QTP5 3X14,4X14
Product family benefits
- Long lamp life
- No adverse effect from frequent on/off switching
- Perfect lamp start for applications with motion sensors
- Automatic restart after lamp replacement
- VDE/VDE EMC certified system
- Very high energy efficiency due to cut-off technology
Areas of application
- Emergency lighting systems acc. to EN 50172 / DIN VDE 0108-100
- Industry
- Open-plan offices, corridors and storage rooms
- Public buildings
- Sports halls and factories
- Strip lighting
- Suitable for emergency lighting (DC operation)
- Modernization of existing systems
- Suitable for luminaires of protection classes I and II
Technical Data
Electrical data
Nominal voltage
220 240 V
Mains frequency
50 60 Hz
Input voltage DC
176 276 V
Maximum output power
4 x 14 W
Efficiency in full-load
90 %
Operating frequency
40 50 kHz
Max. ECG no. on circuit breaker 10 A (B)
12
Max. ECG no. on circuit breaker 16 A (B)
19
Inrush current
40 A
Light technical data
Starting time
1.0 s
Dimensions & weight
Length
280.0 mm
Width
40.0 mm
Height
21.0 mm
Mounting hole spacing, length
270.0 mm
Product weight
211.00 g
Temperatures & operating conditions
Ambient temperature range
-20 +50 °C
Permitted rel. humidity during operation
5 85 %
Lifespan
ECG lifetime
100000 h
Additional product data
Suitable for lamp power (3 lamps)
14 W
Suitable for lamp power (4 lamps)
14 W
Capabilities
Suitable for fixtures with prot. class
I / II
End of lamp life safety shutdown
EOL T.2
Max. cable length to lamp/LED module
1.0 m / 1.5 m
Dimmable
No
Intended for no-load operation
No
Certificates & standards
Approval marks approval
VDE / VDE-EMC / ENEC 10 / CE
EEI Energy Label
A2 BAT
Standards
Acc. to EN 61347-2-3/Acc. to EN 55015:2006 + A1:2007/Acc. to EN 61000-3-2/Acc. to EN 61547
Type of protection
IP20
Protection class
III
Logistical data
Commodity code
850410809000
Environmental information
Information according Art. 33 of EU Regulation (EC) 1907/2006 (REACh)
Date of Declaration
19-05-2023
Primary Article Identifier
4008321484598
Candidate List Substance 1
Lead
CAS No. of substance 1
7439-92-1
Safe Use Instruction
The identification of the Candidate List substance is sufficient to allow safe use of the article.
Declaration No. in SCIP database
f9019c58-104f-4a0c-8a04-8ec379b0b928
Packaging information
EAN |
Unit |
Piece |
Dimension l x w x h |
Weight |
Volume |
---|---|---|---|---|---|
4008321484598 |
UNV
| 1 | 220.00g | ||
4008321484604 |
VS
| 20 | 304mm x 115mm x 171mm | 4475.00g | 5.98dm³ |
Downloads
Data sheets
Lamp-ECG Combination
HE 14 W
Nominal current
0.22 A
Nominal wattage + Power loss
63.00 W
Power factor λ [PIM]
0.97
Luminous flux at 25 °C
1200 lm
Luminous flux at 35 °C
1350 lm
Number of lighting outlets
4
HE 14 W
Nominal current
0.28 A
Nominal wattage + Power loss
48.00 W
Power factor λ [PIM]
0.95
Luminous flux at 25 °C
1200 lm
Luminous flux at 35 °C
1350 lm
Number of lighting outlets
3
Information about Family
If you need to install a new, or upgrade an existing lighting system with T5 lamps, the QUICKTRONIC PROFESSIONAL 5 ECG is a great option. It is available in several variants, so you can choose exactly the version you need for your own professional lighting project, and has an energy efficiency index of A2. Supply voltage is 220
250 V and line voltage is 198
264 V. You can use the QUICKTRONIC PROFESSIONAL 5 ECG with luminaires of protection classes I and II, in emergency lighting systems to EN 50172 / DIN VDE 0108-100, and it is good for industrial lighting, open plan office lighting, strip lighting, sports halls and factories. If you are modernizing an existing system, it is a great replacement ECG. Its cutoff technology gives this ECG excellent energy efficiency qualities, and it withstands frequent on/off switching.
Product family features
- Supply voltage: 220 240 V
- Line voltage: 198 264 V
- Line frequency: 0 Hz | 50 Hz | 60 Hz
- Lamp start with optimum filament preheating
- Lifetime: up to 100,000 h (temperature at Tc = 65 °C, max. 10 % failure rate)
- Energy Efficiency Index EEI: A2 BAT
- Automatic shutdown of defective lamps and at end of life (EoL T.2)
- Safety: to EN 61347-2-3
- Lamp operation: to EN 60929
Ecodesign regulation information:
Separate control gear and light sources must be disposed of at certified disposal companies in accordance with Directive 2012/19/EU (WEEE) in the EU and with Waste Electrical and Electronic Equipment (WEEE) Regulations 2013 in the UK. For this purpose, collection points for recycling centres and take-back systems (CRSO) are available from retailers or private disposal companies, which accept separate control gear and light sources free of charge. In this way, raw materials are conserved and materials are recycled.
Separate control gear and light sources must be disposed of at certified disposal companies in accordance with Directive 2012/19/EU (WEEE) in the EU and with Waste Electrical and Electronic Equipment (WEEE) Regulations 2013 in the UK. For this purpose, collection points for recycling centres and take-back systems (CRSO) are available from retailers or private disposal companies, which accept separate control gear and light sources free of charge. In this way, raw materials are conserved and materials are recycled.
Products
Product |
|
|
|
|
|
Data sheet | ||
---|---|---|---|---|---|---|---|---|
![]() |
QTP5 1X14
35
|
21.0 mm | No | 100000 h | 280.0 mm | 30.0 mm | ||
![]() |
QTP5 1X49
|
21.0 mm | No | 100000 h | 280.0 mm | 30.0 mm | ||
![]() |
QTP5 1X80
|
21.0 mm | No | 100000 h | 360.0 mm | 30.0 mm | ||
![]() |
QTP5 2X14
35
|
21.0 mm | No | 100000 h | 360.0 mm | 30.0 mm | ||
![]() |
QTP5 2X49
|
21.0 mm | No | 100000 h | 360.0 mm | 30.0 mm | ||
![]() |
QTP5 3X14,4X14
|
21.0 mm | No | 100000 h | 280.0 mm | 40.0 mm |