature dependent lifespan

90000 h

ECG_3.3 Temperature dependent lifespan

50000 h

L 23 W

Nominal current

0.26 A

Nominal wattage + Power loss

59.30 W

Luminous flux at 25 °C

1900 lm

Number of lighting outlets

1

L 30 W

Nominal current

0.27 A

Nominal wattage + Power loss

63.00 W

Power factor λ [PIM]

0.98

Luminous flux at 25 °C

2350 lm

Number of lighting outlets

2

ECG_1.1 Ambient temperature for lifespan

40 °C

ECG_1.2 Ambient temperature for lifespan

50 °C

ECG_1.3 Ambient temperature for lifespan

60 °C

ECG_2.1 Tc point temperature for lifespa

55 °C

ECG_2.2 Tc point temperature for lifespa

65 °C

ECG_2.3 Tc point temperature for lifespa

75 °C

ECG_3.1 Temperature dependent lifespan

100000 h

ECG_3.2 Temperature dependent lifespan

60000 h

ECG_3.3 Temperature dependent lifespan

40000 h

L 36 W

Nominal current

0.31 A

Nominal wattage + Power loss

70.00 W

Power factor λ [PIM]

0.98

Luminous flux at 35 °C

3200 lm

Number of lighting outlets

2

ECG_1.1 Ambient temperature for lifespan

40 °C

ECG_1.2 Ambient temperature for lifespan

50 °C

ECG_1.3 Ambient temperature for lifespan

60 °C

ECG_2.1 Tc point temperature for lifespa

55 °C

ECG_2.2 Tc point temperature for lifespa

65 °C

ECG_2.3 Tc point temperature for lifespa

75 °C

ECG_3.1 Temperature dependent lifespan

100000 h

ECG_3.2 Temperature dependent lifespan

60000 h

ECG_3.3 Temperature dependent lifespan

30000 h

Information about Family

Whether you are installing a new lighting system, or looking for an ECG replacement for modernization of an existing system, consider the QUICKTRONIC FIT 5/8. Available in a range of variants, it features lamp start with optimum filament preheating, and automatic shutoff of defective lamps and at the end of life. Use it with luminaires of protection class I in open plan office lighting, corridors and storage rooms, strip lighting and public buildings. Its benefits include the ability to withstand frequent on / off switching without damage, long lamp life, very high energy efficiency thanks to cutoff technology, and automatic restart after lamp replacement If your LMS includes motion sensors, this ECG provides perfect lamp starts. The QUICKTRONIC FIT 5/8 has a system certified by VDE/VDE MC, assuring you of its quality.
Product family features
  • Supply voltage: 220…240 V
  • Line voltage: 198…264 V
  • Line frequency: 50 Hz | 60 Hz
  • Lamp start with optimum filament preheating
  • Energy Efficiency Index EEI: A2
  • Automatic shutdown of defective lamps and at end of life (EoL T.2)
  • Lamp operation: to EN 60929
  • Safety: to EN 61347-2-3
Ecodesign regulation information:
Separate control gear and light sources must be disposed of at certified disposal companies in accordance with Directive 2012/19/EU (WEEE) in the EU and with Waste Electrical and Electronic Equipment (WEEE) Regulations 2013 in the UK. For this purpose, collection points for recycling centres and take-back systems (CRSO) are available from retailers or private disposal companies, which accept separate control gear and light sources free of charge. In this way, raw materials are conserved and materials are recycled.

Products

Sort by:
Product
Height
Dimmable
ECG lifetime
Length
Width
Data sheet
QT-FIT 5/8 1X18…39
21.0 mm No 50000 h 280.0 mm 30.0 mm
QT-FIT 5/8 1X54…58
21.0 mm No 50000 h 280.0 mm 30.0 mm
QT-FIT 5/8 2X18…39
21.0 mm No 50000 h 280.0 mm 30.0 mm
QT-FIT 5/8 2X54…58
21.0 mm No 50000 h 280.0 mm 30.0 mm