QTi DALI-T/E 2X18 42 DIM
- System+ Guarantee available
- Easy integration in luminaire thanks to same dimensions like DALI GI ECG
- Control via the DALI interface
- Compliance with the DALI Version-1 and IEC 60929
- Control input protected against overvoltage and polarity reversal (OSRAM ECG)
- Manual dimming without controller and with standard switches
- Including memory function (double click) and soft start
- Suitable for use in emergency lighting systems as per EN 50172/DIN VDE 0108-100
- Installation in emergency lighting systems according to IEC 61347-2-3, appendix J
- Open-plan offices, corridors and storage rooms
- Public buildings
- Suitable for luminaires of protection class I
References / Links
For more information on the system guarantee and the terms and conditions of the guarantee visit www.osram.com/system-guarantee
Technical Data
Electrical data
Nominal voltage
220 240 V
Mains frequency
50 60 Hz
Input voltage DC
154 276 V
Maximum output power
2 x 42 W
Efficiency in full-load
95 %
Networked standby power
<0.50 W
Operating frequency
42 140 kHz
Max. ECG no. on circuit breaker 10 A (B)
8
Max. ECG no. on circuit breaker 16 A (B)
13
Inrush current
45 A
Light technical data
Starting time
0.6 s
Dimensions & weight
Length
123.0 mm
Width
79.0 mm
Height
33.0 mm
Mounting hole spacing, length
129.5 mm
Mounting hole spacing, width
67.0 mm
Product weight
247.00 g
Cable cross-section, input side
0.5 1.5 mm²
Temperatures & operating conditions
Ambient temperature range
+10 +50 °C
Permitted rel. humidity during operation
5 85 %
Lifespan
ECG lifetime
100000 h
Additional product data
Product remark
Optional cable clamp, see chapter ECG mountings - cable clamp
Suitable for lamp power (2 lamps)
18 42 W
Capabilities
Dimming interface
DALI / Touch DIM / Touch DIM Sensor
Dimming range
3 100 %
Dimmable
Yes
Overheating protection
Yes
Suitable for fixtures with prot. class
I
End of lamp life safety shutdown
EOL T.2
Intended for no-load operation
No
Max. cable length to lamp/LED module
0.5 m
Certificates & standards
Approval marks approval
VDE / VDE-EMC / EL / EAC / RCM / CCC
Standards
Acc. to EN 55015/Acc. to EN 61000-3-2/Acc. to EN 61547/Acc. to EN 61347-2-3/Acc. to EN 60929/Acc. to EN 55015:2006 + A1:2007/Acc. to EN 61000-3-2/Acc. to EN 61547/Acc. to IEC 62386-101:Ed1/Acc. to IEC 62386-102:Ed1
Protection class
I
Type of protection
IP20
EEI Energy Label
A1 BAT
Logistical data
Commodity code
850410809000
Environmental information
Information according Art. 33 of EU Regulation (EC) 1907/2006 (REACh)
Date of Declaration
14-04-2022
Primary Article Identifier
4008321060822
Candidate List Substance 1
Lead
CAS No. of substance 1
7439-92-1
Safe Use Instruction
The identification of the Candidate List substance is sufficient to allow safe use of the article.
Declaration No. in SCIP database
27b8c0c2-6392-4f67-8ee2-09e5d9bb1b49
Packaging information
EAN |
Unit |
Piece |
Dimension l x w x h |
Weight |
Volume |
---|---|---|---|---|---|
4008321060822 |
UNV
| 1 | |||
4008321060839 |
VS
| 20 | 428mm x 78mm x 257mm | 4700.00g | 8.58dm³ |
Downloads
Lamp-ECG Combination
DULUX D/E 18 W
Nominal current
0.17 A
Nominal wattage + Power loss
38.00 W
Power factor λ [PIM]
0.95
Luminous flux at 25 °C
2*1200 lm
Ambient temperature range [PIM] REM
Operation at up to -20 °C for all QTi (DALI) DIM-ECG possible. Lowest dimming position must be limited. Details see technical dimming brochure.
Number of lighting outlets
2
DULUX D/E 26 W
Nominal current
0.25 A
Nominal wattage + Power loss
56.00 W
Power factor λ [PIM]
0.98
Luminous flux at 25 °C
2*1800 lm
Ambient temperature range [PIM] REM
Operation at up to -20 °C for all QTi (DALI) DIM-ECG possible. Lowest dimming position must be limited. Details see technical dimming brochure.
