QT-FIT8 3X18,4X18
Product family benefits
- Long lamp life
- No adverse effect from frequent on/off switching
- Automatic restart after lamp replacement
- Perfect lamp start for applications with motion sensors
- VDE/VDE EMC certified system
- Very high energy efficiency due to cut-off technology
Areas of application
- Open-plan offices, corridors and storage rooms
- Public buildings
- Strip lighting
- Suitable for luminaires of protection class I
Technical Data
Electrical data
Input voltage AC
198 264 V
Nominal voltage
220 240 V
Mains frequency
50 60 Hz
Input voltage DC
185 264 V
Maximum output power
4 x 18 W
Efficiency in full-load
86 %
Operating frequency
40 50 kHz
Max. ECG no. on circuit breaker 10 A (B)
8
Max. ECG no. on circuit breaker 16 A (B)
13
Inrush current
15 A
Light technical data
Starting time
2.0 s
Dimensions & weight
Length
280.0 mm
Width
40.0 mm
Height
28.0 mm
Mounting hole spacing, length
270.0 mm
Product weight
219.00 g
Cable cross-section, output side
0.5 1.5 mm²
Cable cross-section, input side
0.5 1.5 mm²
Temperatures & operating conditions
Ambient temperature range
-15 +50 °C
Permitted rel. humidity during operation
5 85 %
Lifespan
ECG lifetime
50000 h
Additional product data
Suitable for lamp power (4 lamps)
18 W
Suitable for lamp power (3 lamps)
18 W
Capabilities
End of lamp life safety shutdown
EOL T.2
Suitable for fixtures with prot. class
I
Intended for no-load operation
No
Max. cable length to lamp/LED module
1.0 m / 1.5 m
Dimmable
No
Certificates & standards
Approval marks approval
VDE / VDE-EMC / ENEC 10 / CE
EEI Energy Label
A2
Standards
Acc. to EN 61347-2-3/Acc. to EN 60929/Acc. to EN 55015:2006 + A1:2007/Acc. to EN 61000-3-2/Acc. to EN 61547
Protection class
I
Type of protection
IP20
Logistical data
Commodity code
85041080900
Environmental information
Information according Art. 33 of EU Regulation (EC) 1907/2006 (REACh)
Date of Declaration
19-05-2023
Primary Article Identifier
4008321294302
Candidate List Substance 1
Lead
CAS No. of substance 1
7439-92-1
Safe Use Instruction
The identification of the Candidate List substance is sufficient to allow safe use of the article.
Declaration No. in SCIP database
83ce3568-1063-45e2-b372-cb9584c9fcee
Packaging information
EAN |
Unit |
Piece |
Dimension l x w x h |
Weight |
Volume |
---|---|---|---|---|---|
4008321294302 |
UNV
| 1 | 280mm x 40mm x 28mm | 219.00g | 0.31dm³ |
4008321294319 |
VS
| 20 | 303mm x 210mm x 132mm | 4574.00g | 8.40dm³ |
Downloads
Data sheets
Lamp-ECG Combination
L 18 W
Nominal current
0.25 A
Nominal wattage + Power loss
54.00 W
Power factor λ [PIM]
0.97
Luminous flux at 35 °C
1350 lm
Number of lighting outlets
3
ECG_1.1 Ambient temperature for lifespan
40 °C
ECG_1.2 Ambient temperature for lifespan
50 °C
ECG_1.3 Ambient temperature for lifespan
60 °C
ECG_2.1 Tc point temperature for lifespa
50 °C
ECG_2.2 Tc point temperature for lifespa
60 °C
ECG_2.3 Tc point temperature for lifespa
65 °C
ECG_3.1 Temperature dependent lifespan
100000 h
ECG_3.2 Temperature dependent lifespan
100000 h
ECG_3.3 Temperature dependent lifespan
60000 h
L 18 W
Nominal current
0.33 A
Nominal wattage + Power loss
74.00 W
Power factor λ [PIM]
0.99
Luminous flux at 35 °C
1350 lm
Number of lighting outlets
4
ECG_1.1 Ambient temperature for lifespan
40 °C
ECG_1.2 Ambient temperature for lifespan
