1X18…57 DIM

Product family benefits
  • Same luminous flux with direct and alternating current
  • Perfect lamp start for applications with motion sensors
  • Dimming of amalgam lamps without flickering or reduced lifespan
  • Very high efficiency thanks to cut-off technology
  • Automatic restart after lamp replacement
  • ECGs comply with MINERGIE standard due to very low standby consumption
  • Configurable emergency power characteristics
  • Control via the 1…10 V interface
Areas of application
  • Suitable for use in emergency lighting systems as per EN 50172/DIN VDE 0108-100
  • Industry
  • Open-plan offices, corridors and storage rooms
  • Public buildings
  • Suitable for luminaires of protection class I

Technical Data

Electrical data

Nominal voltage

220…240 V

Mains frequency

50…60 Hz

Input voltage DC

154…276 V

Maximum output power

57 W

Efficiency in full-load

90 %

at 230 V, 50 Hz

Operating frequency

42…140 kHz

Max. ECG no. on circuit breaker 10 A (B)

12

Type B

Max. ECG no. on circuit breaker 16 A (B)

19

Type B

Inrush current

30 A

Light technical data

Starting time

0.6 s

Optimized preheat start

Dimensions & weight

Length

123.0 mm

Width

79.0 mm

Height

33.0 mm

Mounting hole spacing, length

111.0 mm

Product weight

233.50 g

Temperatures & operating conditions

Ambient temperature range

+10…+50 °C

Permitted rel. humidity during operation

5…85 %

Maximum 56 days/year at 85 %

Lifespan

ECG lifetime

100000 h

At Tcase = 65°C at Tc point / 10% failure rate

Additional product data

Product remark

Optional cable clamp, see chapter ECG mountings - cable clamp

Suitable for lamp power (1 lamp)

18…57 W

Capabilities

Dimming interface

1…10 V

Dimming range

3…100 %

Dimmable

Yes

End of lamp life safety shutdown

EOL T.2

Suitable for fixtures with prot. class

I

Intended for no-load operation

No

Max. cable length to lamp/LED module

0.5 m

Certificates & standards

Approval marks – approval

VDE / VDE-EMC / EL / EAC / RCM / CCC

Standards

Acc. to EN 55015/Acc. to EN 61000-3-2/Acc. to EN 61547

EEI – Energy Label

A1 BAT

Type of protection

IP20

Protection class

I

Logistical data

Commodity code

850410809000

Environmental information


Information according Art. 33 of EU Regulation (EC) 1907/2006 (REACh)

Date of Declaration

14-04-2022

Primary Article Identifier

4008321060860

Candidate List Substance 1

Lead

CAS No. of substance 1

7439-92-1

Safe Use Instruction

The identification of the Candidate List substance is sufficient to allow safe use of the article.

Declaration No. in SCIP database

018a20d5-f22b-4789-94e9-e8e431f5aeff

Packaging information

EAN

Unit

Piece

Dimension l x w x h

Weight

Volume

4008321060860 UNV

Unpacked

1
4008321060877 VS

Shipping box

20 428mm x 78mm x 257mm 4380.00g 8.58dm³

Downloads

Lamp-ECG Combination
DULUX D/E 18 W

Nominal current

0.09 A

Nominal wattage + Power loss

20.00 W

Power factor λ [PIM]

0.95

Luminous flux at 25 °C

1200 lm

Ambient temperature range [PIM] REM

Operation at up to -20 °C for all QTi (DALI) DIM-ECG possible. Lowest dimming position must be limited. Details see technical dimming brochure.

Number of lighting outlets

1

DULUX D/E 26 W

Nominal current

0.13 A

Nominal wattage + Power loss

29.00 W

Power factor λ [PIM]

0.97

Luminous flux at 25 °C

1800 lm

Ambient temperature range [PIM] REM

Operation at up to -20 °C for all QTi (DALI) DIM-ECG possible. Lowest dimming position must be limited. Details see technical dimming brochure.

