QTP-OPTIMAL 2X18 40
- Long lamp life
- No adverse effect from frequent on/off switching
- Automatic restart after lamp replacement
- Perfect lamp start for applications with motion sensors
- VDE/VDE EMC certified system
- Very high energy efficiency due to cut-off technology
- Emergency lighting systems acc. to EN 50172 / DIN VDE 0108-100
- Industry
- Open-plan offices, corridors and storage rooms
- Public buildings
- Sports halls and factories
- Strip lighting
- Suitable for emergency lighting (DC operation)
- Modernization of existing systems
- Suitable for luminaires of protection classes I and II
Technical Data
Electrical data
Input voltage AC
198 264 V
Nominal voltage
220 240 V
Mains frequency
50 60 Hz
Input voltage DC
176 276 V
Maximum output power
2 x 40 W
Efficiency in full-load
91 %
Operating frequency
40 50 kHz
Max. ECG no. on circuit breaker 10 A (B)
12
Max. ECG no. on circuit breaker 16 A (B)
19
Inrush current
37 A
Light technical data
Starting time
1.5 s
Dimensions & weight
Length
360.0 mm
Width
30.0 mm
Height
21.0 mm
Mounting hole spacing, length
350.0 mm
Product weight
243.70 g
Temperatures & operating conditions
Ambient temperature range
-20 +50 °C
Permitted rel. humidity during operation
5 85 %
Lifespan
ECG lifetime
100000 h
Additional product data
Suitable for lamp power (2 lamps)
18 40 W
Predecessor EAN
4008321117885
Capabilities
Suitable for fixtures with prot. class
I / II
End of lamp life safety shutdown
EOL T.2
Intended for no-load operation
No
Dimmable
No
Max. cable length to lamp/LED module
2.0 m / 1.0 m
Certificates & standards
Approval marks approval
EL / VDE / ENEC 10 / VDE-EMC
EEI Energy Label
A2 BAT
Standards
Acc. to IEC 61347-2-3 / App. J/Acc. to EN 55015:2006 + A1:2007 + A2:2009/Acc. to IEC 61000-3-2/Acc. to IEC 61547
Type of protection
IP20
Protection class
I
Logistical data
Commodity code
85041080900
Environmental information
Information according Art. 33 of EU Regulation (EC) 1907/2006 (REACh)
Date of Declaration
19-05-2023
Primary Article Identifier
4008321873767
Candidate List Substance 1
Lead
CAS No. of substance 1
7439-92-1
Safe Use Instruction
The identification of the Candidate List substance is sufficient to allow safe use of the article.
Declaration No. in SCIP database
dfa68422-7944-47ea-b5d6-9a7a206b8d3c
Packaging information
EAN |
Unit |
Piece |
Dimension l x w x h |
Weight |
Volume |
---|---|---|---|---|---|
4008321873767 |
UNV
| 1 | 360mm x 30mm x 21mm | 244.00g | 0.23dm³ |
4008321873774 |
VS
| 20 | 385mm x 160mm x 100mm | 5045.00g | 6.16dm³ |
Downloads
Data sheets
Lamp-ECG Combination
DULUX F 18 W
Nominal current
0.16 A
Nominal wattage + Power loss
33.00 W
Power factor λ [PIM]
0.95
Luminous flux at 35 °C
1050 lm
Number of lighting outlets
2
DULUX F 24 W
Nominal current
0.23 A
Nominal wattage + Power loss
50.00 W
Power factor λ [PIM]
0.98
Luminous flux at 35 °C
1650 lm
Number of lighting outlets
2
ECG_1.1 Ambient temperature for lifespan
40 °C
ECG_1.2 Ambient temperature for lifespan
50 °C
ECG_1.3 Ambient temperature for lifespan
60 °C
ECG_2.1 Tc point temperature for lifespa
50 °C
ECG_2.2 Tc point temperature for lifespa
60 °C
ECG_2.3 Tc point temperature for lifespa
65 °C
ECG_3.1 Temperature dependent lifespan
100000 h
ECG_3.2 Temperature dependent lifespan
100000 h
ECG_3.3 Temperature dependent lifespan
90000 h
DULUX F 36 W
Nominal current
0.30 A
Nominal wattage + Power loss
67.00 W
Power factor λ [PIM]
0.98
Luminous flux at 35 °C
2700 lm
Number of lighting outlets
2
ECG_1.1 Ambient temperature for lifespan
40 °C
ECG_1.2 Ambient temperature for lifespan
50 °C
