QT-M 2X26…42 S

Product family benefits
  • Long lamp life
  • No adverse effect from frequent on/off switching
  • Automatic restart after lamp replacement
  • Perfect lamp start for applications with motion sensors
  • Separate installations thanks to optional cable clamp for K2 and K3 casings
  • VDE/VDE EMC certified system
Areas of application
  • Public buildings
  • Sports halls and factories
  • Suitable for luminaires of protection class I

Technical Data

Electrical data

Input voltage AC

198…264 V

Nominal voltage

220…240 V

Mains frequency

50…60 Hz

Input voltage DC

176…254 V

Minimum voltage for lamp ignition: 198 V

Maximum output power

2 x 42 W

Efficiency in full-load

92 %

at 230 V, 50 Hz

Operating frequency

45 kHz

Approximately

Max. ECG no. on circuit breaker 10 A (B)

8

Type B

Max. ECG no. on circuit breaker 16 A (B)

13

Type B

Line current

0.39 A

Inrush current

28 A

Light technical data

Starting time

1.0 s

Dimensions & weight

Length

123.0 mm

Width

79.0 mm

Height

33.0 mm

Mounting hole spacing, length

111.0 mm

Product weight

280.00 g

Cable cross-section, input side

0.5…1.5 mm²

Cable cross-section, output side

0.5…1.5 mm²

Temperatures & operating conditions

Ambient temperature range

-20…+50 °C

Permitted rel. humidity during operation

5…85 %

Maximum 56 days/year at 85 %

Lifespan

ECG lifetime

50000 h

At Tcase = 75°C at Tc point / 10% failure rate

Additional product data

Suitable for lamp power (2 lamps)

26…42 W

Capabilities

End of lamp life safety shutdown

EOL T.2

Suitable for fixtures with prot. class

I / II

Dimmable

No

Max. cable length to lamp/LED module

2.0 m / 1.0 m

Intended for no-load operation

No

Certificates & standards

Approval marks – approval

VDE / VDE-EMC / ENEC 10 / GOST / RCM

EEI – Energy Label

A2

Standards

Acc. to EN 55015/Acc. to EN 61547/Acc. to EN 61000-3-2/IEC 61000-3-2

Type of protection

IP20

Protection class

I

Logistical data

Commodity code

85041080900

Environmental information


Information according Art. 33 of EU Regulation (EC) 1907/2006 (REACh)

Date of Declaration

19-05-2023

Primary Article Identifier

4008321110022

Candidate List Substance 1

Lead

CAS No. of substance 1

7439-92-1

Safe Use Instruction

The identification of the Candidate List substance is sufficient to allow safe use of the article.

Declaration No. in SCIP database

211bb136-a02e-4a76-8c81-1897997ff9dd

Packaging information

EAN

Unit

Piece

Dimension l x w x h

Weight

Volume

4008321110022 UNV

Unpacked

1 123mm x 79mm x 33mm 280.00g 0.32dm³
4008321110039 VS

Shipping box

20 412mm x 260mm x 101mm 5958.00g 10.82dm³

Downloads

Lamp-ECG Combination
DULUX D/E 26 W

Nominal current

0.23 A

Nominal wattage + Power loss

54.00 W

Power factor λ [PIM]

0.97

Luminous flux at 25 °C

2*1800 lm

Number of lighting outlets

2

DULUX F 36 W

Nominal current

0.30 A

Nominal wattage + Power loss

70.00 W

Power factor λ [PIM]

0.97

Luminous flux at 35 °C

2700 lm

Number of lighting outlets

2

DULUX L 24 W

Nominal current

0.23 A

Nominal wattage + Power loss

54.00 W

Power factor λ [PIM]

0.97

Luminous flux at 35 °C

1750 lm

Number of lighting outlets

2

FC 22 W

Nominal current

0.36 A

Nominal wattage + Power loss

54.00 W

Power factor λ [PIM]

0.97

Luminous flux at 25 °C

1600 lm

Luminous flux at 35 °C

1600 lm

Number of lighting outlets

2

FC 40 W

Nominal current

0.36 A

Nominal wattage + Power loss

88.00 W

Power factor λ [PIM]

0.97

Luminous flux at 35 °C

3200 lm

Number of lighting outlets

2

HO 24 W

Nominal current

0.23 A

Nominal wattage + Power loss

54.00 W

Power factor λ [PIM]

0.97

Luminous flux at 35 °C

1750 lm

Number of lighting outlets

2

L 36 W

Nominal current

0.30 A

Nominal wattage + Power loss

70.00 W

Power factor λ [PIM]

0.97

Luminous flux at 35 °C

3200 lm

Number of lighting outlets

2

Information about Family

QUICKTRONIC MULTIWATT ECG is designed for use with compact fluorescent lamps and comes in a choice of three variants, so you can select precisely the version you need for your professional lighting project. It features lamp start with optimum filament preheating and has an energy efficiency index of A2. Use it with luminaires of protection class I in public buildings, sports halls and industrial lighting applications such as factories. This ECG gives you perfect lamp start in applications using motion sensors, no adverse effects from frequent on/off switching and you can install it independently using the cable clamp for K2 and K3 casings.
Product family features
  • Supply voltage: 220…240 V
  • Line voltage: 198…264 V
  • Line frequency: 0 Hz | 50 Hz | 60 Hz
  • Lamp start with optimum filament preheating
  • Energy Efficiency Index EEI: A2
  • Automatic shutdown of defective lamps and at end of life (EoL T.2)
  • Lamp operation: to EN 60929
  • Safety: to EN 61347-2-3
Ecodesign regulation information:
Separate control gear and light sources must be disposed of at certified disposal companies in accordance with Directive 2012/19/EU (WEEE) in the EU and with Waste Electrical and Electronic Equipment (WEEE) Regulations 2013 in the UK. For this purpose, collection points for recycling centres and take-back systems (CRSO) are available from retailers or private disposal companies, which accept separate control gear and light sources free of charge. In this way, raw materials are conserved and materials are recycled.

Products

Sort by:
Product
Height
Dimmable
ECG lifetime
Length
Width
Data sheet
QT-M 2X26…42 S
33.0 mm No 50000 h 123.0 mm 79.0 mm
QTP-M 1X26…42
31.0 mm No 50000 h 103.0 mm 67.0 mm
QTP-M 2X26…32
33.0 mm No 50000 h 123.0 mm 79.0 mm