QTP-DL 2X36 40
Product family benefits
- Long lamp life
- No adverse effect from frequent on/off switching
- Automatic restart after lamp replacement
- Perfect lamp start for applications with motion sensors
- VDE/VDE EMC certified system
- Very high energy efficiency due to cut-off technology
Areas of application
- Emergency lighting systems acc. to EN 50172 / DIN VDE 0108-100
- Open-plan offices, corridors and storage rooms
- Public buildings
- Suitable for luminaires of protection classes I and II
Technical Data
Electrical data
Input voltage AC
198 264 V
Nominal voltage
220 240 V
Mains frequency
50 60 Hz
Input voltage DC
154 276 V
Maximum output power
2 x 40 W
Efficiency in full-load
91 %
Operating frequency
45 50 kHz
Max. ECG no. on circuit breaker 10 A (B)
12
Max. ECG no. on circuit breaker 16 A (B)
19
Inrush current
23 A
Light technical data
Starting time
1.0 s
Dimensions & weight
Length
280.0 mm
Width
40.0 mm
Height
28.0 mm
Mounting hole spacing, length
270.0 mm
Product weight
290.00 g
Temperatures & operating conditions
Ambient temperature range
-20 +50 °C
Permitted rel. humidity during operation
5 85 %
Lifespan
ECG lifetime
50000 h
Additional product data
Suitable for lamp power (2 lamps)
36 40 W
Capabilities
End of lamp life safety shutdown
EOL T.2
Suitable for fixtures with prot. class
I / II
Intended for no-load operation
No
Max. cable length to lamp/LED module
2.0 m / 1.0 m
Dimmable
No
Certificates & standards
Approval marks approval
VDE / VDE-EMC / ENEC 10 / GOST / RCM
EEI Energy Label
A2 BAT
Standards
Acc. to EN 61347-2-3/Acc. to EN 60929/Acc. to EN 55015:2006 + A1:2007/Acc. to EN 61000-3-2/Acc. to EN 61547
Protection class
I
Type of protection
IP20
Logistical data
Commodity code
85041080900
Environmental information
Information according Art. 33 of EU Regulation (EC) 1907/2006 (REACh)
Date of Declaration
19-05-2023
Primary Article Identifier
4008321117922
Candidate List Substance 1
Lead
CAS No. of substance 1
7439-92-1
Safe Use Instruction
The identification of the Candidate List substance is sufficient to allow safe use of the article.
Declaration No. in SCIP database
0ddbf859-75ae-4110-8f39-1ad44cb7e2c0
Packaging information
EAN |
Unit |
Piece |
Dimension l x w x h |
Weight |
Volume |
---|---|---|---|---|---|
4008321117922 |
UNV
| 1 | 280mm x 40mm x 28mm | 290.00g | 0.31dm³ |
4008321117939 |
VS
| 20 | 303mm x 210mm x 120mm | 6153.00g | 7.64dm³ |
Downloads
Data sheets
Lamp-ECG Combination
DULUX F 36 W
Nominal current
0.33 A
Nominal wattage + Power loss
68.00 W
Power factor λ [PIM]
0.99
Luminous flux at 35 °C
2800 lm
Number of lighting outlets
2
DULUX L 36 W
Nominal current
0.33 A
Nominal wattage + Power loss
68.00 W
Power factor λ [PIM]
0.99
Luminous flux at 35 °C
2900 lm
Number of lighting outlets
2
DULUX L 40 W
Nominal current
0.21 A
Nominal wattage + Power loss
90.00 W
Power factor λ [PIM]
0.99
Luminous flux at 35 °C
3650 lm
Number of lighting outlets
2
L 36 W
Nominal current
0.35 A
Nominal wattage + Power loss
80.50 W
Power factor λ [PIM]
0.99
Luminous flux at 35 °C
3400 lm
Number of lighting outlets
2
Information about Family
If you are creating or modernizing a light installation with compact fluorescent lamps (CFLs), QUICKTRONIC PROFESSIONAL DL is a great option. Its features include lamp start with optimum filament preheating, an extensive lifespan, auto shutoff when a lamp is defective or at end of life, and an energy efficiency index of A2. It is suitable for emergency lighting systems according to EN 50172 / DIN VDE 0108-100. Use it with luminaires of protection classes I and II for open plan office lighting, corridors, storage rooms and public buildings. The QUICKTRONIC PROFESSIONAL DL ECG gives you a range of key benefits; enhanced lamp life, automatic restart after lamp failure, perfect lamp start for light control applications with motion sensors, and very high energy efficiency.
Product family features
- Supply voltage: 220 240 V
- Line voltage: 198 264 V
- Line frequency: 0 Hz | 50 Hz | 60 Hz
- Lamp start with optimum filament preheating
- Energy Efficiency Index EEI: A2 BAT
- Automatic shutdown of defective lamps and at end of life (EoL T.2)
- Lamp operation: to EN 60929
- Safety: to EN 61347-2-3
Ecodesign regulation information:
Separate control gear and light sources must be disposed of at certified disposal companies in accordance with Directive 2012/19/EU (WEEE) in the EU and with Waste Electrical and Electronic Equipment (WEEE) Regulations 2013 in the UK. For this purpose, collection points for recycling centres and take-back systems (CRSO) are available from retailers or private disposal companies, which accept separate control gear and light sources free of charge. In this way, raw materials are conserved and materials are recycled.
Separate control gear and light sources must be disposed of at certified disposal companies in accordance with Directive 2012/19/EU (WEEE) in the EU and with Waste Electrical and Electronic Equipment (WEEE) Regulations 2013 in the UK. For this purpose, collection points for recycling centres and take-back systems (CRSO) are available from retailers or private disposal companies, which accept separate control gear and light sources free of charge. In this way, raw materials are conserved and materials are recycled.
Products
Product |
|
|
|
|
|
Data sheet | ||
---|---|---|---|---|---|---|---|---|
![]() |
QTP-DL 2X36
40
|
28.0 mm | No | 50000 h | 280.0 mm | 40.0 mm | ||
![]() |
QTP-DL 2X55 GII
|
21.0 mm | No | 50000 h | 360.0 mm | 30.0 mm |