Number of lighting outlets

1

DULUX T/E 18 W

Nominal current

0.09 A

Nominal wattage + Power loss

20.00 W

Power factor λ [PIM]

0.95

Luminous flux at 25 °C

1200 lm

Ambient temperature range [PIM] REM

Operation at up to -20 °C for all QTi (DALI) DIM-ECG possible. Lowest dimming position must be limited. Details see technical dimming brochure.

Number of lighting outlets

1

DULUX T/E 26 W

Nominal current

0.13 A

Nominal wattage + Power loss

29.00 W

Power factor λ [PIM]

0.97

Luminous flux at 25 °C

1800 lm

Ambient temperature range [PIM] REM

Operation at up to -20 °C for all QTi (DALI) DIM-ECG possible. Lowest dimming position must be limited. Details see technical dimming brochure.

Number of lighting outlets

1

DULUX T/E 32 W

Nominal current

0.16 A

Nominal wattage + Power loss

36.00 W

Power factor λ [PIM]

0.98

Luminous flux at 25 °C

2400 lm

Ambient temperature range [PIM] REM

Operation at up to -20 °C for all QTi (DALI) DIM-ECG possible. Lowest dimming position must be limited. Details see technical dimming brochure.

Number of lighting outlets

1

DULUX T/E 42 W

Nominal current

0.21 A

Nominal wattage + Power loss

47.00 W

Power factor λ [PIM]

0.99

Luminous flux at 25 °C

3200 lm

Ambient temperature range [PIM] REM

Operation at up to -20 °C for all QTi (DALI) DIM-ECG possible. Lowest dimming position must be limited. Details see technical dimming brochure.

Number of lighting outlets

1

FC 22 W

Nominal current

0.12 A

Nominal wattage + Power loss

26.00 W

Power factor λ [PIM]

0.96

Luminous flux at 35 °C

1750 lm

Ambient temperature range [PIM] REM

Operation at up to -20 °C for all QTi (DALI) DIM-ECG possible. Lowest dimming position must be limited. Details see technical dimming brochure.

Number of lighting outlets

1

FC 40 W

Nominal current

0.20 A

Nominal wattage + Power loss

45.00 W

Power factor λ [PIM]

0.98

Luminous flux at 35 °C

3200 lm

Ambient temperature range [PIM] REM

Operation at up to -20 °C for all QTi (DALI) DIM-ECG possible. Lowest dimming position must be limited. Details see technical dimming brochure.

Number of lighting outlets

1

Information about Family

Product family features
  • Control via 1…10 V interface
  • Supply voltage: 220…240 V
  • Line frequency: 0 Hz | 50 Hz | 60 Hz
  • Line voltage: 198…264 V
  • Dimming range: 3…100 % luminous flux
  • Lamp start: within 0.6 s
  • Lifetime: > 100,000 h (for T = 65 °C at Tc)
  • Automatic shutdown of defective lamps and at end of life (EoL T.2)
  • Energy Efficiency Index EEI: A1 BAT
  • Overtemperature protection: Thermal management at high tc temperatures
  • Safety: to EN 61347-2-3
  • Lamp operation: to EN 60929
  • RI suppression: to EN 55015:2006+A1:2007+A2:2009/CISPR 15
  • Line harmonics according to EN 61000-3-2
  • Immunity according to EN 61547
Ecodesign regulation information:
Separate control gear and light sources must be disposed of at certified disposal companies in accordance with Directive 2012/19/EU (WEEE) in the EU and with Waste Electrical and Electronic Equipment (WEEE) Regulations 2013 in the UK. For this purpose, collection points for recycling centres and take-back systems (CRSO) are available from retailers or private disposal companies, which accept separate control gear and light sources free of charge. In this way, raw materials are conserved and materials are recycled.

Products

Sort by:
Product
Width
Dimmable
Height
Dimming interface
Dimming range
Data sheet
1X18…57 DIM
79.0 mm Yes 33.0 mm 1…10 V 3…100 %
2X18…42 DIM
79.0 mm Yes 33.0 mm 1…10 V 3…100 %