QTi DALI 2X14/24 DIM

Product family benefits
  • System+ Guarantee available
  • Easy integration in luminaire thanks to same dimensions like DALI GI ECG
  • TouchDIM function for easy and inexpensive dimming of several ECGs
  • Same luminous flux with direct and alternating current
  • Dimming of amalgam lamps without flickering or reduced lifespan
  • Automatic restart after lamp replacement
DALI product features
  • Control via the DALI interface
  • Compliance with the DALI Version-1 and IEC 60929
  • Control input protected against overvoltage and polarity reversal (OSRAM ECG)
Touch DIM and Touch DIM Sensor function
  • Manual dimming without controller and with standard switches
  • Including memory function (double click) and soft start
Areas of application
  • Suitable for use in emergency lighting systems as per EN 50172/DIN VDE 0108-100
  • Installation in emergency lighting systems according to IEC 61347-2-3, appendix J
  • Industry
  • Open-plan offices, corridors and storage rooms
  • Public buildings
  • Sports halls and factories
  • Strip lighting
  • Shop lighting
  • Suitable for luminaires of protection class I

References / Links
For more information on the system guarantee and the terms and conditions of the guarantee visit https://www.inventronics-light.com/multilevel-guarantees

Technical Data

Electrical data

Input voltage AC

198…264 V

Nominal voltage

220…240 V

Mains frequency

50…60 Hz

Input voltage DC

154…276 V

Maximum output power

2 x 24 W

Efficiency in full-load

90 %

at 230 V, 50 Hz

Operating frequency

53…120 kHz

Max. ECG no. on circuit breaker 10 A (B)

12

Type B

Max. ECG no. on circuit breaker 16 A (B)

19

Type B

Inrush current

35 A

Light technical data

Starting time

0.6 s

Optimized preheat start

Dimensions & weight

Length

423.0 mm

Width

30.0 mm

Height

21.0 mm

Mounting hole spacing, length

415.0 mm

Product weight

370.00 g

Cable cross-section, output side

0.5…1.5 / 0.5…1.0 mm²

Solid leads / Flexible

Cable cross-section, input side

0.5…1.5 / 0.5…1.0 mm²

Solid leads / Flexible

Temperatures & operating conditions

Ambient temperature range

+10…+50 °C

Permitted rel. humidity during operation

5…85 %

Maximum 56 days/year at 85 %

Lifespan

ECG lifetime

100000 h

At Tcase = 65°C at Tc point / 10% failure rate

Additional product data

Suitable for lamp power (2 lamps)

14…24 W

Capabilities

Dimming interface

DALI / Touch DIM / Touch DIM Sensor

Dimming range

1…100 %

Luminous flux

Dimmable

Yes

Overheating protection

Power reduction and switch off at T > 75 °C at the tc point

Suitable for fixtures with prot. class

I

End of lamp life safety shutdown

EOL T.2

Intended for no-load operation

No

Max. cable length to lamp/LED module

1.0 m / 1.5 m

Certificates & standards

Approval marks – approval

VDE / VDE-EMC / EL / EAC / RCM / CCC

Standards

Acc. to EN 55015; EN 55022/Acc. to EN 61547/Acc. to IEC 61000-3-2/EN 61000-3-2/Acc. to EN 61347-2-3/Acc. to EN 60929/Acc. to EN 55015:2006 + A1:2007/Acc. to EN 61000-3-2/Acc. to EN 61547/Acc. to IEC 62386-101:Ed1/Acc. to IEC 62386-102:Ed1

Protection class

I

Type of protection

IP20

EEI – Energy Label

A1 BAT

Logistical data

Commodity code

85041080900

Environmental information


Information according Art. 33 of EU Regulation (EC) 1907/2006 (REACh)

Date of Declaration

19-05-2023

Primary Article Identifier

4050300870861

Candidate List Substance 1

Lead

CAS No. of substance 1

7439-92-1

Safe Use Instruction

The identification of the Candidate List substance is sufficient to allow safe use of the article.

Declaration No. in SCIP database

29a9ca70-3ca5-42b4-bc37-82894cb9c95e

Packaging information

EAN

Unit

Piece

Dimension l x w x h

Weight

Volume

4050300870861 UNV

Unpacked

1 382.00g
4050300870878 VS

Shipping box

20 455mm x 163mm x 98mm 7644.00g 7.27dm³

Downloads

Lamp-ECG Combination
DULUX F 24 W

Nominal current

0.22 A

Nominal wattage + Power loss

49.00 W

Power factor λ [PIM]

0.98

Luminous flux at 35 °C

1700 lm

Ambient temperature range [PIM] REM

Operation at up to -20 °C for all QTi (DALI) DIM-ECG possible. Lowest dimming position must be limited. Details see technical dimming brochure.

Number of lighting outlets

2

DULUX L 24 W

Nominal current

0.22 A

Nominal wattage + Power loss

49.00 W

Power factor λ [PIM]

0.98

Luminous flux at 35 °C

1800 lm

Ambient temperature range [PIM] REM

Operation at up to -20 °C for all QTi (DALI) DIM-ECG possible. Lowest dimming position must be limited. Details see technical dimming brochure.

