QT-FIT5 1X49

Product family benefits
  • Long lamp life
  • No adverse effect from frequent on/off switching
  • Automatic restart after lamp replacement
  • Perfect lamp start for applications with motion sensors
  • VDE/VDE EMC certified system
  • Very high energy efficiency due to cut-off technology
Areas of application
  • Open-plan offices, corridors and storage rooms
  • Public buildings
  • Strip lighting
  • Suitable for luminaires of protection class I
  • Modernization of existing systems

Technical Data

Electrical data

Input voltage AC

198…264 V

Nominal voltage

220…240 V

Mains frequency

50…60 Hz

Input voltage DC

186…276 V

Minimum voltage for lamp ignition: 198 V, 185…198 V for maximum 1 h

Maximum output power

49 W

Efficiency in full-load

93 %

at 230 V, 50 Hz

Operating frequency

40…50 kHz

Max. ECG no. on circuit breaker 10 A (B)

17

Type B

Max. ECG no. on circuit breaker 16 A (B)

28

Type B

Inrush current

24 A

Light technical data

Starting time

2.0 s

Dimensions & weight

Length

280.0 mm

Width

30.0 mm

Height

21.0 mm

Mounting hole spacing, length

270.0 mm

Product weight

155.00 g

Cable cross-section, input side

0.5…1.5 mm²

Solid leads

Cable cross-section, output side

0.5…1.5 mm²

Solid leads

Temperatures & operating conditions

Ambient temperature range

-15…+50 °C

Permitted rel. humidity during operation

5…85 %

Maximum 56 days/year at 85 %

Lifespan

ECG lifetime

50000 h

Additional product data

Suitable for lamp power (1 lamp)

49 W

Capabilities

End of lamp life safety shutdown

EOL T.2

Suitable for fixtures with prot. class

I

Max. cable length to lamp/LED module

2.0 m / 1.0 m

Intended for no-load operation

No

Dimmable

No

Certificates & standards

Approval marks – approval

VDE / ENEC 10 / VDE-EMC

EEI – Energy Label

A2

Standards

Acc. to EN 61347-2-12/IEC 61347-2-12/Acc. to EN 55015:2006 + A1:2007 + A2:2009/Acc. to EN 61000-3-2/IEC 61000-3-2/Acc. to EN 61547/IEC 61547

Type of protection

IP20

Protection class

III

Logistical data

Commodity code

85041080900

Environmental information


Information according Art. 33 of EU Regulation (EC) 1907/2006 (REACh)

Date of Declaration

09-06-2023

Primary Article Identifier

4008321832139

Candidate List Substance 1

Lead

CAS No. of substance 1

7439-92-1

Safe Use Instruction

The identification of the Candidate List substance is sufficient to allow safe use of the article.

Declaration No. in SCIP database

0de9faaf-d417-4b1e-9eab-ed6f4d21aee4

Packaging information

EAN

Unit

Piece

Dimension l x w x h

Weight

Volume

4008321832139 UNV

Unpacked

1 280mm x 30mm x 21mm 155.00g 0.18dm³
4008321832146 VS

Shipping box

20 312mm x 165mm x 98mm 3241.00g 5.05dm³

Downloads

Lamp-ECG Combination
HO 49 W

Nominal current

0.24 A

Nominal wattage + Power loss

54.00 W

Power factor λ [PIM]

0.98

Luminous flux at 35 °C

4300 lm

Number of lighting outlets

1

ECG_1.1 Ambient temperature for lifespan

40 °C

ECG_1.2 Ambient temperature for lifespan

50 °C

ECG_1.3 Ambient temperature for lifespan

60 °C

ECG_2.1 Tc point temperature for lifespa

55 °C

ECG_2.2 Tc point temperature for lifespa

60 °C

ECG_2.3 Tc point temperature for lifespa

70 °C

ECG_3.1 Temperature dependent lifespan

100000 h

ECG_3.2 Temperature dependent lifespan

100000 h

ECG_3.3 Temperature dependent lifespan

70000 h

Information about Family

When it comes to ECG installation, the QUICKTRONIC FIT 5 ECG is a great option if you are using T5 lamps. Available in a choice of specifications, key features include lamp start with optimal filament preheating, an energy efficiency index of A2, and automatic shutoff of defective lamps and at end of life. Use it with luminaires of protection class I, for open-plan office lighting, corridors, storage rooms, public buildings and strip lighting. Benefits include long lamp life, the ability to withstand frequent on/off switching without harm, automatic restart after lamp replacement and very high levels of efficiency thanks to the unit’s cutoff technology. If your application uses motion sensors, this ECG will give perfect lamp start, and its VDE/VDE EMC certified system gives reliability and safety assurances.
Product family features
  • Supply voltage: 220…240 V
  • Line voltage: 198…264 V
  • Line frequency: 50 Hz | 60 Hz
  • Lamp start with optimum filament preheating
  • Energy Efficiency Index EEI: A2
  • Automatic shutdown of defective lamps and at end of life (EoL T.2)
  • Lamp operation: to EN 60929
  • Safety: to EN 61347-2-3
Ecodesign regulation information:
Separate control gear and light sources must be disposed of at certified disposal companies in accordance with Directive 2012/19/EU (WEEE) in the EU and with Waste Electrical and Electronic Equipment (WEEE) Regulations 2013 in the UK. For this purpose, collection points for recycling centres and take-back systems (CRSO) are available from retailers or private disposal companies, which accept separate control gear and light sources free of charge. In this way, raw materials are conserved and materials are recycled.

Products

Sort by:
Product
Height
Dimmable
ECG lifetime
Length
Width
Data sheet
QT-FIT5 1X14…35
21.0 mm No 50000 h 280.0 mm 30.0 mm
QT-FIT5 2X14…35
21.0 mm No 280.0 mm 30.0 mm
QT-FIT5 3X14,4X14
21.0 mm No 50000 h 280.0 mm 40.0 mm
QT-FIT5 1X49
21.0 mm No 50000 h 280.0 mm 30.0 mm
QT-FIT5 2X49
21.0 mm No 50000 h 280.0 mm 30.0 mm