QTP-DL 2X36…40

Product family benefits
  • Long lamp life
  • No adverse effect from frequent on/off switching
  • Automatic restart after lamp replacement
  • Perfect lamp start for applications with motion sensors
  • VDE/VDE EMC certified system
  • Very high energy efficiency due to cut-off technology
Areas of application
  • Emergency lighting systems acc. to EN 50172 / DIN VDE 0108-100
  • Open-plan offices, corridors and storage rooms
  • Public buildings
  • Suitable for luminaires of protection classes I and II

Technical Data

Electrical data

Input voltage AC

198…264 V

Nominal voltage

220…240 V

Mains frequency

50…60 Hz

Input voltage DC

154…276 V

Minimum voltage for lamp ignition: 198 V

Maximum output power

2 x 40 W

Efficiency in full-load

91 %

at 230 V, 50 Hz

Operating frequency

45…50 kHz

Max. ECG no. on circuit breaker 10 A (B)

12

Type B

Max. ECG no. on circuit breaker 16 A (B)

19

Type B

Inrush current

23 A

Light technical data

Starting time

1.0 s

Dimensions & weight

Length

280.0 mm

Width

40.0 mm

Height

28.0 mm

Mounting hole spacing, length

270.0 mm

Product weight

290.00 g

Temperatures & operating conditions

Ambient temperature range

-20…+50 °C

Permitted rel. humidity during operation

5…85 %

Maximum 56 days/year at 85 %

Lifespan

ECG lifetime

50000 h

At Tcase = 75°C at Tc point / 10% failure rate

Additional product data

Suitable for lamp power (2 lamps)

36…40 W

Capabilities

End of lamp life safety shutdown

EOL T.2

Suitable for fixtures with prot. class

I / II

Intended for no-load operation

No

Dimmable

No

Max. cable length to lamp/LED module

2.0 m / 1.0 m

Certificates & standards

Approval marks – approval

VDE / VDE-EMC / ENEC 10 / GOST / RCM

EEI – Energy Label

A2 BAT

Standards

Acc. to EN 61347-2-3/Acc. to EN 60929/Acc. to EN 55015:2006 + A1:2007/Acc. to EN 61000-3-2/Acc. to EN 61547

Type of protection

IP20

Protection class

I

Logistical data

Commodity code

85041080900

Environmental information


Information according Art. 33 of EU Regulation (EC) 1907/2006 (REACh)

Date of Declaration

19-05-2023

Primary Article Identifier

4008321117922

Candidate List Substance 1

Lead

CAS No. of substance 1

7439-92-1

Safe Use Instruction

The identification of the Candidate List substance is sufficient to allow safe use of the article.

Declaration No. in SCIP database

0ddbf859-75ae-4110-8f39-1ad44cb7e2c0

Packaging information

EAN

Unit

Piece

Dimension l x w x h

Weight

Volume

4008321117922 UNV

Unpacked

1 280mm x 40mm x 28mm 290.00g 0.31dm³
4008321117939 VS

Shipping box

20 303mm x 210mm x 120mm 6153.00g 7.64dm³

Downloads

Lamp-ECG Combination
DULUX F 36 W

Nominal current

0.33 A

Nominal wattage + Power loss

68.00 W

Power factor λ [PIM]

0.99

Luminous flux at 35 °C

2800 lm

Number of lighting outlets

2

DULUX L 40 W

Nominal current

0.21 A

Nominal wattage + Power loss

90.00 W

Power factor λ [PIM]

0.99

Luminous flux at 35 °C

3650 lm

Number of lighting outlets

2

L 36 W

Nominal current

0.35 A

Nominal wattage + Power loss

80.50 W

Power factor λ [PIM]

0.99

Luminous flux at 35 °C

3400 lm

Number of lighting outlets

2

Information about Family

If you are creating or modernizing a light installation with compact fluorescent lamps (CFLs), QUICKTRONIC PROFESSIONAL DL is a great option. Its features include lamp start with optimum filament preheating, an extensive lifespan, auto shutoff when a lamp is defective or at end of life, and an energy efficiency index of A2. It is suitable for emergency lighting systems according to EN 50172 / DIN VDE 0108-100. Use it with luminaires of protection classes I and II for open plan office lighting, corridors, storage rooms and public buildings. The QUICKTRONIC PROFESSIONAL DL ECG gives you a range of key benefits; enhanced lamp life, automatic restart after lamp failure, perfect lamp start for light control applications with motion sensors, and very high energy efficiency.
Product family features
  • Supply voltage: 220…240 V
  • Line voltage: 198…264 V
  • Line frequency: 0 Hz | 50 Hz | 60 Hz
  • Lamp start with optimum filament preheating
  • Energy Efficiency Index EEI: A2 BAT
  • Automatic shutdown of defective lamps and at end of life (EoL T.2)
  • Lamp operation: to EN 60929
  • Safety: to EN 61347-2-3
Ecodesign regulation information:
Separate control gear and light sources must be disposed of at certified disposal companies in accordance with Directive 2012/19/EU (WEEE) in the EU and with Waste Electrical and Electronic Equipment (WEEE) Regulations 2013 in the UK. For this purpose, collection points for recycling centres and take-back systems (CRSO) are available from retailers or private disposal companies, which accept separate control gear and light sources free of charge. In this way, raw materials are conserved and materials are recycled.

Products

Sort by:
Product
Height
Dimmable
ECG lifetime
Length
Width
Data sheet
QTP-DL 2X36…40
28.0 mm No 50000 h 280.0 mm 40.0 mm
QTP-DL 2X55 GII