ECG_1.3 Ambient temperature for lifespan
60 °C
ECG_2.1 Tc point temperature for lifespa
55 °C
ECG_2.2 Tc point temperature for lifespa
60 °C
ECG_2.3 Tc point temperature for lifespa
70 °C
ECG_3.1 Temperature dependent lifespan
100000 h
ECG_3.2 Temperature dependent lifespan
100000 h
ECG_3.3 Temperature dependent lifespan
70000 h
DULUX L 18 W
Nominal current
0.16 A
Nominal wattage + Power loss
36.00 W
Power factor λ [PIM]
0.95
Luminous flux at 35 °C
1150 lm
Number of lighting outlets
2
ECG_1.1 Ambient temperature for lifespan
40 °C
ECG_1.2 Ambient temperature for lifespan
50 °C
ECG_1.3 Ambient temperature for lifespan
60 °C
ECG_2.1 Tc point temperature for lifespa
50 °C
ECG_2.2 Tc point temperature for lifespa
60 °C
ECG_2.3 Tc point temperature for lifespa
65 °C
ECG_3.1 Temperature dependent lifespan
100000 h
ECG_3.2 Temperature dependent lifespan
100000 h
ECG_3.3 Temperature dependent lifespan
90000 h
DULUX L 24 W
Nominal current
0.23 A
Nominal wattage + Power loss
53.00 W
Power factor λ [PIM]
0.98
Luminous flux at 35 °C
1750 lm
Number of lighting outlets
2
ECG_1.1 Ambient temperature for lifespan
40 °C
ECG_1.2 Ambient temperature for lifespan
50 °C
ECG_1.3 Ambient temperature for lifespan
60 °C
ECG_2.1 Tc point temperature for lifespa
50 °C
ECG_2.2 Tc point temperature for lifespa
60 °C
ECG_2.3 Tc point temperature for lifespa
70 °C
ECG_3.1 Temperature dependent lifespan
100000 h
ECG_3.2 Temperature dependent lifespan
100000 h
ECG_3.3 Temperature dependent lifespan
80000 h
DULUX L 36 W
Nominal current
0.30 A
Nominal wattage + Power loss
70.00 W
Power factor λ [PIM]
0.98
Luminous flux at 35 °C
2800 lm
Number of lighting outlets
2
ECG_1.1 Ambient temperature for lifespan
40 °C
ECG_1.2 Ambient temperature for lifespan
50 °C
ECG_1.3 Ambient temperature for lifespan
60 °C
ECG_2.1 Tc point temperature for lifespa
55 °C
ECG_2.2 Tc point temperature for lifespa
60 °C
ECG_2.3 Tc point temperature for lifespa
70 °C
ECG_3.1 Temperature dependent lifespan
100000 h
ECG_3.2 Temperature dependent lifespan
100000 h
ECG_3.3 Temperature dependent lifespan
70000 h
DULUX L 40 W
Nominal current
0.37 A
Nominal wattage + Power loss
88.00 W
Power factor λ [PIM]
0.99
Luminous flux at 35 °C
3500 lm
Number of lighting outlets
2
ECG_1.1 Ambient temperature for lifespan
40 °C
ECG_1.2 Ambient temperature for lifespan
60 °C
ECG_1.3 Ambient temperature for lifespan
60 °C
ECG_2.1 Tc point temperature for lifespa
60 °C
ECG_2.2 Tc point temperature for lifespa
65 °C
ECG_2.3 Tc point temperature for lifespa
75 °C
ECG_3.1 Temperature dependent lifespan
100000 h
ECG_3.2 Temperature dependent lifespan
90000 h
ECG_3.3 Temperature dependent lifespan
50000 h
HNS-L 18W 2G11
HNS-L 24W 2G11
HO 24 W
Nominal current
0.24 A
Nominal wattage + Power loss
49.20 W
Power factor λ [PIM]
0.98
Luminous flux at 35 °C
1750 lm
Number of lighting outlets
2
ECG_1.1 Ambient temperature for lifespan
40 °C
ECG_1.2 Ambient temperature for lifespan
50 °C
ECG_1.3 Ambient temperature for lifespan
60 °C
ECG_2.1 Tc point temperature for lifespa
50 °C
ECG_2.2 Tc point temperature for lifespa
60 °C
ECG_2.3 Tc point temperature for lifespa
70 °C
ECG_3.1 Temperature dependent lifespan
100000 h
ECG_3.2 Temperature dependent lifespan
100000 h
ECG_3.3 Temperature dependent lifespan
80000 h
HO 39 W
Nominal current
0.24 A
Nominal wattage + Power loss
82.90 W
Power factor λ [PIM]
0.99
Luminous flux at 35 °C
3100 lm
Number of lighting outlets
2
ECG_1.1 Ambient temperature for lifespan
40 °C
ECG_1.2 Ambient temperature for lifespan
60 °C
ECG_1.3 Ambient temperature for lifespan
60 °C
ECG_2.1 Tc point temperature for lifespa