Number of lighting outlets

2

ECG_1.1 Ambient temperature for lifespan

40 °C

ECG_1.2 Ambient temperature for lifespan

50 °C

ECG_1.3 Ambient temperature for lifespan

60 °C

ECG_2.1 Tc point temperature for lifespa

50 °C

ECG_2.2 Tc point temperature for lifespa

60 °C

ECG_2.3 Tc point temperature for lifespa

70 °C

ECG_3.1 Temperature dependent lifespan

100000 h

ECG_3.2 Temperature dependent lifespan

100000 h

ECG_3.3 Temperature dependent lifespan

100000 h

FC 22 W

Nominal current

0.22 A

Nominal wattage + Power loss

49.00 W

Power factor λ [PIM]

0.98

Luminous flux at 35 °C

1750 lm

Ambient temperature range [PIM] REM

Operation at up to -20 °C for all QTi (DALI) DIM-ECG possible. Lowest dimming position must be limited. Details see technical dimming brochure.

Number of lighting outlets

2

HE 14 W

Nominal current

0.14 A

Nominal wattage + Power loss

30.60 W

Power factor λ [PIM]

0.95

Luminous flux at 35 °C

1200 lm

Ambient temperature range [PIM] REM

Operation at up to -20 °C for all QTi (DALI) DIM-ECG possible. Lowest dimming position must be limited. Details see technical dimming brochure.

Number of lighting outlets

2

ECG_1.1 Ambient temperature for lifespan

40 °C

ECG_1.2 Ambient temperature for lifespan

50 °C

ECG_1.3 Ambient temperature for lifespan

60 °C

ECG_2.1 Tc point temperature for lifespa

50 °C

ECG_2.2 Tc point temperature for lifespa

60 °C

ECG_2.3 Tc point temperature for lifespa

70 °C

ECG_3.1 Temperature dependent lifespan

100000 h

ECG_3.2 Temperature dependent lifespan

100000 h

ECG_3.3 Temperature dependent lifespan

100000 h

HO 24 W

Nominal current

0.22 A

Nominal wattage + Power loss

49.30 W

Power factor λ [PIM]

0.98

Luminous flux at 35 °C

1750 lm

Ambient temperature range [PIM] REM

Operation at up to -20 °C for all QTi (DALI) DIM-ECG possible. Lowest dimming position must be limited. Details see technical dimming brochure.

Number of lighting outlets

2

ECG_1.1 Ambient temperature for lifespan

40 °C

ECG_1.2 Ambient temperature for lifespan

50 °C

ECG_1.3 Ambient temperature for lifespan

60 °C

ECG_2.1 Tc point temperature for lifespa

50 °C

ECG_2.2 Tc point temperature for lifespa

60 °C

ECG_2.3 Tc point temperature for lifespa

70 °C

ECG_3.1 Temperature dependent lifespan

100000 h

ECG_3.2 Temperature dependent lifespan

100000 h

ECG_3.3 Temperature dependent lifespan

100000 h

Information about Family

QUICKTRONIC INTELLIGENT DALI DIM T5 is an easy design-in; its dimensions match those of DALI GI ECG. You control it via DALI interface; control input is protected from overvoltage and polarity reversal via OSRAM ECG, and it is fit for SMART GRID feedback. The dimming range is 1...100 % (3...100 % with CFL) and a POWER2LAMP function gives you optimal matching of ECG power to the lamp. TouchDIM and TouchDIM sensor functions let you dim without a controller and with standard switches; you also benefit from a memory function and soft start option. QUICKTRONIC INTELLIGENT DALI DIM T5 is ideal for industrial lighting, corridors, sports halls, public buildings, shoplighting and strip lighting. Use it with luminaires of protection class I; benefits include the same luminous flux in amalgam lamps without flicker, the same luminous flux with AC and DC, auto restart after lamp replacement and inexpensive dimming of multiple ECGs.
Product family features
  • Corridor function for direct connection of ECG to common motion sensor
  • Corridor function with pre-programmed light program
  • Touch DIM function for free parameterization of light value and turn on time
  • Fit for SMART GRID for feedback of consumed mains power and lamp operating hours
  • Fit for emergency function for automatic detection of emergency lighting by ECG
  • Very low standby power consumption: < 0.5 W
  • Lifetime: > 100,000 h (for T = 65 °C at Tc)
  • Very high number of switching cycles: up to 300,000
  • Dimming range: 1…100 % (3…100 % with compact fluorescent lamp)
  • POWER2LAMP function for optimal matching of ECG power to lamp during lamp lifetime
  • Line frequency: 0 Hz, 50…60 Hz, rectified AC
Ecodesign regulation information:
Separate control gear and light sources must be disposed of at certified disposal companies in accordance with Directive 2012/19/EU (WEEE) in the EU and with Waste Electrical and Electronic Equipment (WEEE) Regulations 2013 in the UK. For this purpose, collection points for recycling centres and take-back systems (CRSO) are available from retailers or private disposal companies, which accept separate control gear and light sources free of charge. In this way, raw materials are conserved and materials are recycled.

Related products

Products

Sort by:
Product
Dimmable
Height
Width
Dimming interface
Dimming range
Data sheet
QTi DALI 1X14/24 DIM
Yes 21.0 mm 30.0 mm DALI / Touch DIM / Touch DIM Sensor 1…100 %
QTi DALI 2X14/24 DIM
Yes 21.0 mm 30.0 mm DALI / Touch DIM / Touch DIM Sensor 1…100 %
QTi DALI 2X35/49 DIM
Yes 21.0 mm 30.0 mm DALI / Touch DIM / Touch DIM Sensor 1…100 %
QTi DALI 3X14/24 DIM
Yes 21.0 mm 40.0 mm DALI / Touch DIM / Touch DIM Sensor 1…100 %