50 °C
ECG_1.3 Ambient temperature for lifespan
60 °C
ECG_2.1 Tc point temperature for lifespa
55 °C
ECG_2.2 Tc point temperature for lifespa
60 °C
ECG_2.3 Tc point temperature for lifespa
70 °C
ECG_3.1 Temperature dependent lifespan
100000 h
ECG_3.2 Temperature dependent lifespan
90000 h
ECG_3.3 Temperature dependent lifespan
50000 h
Information about Family
If you are upgrading an existing system, or creating a new light installation with T8 lamps, consider the QUICKTRONIC FIT 8 ECG. It has lamp start with optimum filament preheating, an energy efficiency index of A2 and automatic shutoff of defective lamps and at end of life, and you can use it with luminaires of protection class I for open plan office lighting, corridors, storage rooms, strip lighting and in public buildings. If your LMS uses motion sensors, this ECcG will give you perfect lamp start, and withstand frequent on/off switching. The QUICKTRONIC FIT 8 ECG for T8 lamps enhances lamp life, provides automatic restart after lamp replacement, and is highly energy efficient thanks to its cutoff technology. This ECG has a VDE/VDE MC certified system, assuring you of its quality.
Product family features
- Supply voltage: 220 240 V
- Line voltage: 198 264 V
- Line frequency: 50 Hz | 60 Hz
- Lamp start with optimum filament preheating
- Energy Efficiency Index EEI: A2
- Automatic shutdown of defective lamps and at end of life (EoL T.2)
- Lamp operation: to EN 60929
- Safety: to EN 61347-2-3
Ecodesign regulation information:
Separate control gear and light sources must be disposed of at certified disposal companies in accordance with Directive 2012/19/EU (WEEE) in the EU and with Waste Electrical and Electronic Equipment (WEEE) Regulations 2013 in the UK. For this purpose, collection points for recycling centres and take-back systems (CRSO) are available from retailers or private disposal companies, which accept separate control gear and light sources free of charge. In this way, raw materials are conserved and materials are recycled.
Separate control gear and light sources must be disposed of at certified disposal companies in accordance with Directive 2012/19/EU (WEEE) in the EU and with Waste Electrical and Electronic Equipment (WEEE) Regulations 2013 in the UK. For this purpose, collection points for recycling centres and take-back systems (CRSO) are available from retailers or private disposal companies, which accept separate control gear and light sources free of charge. In this way, raw materials are conserved and materials are recycled.
Products
Product |
|
|
|
|
|
Data sheet | ||
---|---|---|---|---|---|---|---|---|
![]() |
QT-FIT8 1X18
|
28.0 mm | No | 50000 h | 280.0 mm | 30.0 mm | ||
![]() |
QT-FIT8 1X36
|
28.0 mm | No | 50000 h | 280.0 mm | 30.0 mm | ||
![]() |
QT-FIT8 1X58
70
|
28.0 mm | No | 50000 h | 280.0 mm | 30.0 mm | ||
![]() |
QT-FIT8 2X18
|
28.0 mm | No | 50000 h | 360.0 mm | 30.0 mm | ||
![]() |
QT-FIT8 2X36
|
28.0 mm | No | 50000 h | 360.0 mm | 30.0 mm | ||
![]() |
QT-FIT8 2X58
70
|
28.0 mm | No | 50000 h | 360.0 mm | 30.0 mm | ||
![]() |
QT-FIT8 2X58
|
28.0 mm | No | 50000 h | 360.0 mm | 30.0 mm | ||
![]() |
QT-FIT8 3X18,4X18
|
28.0 mm | No | 50000 h | 280.0 mm | 40.0 mm | ||
![]() |
QT-FIT8 3X36
|
28.0 mm | No | 50000 h | 280.0 mm | 40.0 mm |