QTP-D/E 1X10…13

Product family benefits
  • Long lamp life
  • No adverse effect from frequent on/off switching
  • Automatic restart after lamp replacement
  • Perfect lamp start for applications with motion sensors
  • Separate installations thanks to optional cable clamp for K2 and K3 casings
  • VDE/VDE EMC certified system
Areas of application
  • Emergency lighting systems acc. to EN 50172 / DIN VDE 0108-100
  • Public buildings
  • Sports halls and factories
  • Suitable for luminaires of protection class I

Technical Data

Electrical data

Input voltage AC

198…264 V

Nominal voltage

220…240 V

Mains frequency

50…60 Hz

Input voltage DC

176…276 V

Minimum voltage for lamp ignition: 198 V

Maximum output power

13 W

Efficiency in full-load

84 %

at 230 V, 50 Hz

Operating frequency

44 kHz

Approximately

Max. ECG no. on circuit breaker 10 A (B)

25

Type B

Max. ECG no. on circuit breaker 16 A (B)

41

Type B

Inrush current

7 A

Light technical data

Starting time

1.0 s

Dimensions & weight

Length

93.0 mm

Width

58.0 mm

Height

29.0 mm

Mounting hole spacing, length

84.0 mm

Mounting hole spacing, width

48.0 mm

Product weight

100.00 g

Cable cross-section, output side

0.5…1.5 mm²

Cable cross-section, input side

0.5…1.5 mm²

Temperatures & operating conditions

Ambient temperature range

-20…+50 °C

Permitted rel. humidity during operation

5…85 %

Maximum 56 days/year at 85 %

Lifespan

ECG lifetime

50000 h

At Tcase = 75°C at Tc point / 10% failure rate

Additional product data

Product remark

Optional cable clamp, see chapter ECG mountings - cable clamp

Suitable for lamp power (1 lamp)

10…13 W

Capabilities

Suitable for fixtures with prot. class

I / II

End of lamp life safety shutdown

EOL T.2

Max. cable length to lamp/LED module

2.0 m / 1.0 m

Dimmable

No

Intended for no-load operation

No

Certificates & standards

Approval marks – approval

VDE / VDE-EMC / ENEC 10 / GOST / RCM

EEI – Energy Label

A2

Standards

Acc. to EN 61347-2-3/Acc. to EN 60929/Acc. to EN 55015:2006 + A1:2007/Acc. to EN 61000-3-2/Acc. to EN 61547

Type of protection

IP20

Protection class

III

Logistical data

Commodity code

85041080900

Environmental information


Information according Art. 33 of EU Regulation (EC) 1907/2006 (REACh)

Date of Declaration

26-05-2023

Primary Article Identifier

4008321181572

Candidate List Substance 1

Lead

CAS No. of substance 1

7439-92-1

Safe Use Instruction

The identification of the Candidate List substance is sufficient to allow safe use of the article.

Declaration No. in SCIP database

fef93e49-eb7b-490b-9306-a53496787bc1

Packaging information

EAN

Unit

Piece

Dimension l x w x h

Weight

Volume

4008321181572 UNV

Unpacked

1 93mm x 58mm x 29mm 100.00g 0.16dm³
4008321181589 VS

Shipping box

20 315mm x 196mm x 66mm 2127.00g 4.07dm³

Downloads

Lamp-ECG Combination
DULUX D/E 10 W

Nominal current

0.05 A

Nominal wattage + Power loss

12.00 W

Power factor λ [PIM]

0.95

Luminous flux at 25 °C

600 lm

Number of lighting outlets

1

DULUX S/E 11 W

Nominal current

0.06 A

Nominal wattage + Power loss

14.00 W

Power factor λ [PIM]

0.95

Luminous flux at 25 °C

900 lm

Number of lighting outlets

1

DULUX S/E 9 W

Nominal current

0.05 A

Nominal wattage + Power loss

9.50 W

Power factor λ [PIM]

0.92 c

Luminous flux at 25 °C

600 lm

Number of lighting outlets

1

Information about Family

If you need a high performance, energy efficient ECG to use with compact fluorescent lamps, the QUICKTRONIC PROFESSIONAL M, which is available in several variants, may be ideal. It gives you lamp start with optimum filament preheating, auto shutdown of defective lamps and at end of life, and an energy efficiency index of A2, and you can use it in emergency lighting systems to EN 50172 / DIN VDE 0108-100. Used with luminaires of protection class I, you may find it particularly useful for professional lighting systems in public buildings, sports halls and industrial lighting, including factories. QUICKTRONIC PROFESSIONAL M is a great addition to a light management system (LMS) and provides perfect lamp start for applications with motion sensors. Other benefits include its ability to resist frequent on/off switching, and long lamp life. You can install this ECG separately with the optional cable clamp for K2 and K3 casings.
Product family features
  • Supply voltage: 220…240 V
  • Line voltage: 198…264 V
  • Line frequency: 0 Hz | 50 Hz | 60 Hz
  • Lamp start with optimum filament preheating
  • Energy Efficiency Index EEI: A2
  • Automatic shutdown of defective lamps and at end of life (EoL T.2)
  • Lamp operation: to EN 60929
  • Safety: to EN 61347-2-3
Ecodesign regulation information:
Separate control gear and light sources must be disposed of at certified disposal companies in accordance with Directive 2012/19/EU (WEEE) in the EU and with Waste Electrical and Electronic Equipment (WEEE) Regulations 2013 in the UK. For this purpose, collection points for recycling centres and take-back systems (CRSO) are available from retailers or private disposal companies, which accept separate control gear and light sources free of charge. In this way, raw materials are conserved and materials are recycled.

Products

Sort by:
Product
Height
Dimmable
ECG lifetime
Length
Width
Data sheet
QTP-D/E 2X10…13
33.0 mm No 50000 h 123.0 mm 79.0 mm
QTP-T/E 1X18,2X18
31.0 mm No 50000 h 103.0 mm 67.0 mm
QTP-T/E 1X26…42,2X26
31.0 mm No 50000 h 103.0 mm 67.0 mm
QTP-D/E 1X10…13
29.0 mm No 50000 h 93.0 mm 58.0 mm