60 °C
ECG_2.2 Tc point temperature for lifespa
65 °C
ECG_2.3 Tc point temperature for lifespa
75 °C
ECG_3.1 Temperature dependent lifespan
100000 h
ECG_3.2 Temperature dependent lifespan
90000 h
ECG_3.3 Temperature dependent lifespan
50000 h
L 15 W
Nominal current
0.15 A
Nominal wattage + Power loss
31.00 W
Power factor λ [PIM]
0.95
Luminous flux at 35 °C
950 lm
Number of lighting outlets
2
L 18 W
Nominal current
0.17 A
Nominal wattage + Power loss
39.00 W
Power factor λ [PIM]
0.95
Luminous flux at 35 °C
1350 lm
Number of lighting outlets
2
ECG_1.1 Ambient temperature for lifespan
40 °C
ECG_1.2 Ambient temperature for lifespan
50 °C
ECG_1.3 Ambient temperature for lifespan
60 °C
ECG_2.1 Tc point temperature for lifespa
50 °C
ECG_2.2 Tc point temperature for lifespa
60 °C
ECG_2.3 Tc point temperature for lifespa
65 °C
ECG_3.1 Temperature dependent lifespan
100000 h
ECG_3.2 Temperature dependent lifespan
100000 h
ECG_3.3 Temperature dependent lifespan
80000 h
L 23 W
Nominal current
0.26 A
Nominal wattage + Power loss
57.70 W
Luminous flux at 25 °C
1900 lm
Number of lighting outlets
1
L 30 W
Nominal current
0.28 A
Nominal wattage + Power loss
63.00 W
Power factor λ [PIM]
0.98
Luminous flux at 35 °C
2850 lm
Number of lighting outlets
2
ECG_1.1 Ambient temperature for lifespan
40 °C
ECG_1.2 Ambient temperature for lifespan
50 °C
ECG_1.3 Ambient temperature for lifespan
60 °C
ECG_2.1 Tc point temperature for lifespa
55 °C
ECG_2.2 Tc point temperature for lifespa
60 °C
ECG_2.3 Tc point temperature for lifespa
70 °C
ECG_3.1 Temperature dependent lifespan
100000 h
ECG_3.2 Temperature dependent lifespan
100000 h
ECG_3.3 Temperature dependent lifespan
70000 h
L 36 W
Nominal current
0.30 A
Nominal wattage + Power loss
71.00 W
Power factor λ [PIM]
0.98
Luminous flux at 35 °C
3200 lm
Number of lighting outlets
2
ECG_1.1 Ambient temperature for lifespan
40 °C
ECG_1.2 Ambient temperature for lifespan
50 °C
ECG_1.3 Ambient temperature for lifespan
60 °C
ECG_2.1 Tc point temperature for lifespa
55 °C
ECG_2.2 Tc point temperature for lifespa
65 °C
ECG_2.3 Tc point temperature for lifespa
70 °C
ECG_3.1 Temperature dependent lifespan
100000 h
ECG_3.2 Temperature dependent lifespan
100000 h
ECG_3.3 Temperature dependent lifespan
70000 h
NS 36W G13
Information about Family
- Supply voltage: 220 240 V
- Line voltage: 198 264 V
- Line frequency: 0 Hz | 50 Hz | 60 Hz
- Lamp start with optimum filament preheating
- Lifetime: up to 100,000 h (temperature at Tc = 65 °C, max. 10 % failure rate)
- Energy Efficiency Index EEI: A2 BAT
- Automatic shutdown of defective lamps and at end of life (EoL T.2)
- Safety: to EN 61347-2-3
- Lamp operation: to EN 60929
Separate control gear and light sources must be disposed of at certified disposal companies in accordance with Directive 2012/19/EU (WEEE) in the EU and with Waste Electrical and Electronic Equipment (WEEE) Regulations 2013 in the UK. For this purpose, collection points for recycling centres and take-back systems (CRSO) are available from retailers or private disposal companies, which accept separate control gear and light sources free of charge. In this way, raw materials are conserved and materials are recycled.
Products
Product |
|
|
|
|
|
Data sheet | ||
---|---|---|---|---|---|---|---|---|
![]() |
QTP-OPTIMAL 1X18
40
|
21.0 mm | No | 100000 h | 280.0 mm | 30.0 mm | ||
![]() |
QTP-OPTIMAL 1X54
58
|
21.0 mm | No | 100000 h | 280.0 mm | 30.0 mm | ||
![]() |
QTP-OPTIMAL 2X18
40
|
21.0 mm | No | 100000 h | 360.0 mm | 30.0 mm | ||
![]() |
QTP-OPTIMAL 2X54
58
|
21.0 mm | No | 100000 h | 360.0 mm | 30.0 mm |