Number of lighting outlets
2
ECG_1.1 Ambient temperature for lifespan
40 °C
ECG_1.2 Ambient temperature for lifespan
50 °C
ECG_1.3 Ambient temperature for lifespan
60 °C
ECG_2.1 Tc point temperature for lifespa
60 °C
ECG_2.2 Tc point temperature for lifespa
70 °C
ECG_2.3 Tc point temperature for lifespa
75 °C
ECG_3.1 Temperature dependent lifespan
100000 h
ECG_3.2 Temperature dependent lifespan
100000 h
ECG_3.3 Temperature dependent lifespan
80000 h
DULUX L 24 W
Nominal current
0.22 A
Nominal wattage + Power loss
51.00 W
Power factor λ [PIM]
0.97
Luminous flux at 35 °C
1200 lm
Ambient temperature range [PIM] REM
Operation at up to -20 °C for all QTi (DALI) DIM-ECG possible. Lowest dimming position must be limited. Details see technical dimming brochure.
Number of lighting outlets
2
ECG_1.1 Ambient temperature for lifespan
40 °C
ECG_1.2 Ambient temperature for lifespan
50 °C
ECG_1.3 Ambient temperature for lifespan
60 °C
ECG_2.1 Tc point temperature for lifespa
60 °C
ECG_2.2 Tc point temperature for lifespa
70 °C
ECG_2.3 Tc point temperature for lifespa
75 °C
ECG_3.1 Temperature dependent lifespan
100000 h
ECG_3.2 Temperature dependent lifespan
100000 h
ECG_3.3 Temperature dependent lifespan
80000 h
DULUX L 40 W
Nominal current
0.38 A
Nominal wattage + Power loss
87.00 W
Power factor λ [PIM]
0.99
Luminous flux at 35 °C
3500 lm
Ambient temperature range [PIM] REM
Operation at up to -20 °C for all QTi (DALI) DIM-ECG possible. Lowest dimming position must be limited. Details see technical dimming brochure.
Number of lighting outlets
2
ECG_1.1 Ambient temperature for lifespan
40 °C
ECG_1.2 Ambient temperature for lifespan
50 °C
ECG_1.3 Ambient temperature for lifespan
60 °C
ECG_2.1 Tc point temperature for lifespa
60 °C
ECG_2.2 Tc point temperature for lifespa
70 °C
ECG_2.3 Tc point temperature for lifespa
75 °C
ECG_3.1 Temperature dependent lifespan
100000 h
ECG_3.2 Temperature dependent lifespan
100000 h
ECG_3.3 Temperature dependent lifespan
80000 h
DULUX T/E 18 W
Nominal current
0.17 A
Nominal wattage + Power loss
38.00 W
Power factor λ [PIM]
0.95
Luminous flux at 25 °C
1200 lm
Ambient temperature range [PIM] REM
Operation at up to -20 °C for all QTi (DALI) DIM-ECG possible. Lowest dimming position must be limited. Details see technical dimming brochure.
Number of lighting outlets
2
ECG_1.1 Ambient temperature for lifespan
40 °C
ECG_1.2 Ambient temperature for lifespan
50 °C
ECG_1.3 Ambient temperature for lifespan
60 °C
ECG_2.1 Tc point temperature for lifespa
55 °C
ECG_2.2 Tc point temperature for lifespa
65 °C
ECG_2.3 Tc point temperature for lifespa
70 °C
ECG_3.1 Temperature dependent lifespan
100000 h
ECG_3.2 Temperature dependent lifespan
100000 h
ECG_3.3 Temperature dependent lifespan
100000 h
DULUX T/E 26 W
Nominal current
0.25 A
Nominal wattage + Power loss
56.00 W
Power factor λ [PIM]
0.98
Luminous flux at 25 °C
1800 lm
Ambient temperature range [PIM] REM
Operation at up to -20 °C for all QTi (DALI) DIM-ECG possible. Lowest dimming position must be limited. Details see technical dimming brochure.
Number of lighting outlets
2
ECG_1.1 Ambient temperature for lifespan
40 °C
ECG_1.2 Ambient temperature for lifespan
50 °C
ECG_1.3 Ambient temperature for lifespan
60 °C
ECG_2.1 Tc point temperature for lifespa
60 °C
ECG_2.2 Tc point temperature for lifespa
70 °C
ECG_2.3 Tc point temperature for lifespa
75 °C
ECG_3.1 Temperature dependent lifespan
100000 h
ECG_3.2 Temperature dependent lifespan
100000 h
ECG_3.3 Temperature dependent lifespan
80000 h
DULUX T/E 32 W
Nominal current
0.30 A
Nominal wattage + Power loss
69.00 W
Power factor λ [PIM]
0.99
Luminous flux at 25 °C
2400 lm
Ambient temperature range [PIM] REM
Operation at up to -20 °C for all QTi (DALI) DIM-ECG possible. Lowest dimming position must be limited. Details see technical dimming brochure.
