QTP-T/E 1X18,2X18

Product family benefits
  • Long lamp life
  • No adverse effect from frequent on/off switching
  • Automatic restart after lamp replacement
  • Perfect lamp start for applications with motion sensors
  • Separate installations thanks to optional cable clamp for K2 and K3 casings
  • VDE/VDE EMC certified system
Areas of application
  • Emergency lighting systems acc. to EN 50172 / DIN VDE 0108-100
  • Public buildings
  • Sports halls and factories
  • Suitable for luminaires of protection class I

Technical Data

Electrical data

Input voltage AC

198…264 V

Nominal voltage

220…240 V

Mains frequency

50…60 Hz

Input voltage DC

176…264 V

Maximum output power

2 x 18 W

Efficiency in full-load

89 %

at 230 V, 50 Hz

Operating frequency

40…50 kHz

Max. ECG no. on circuit breaker 10 A (B)

17

Type B

Max. ECG no. on circuit breaker 16 A (B)

28

Type B

Light technical data

Starting time

1.0 s

Dimensions & weight

Length

103.0 mm

Width

67.0 mm

Height

31.0 mm

Mounting hole spacing, length

94.0 mm

Product weight

149.00 g

Cable cross-section, output side

0.5…1.5 mm²

Cable cross-section, input side

0.5…1.5 mm²

Temperatures & operating conditions

Ambient temperature range

-20…+50 °C

Permitted rel. humidity during operation

5…85 %

Maximum 56 days/year at 85 %

Lifespan

ECG lifetime

50000 h

At Tcase = 75°C at Tc point / 10% failure rate

Additional product data

Suitable for lamp power (1 lamp)

18 W

Suitable for lamp power (2 lamps)

18 W

Capabilities

End of lamp life safety shutdown

EOL T.2

Suitable for fixtures with prot. class

I / II

Max. cable length to lamp/LED module

2.0 m / 1.0 m

Intended for no-load operation

No

Dimmable

No

Certificates & standards

Approval marks – approval

VDE / VDE-EMC / ENEC 10 / GOST / RCM

EEI – Energy Label

A2 BAT

Standards

Acc. to EN 61347-2-3/Acc. to EN 60929/Acc. to EN 55015:2006 + A1:2007/Acc. to EN 61000-3-2/Acc. to EN 61547

Protection class

III

Type of protection

IP20

Logistical data

Commodity code

85041080900

Environmental information


Information according Art. 33 of EU Regulation (EC) 1907/2006 (REACh)

Date of Declaration

26-05-2023

Primary Article Identifier

4008321537065

Candidate List Substance 1

Lead

CAS No. of substance 1

7439-92-1

Safe Use Instruction

The identification of the Candidate List substance is sufficient to allow safe use of the article.

Declaration No. in SCIP database

8cd7a45f-abcc-438a-93aa-ff6c6a399b3a

Packaging information

EAN

Unit

Piece

Dimension l x w x h

Weight

Volume

4008321537065 UNV

Unpacked

1 103mm x 67mm x 31mm 149.00g 0.21dm³
4008321537072 VS

Shipping box

20 360mm x 230mm x 90mm 3266.00g 7.45dm³

Downloads

Lamp-ECG Combination
DULUX D/E 18 W

Nominal current

0.09 A

Nominal wattage + Power loss

19.00 W

Power factor λ [PIM]

0.90 c

Luminous flux at 25 °C

1*1200 lm

Number of lighting outlets

1

DULUX D/E 18 W

Nominal current

0.16 A

Nominal wattage + Power loss

36.00 W

Power factor λ [PIM]

0.98

Luminous flux at 25 °C

1200 lm

Number of lighting outlets

2

DULUX T/E 18 W

Nominal current

0.16 A

Nominal wattage + Power loss

36.00 W

Power factor λ [PIM]

0.98

Luminous flux at 25 °C

2*2200 lm

Number of lighting outlets

2

ECG_1.1 Ambient temperature for lifespan

40 °C

ECG_1.2 Ambient temperature for lifespan

50 °C

ECG_1.3 Ambient temperature for lifespan

60 °C

ECG_2.1 Tc point temperature for lifespa

55 °C

ECG_2.2 Tc point temperature for lifespa

65 °C

ECG_2.3 Tc point temperature for lifespa

70 °C

ECG_3.1 Temperature dependent lifespan

100000 h

ECG_3.2 Temperature dependent lifespan

100000 h

ECG_3.3 Temperature dependent lifespan

60000 h

DULUX T/E 18 W

Nominal current

0.09 A

Nominal wattage + Power loss

19.00 W

Power factor λ [PIM]

0.90 c

Luminous flux at 25 °C

1*1200 lm

Number of lighting outlets

1

Information about Family

If you need a high performance, energy efficient ECG to use with compact fluorescent lamps, the QUICKTRONIC PROFESSIONAL M, which is available in several variants, may be ideal. It gives you lamp start with optimum filament preheating, auto shutdown of defective lamps and at end of life, and an energy efficiency index of A2, and you can use it in emergency lighting systems to EN 50172 / DIN VDE 0108-100. Used with luminaires of protection class I, you may find it particularly useful for professional lighting systems in public buildings, sports halls and industrial lighting, including factories. QUICKTRONIC PROFESSIONAL M is a great addition to a light management system (LMS) and provides perfect lamp start for applications with motion sensors. Other benefits include its ability to resist frequent on/off switching, and long lamp life. You can install this ECG separately with the optional cable clamp for K2 and K3 casings.
Product family features
  • Supply voltage: 220…240 V
  • Line voltage: 198…264 V
  • Line frequency: 0 Hz | 50 Hz | 60 Hz
  • Lamp start with optimum filament preheating
  • Energy Efficiency Index EEI: A2
  • Automatic shutdown of defective lamps and at end of life (EoL T.2)
  • Lamp operation: to EN 60929
  • Safety: to EN 61347-2-3
Ecodesign regulation information:
Separate control gear and light sources must be disposed of at certified disposal companies in accordance with Directive 2012/19/EU (WEEE) in the EU and with Waste Electrical and Electronic Equipment (WEEE) Regulations 2013 in the UK. For this purpose, collection points for recycling centres and take-back systems (CRSO) are available from retailers or private disposal companies, which accept separate control gear and light sources free of charge. In this way, raw materials are conserved and materials are recycled.

Products

Sort by:
Product
Height
Dimmable
ECG lifetime
Length
Width
Data sheet
QTP-D/E 2X10…13
33.0 mm No 50000 h 123.0 mm 79.0 mm
QTP-T/E 1X18,2X18
31.0 mm No 50000 h 103.0 mm 67.0 mm
QTP-T/E 1X26…42,2X26
31.0 mm No 50000 h 103.0 mm 67.0 mm
QTP-D/E 1X10…13