Number of lighting outlets
2
DULUX T/E 42 W
Nominal current
0.39 A
Nominal wattage + Power loss
90.00 W
Power factor λ [PIM]
0.99
Luminous flux at 25 °C
3200 lm
Ambient temperature range [PIM] REM
Operation at up to -20 °C for all QTi (DALI) DIM-ECG possible. Lowest dimming position must be limited. Details see technical dimming brochure.
Number of lighting outlets
2
ECG_1.1 Ambient temperature for lifespan
40 °C
ECG_1.2 Ambient temperature for lifespan
50 °C
ECG_1.3 Ambient temperature for lifespan
60 °C
ECG_2.1 Tc point temperature for lifespa
60 °C
ECG_2.2 Tc point temperature for lifespa
70 °C
ECG_2.3 Tc point temperature for lifespa
75 °C
ECG_3.1 Temperature dependent lifespan
100000 h
ECG_3.2 Temperature dependent lifespan
100000 h
ECG_3.3 Temperature dependent lifespan
80000 h
FC 22 W
Nominal current
0.22 A
Nominal wattage + Power loss
51.00 W
Power factor λ [PIM]
0.97
Luminous flux at 35 °C
1800 lm
Ambient temperature range [PIM] REM
Operation at up to -20 °C for all QTi (DALI) DIM-ECG possible. Lowest dimming position must be limited. Details see technical dimming brochure.
Number of lighting outlets
2
ECG_1.1 Ambient temperature for lifespan
40 °C
ECG_1.2 Ambient temperature for lifespan
50 °C
ECG_1.3 Ambient temperature for lifespan
60 °C
ECG_2.1 Tc point temperature for lifespa
60 °C
ECG_2.2 Tc point temperature for lifespa
70 °C
ECG_2.3 Tc point temperature for lifespa
75 °C
ECG_3.1 Temperature dependent lifespan
100000 h
ECG_3.2 Temperature dependent lifespan
100000 h
ECG_3.3 Temperature dependent lifespan
80000 h
FC 40 W
Nominal current
0.38 A
Nominal wattage + Power loss
87.00 W
Power factor λ [PIM]
0.99
Luminous flux at 35 °C
3200 lm
Ambient temperature range [PIM] REM
Operation at up to -20 °C for all QTi (DALI) DIM-ECG possible. Lowest dimming position must be limited. Details see technical dimming brochure.
Number of lighting outlets
2
ECG_1.1 Ambient temperature for lifespan
40 °C
ECG_1.2 Ambient temperature for lifespan
50 °C
ECG_1.3 Ambient temperature for lifespan
60 °C
ECG_2.1 Tc point temperature for lifespa
60 °C
ECG_2.2 Tc point temperature for lifespa
70 °C
ECG_2.3 Tc point temperature for lifespa
75 °C
ECG_3.1 Temperature dependent lifespan
100000 h
ECG_3.2 Temperature dependent lifespan
100000 h
ECG_3.3 Temperature dependent lifespan
80000 h
Information about Family
- Corridor function for direct connection of ECG to common motion sensor
- Corridor function with pre-programmed light program
- Touch DIM function for free parameterization of light value and turn on time
- Fit for SMART GRID for feedback of consumed mains power and lamp operating hours
- Fit for emergency function for automatic detection of emergency lighting by ECG
- Very low standby power consumption: < 0.5 W
- Lifetime: > 100,000 h (for T = 65 °C at Tc)
- Very high number of switching cycles: up to 300,000
- Dimming range: 1 100 % (3 100 % with compact fluorescent lamp)
- POWER2LAMP function for optimal matching of ECG power to lamp during lamp lifetime
- Line frequency: 0 Hz, 50 60 Hz, rectified AC
Separate control gear and light sources must be disposed of at certified disposal companies in accordance with Directive 2012/19/EU (WEEE) in the EU and with Waste Electrical and Electronic Equipment (WEEE) Regulations 2013 in the UK. For this purpose, collection points for recycling centres and take-back systems (CRSO) are available from retailers or private disposal companies, which accept separate control gear and light sources free of charge. In this way, raw materials are conserved and materials are recycled.
Products
Product |
|
|
|
|
|
Data sheet | ||
---|---|---|---|---|---|---|---|---|
![]() |
QTi DALI-T/E 1x18
57 DIM
|
79.0 mm | 33.0 mm | Yes | DALI / Touch DIM / Touch DIM Sensor | 3 100 % | ||
![]() |
QTi DALI-T/E 2X18
42 DIM
|
79.0 mm | 33.0 mm | Yes | DALI / Touch DIM / Touch DIM Sensor | 3 100 % |