OT FIT 55/220...240/1A0 NFC L

Product family benefits
  • Flexible and future-proof current setting via NFC (Near Field Communication)
  • Lifetime: up to 100,000 h (temperature at Tc = 65 °C, max. 10 % failure rate)
  • Fulfilling SVM (≤ 0.4) and PsT (≤ 1.0) standards
  • Higher quality of light thanks to < 1% output ripple current
  • Very high efficiency
  • Fulfill safety requirement due to overload, overtemperature protection
Areas of application
  • Linear lighting for office, education, industry, storage areas and retail
  • Installation in emergency lighting systems according to IEC 61347-2-13, appendix J
  • Suitable for luminaires of protection class I
German innovation awards 2019 winner

Technical Data

Electrical data

Nominal input voltage

220…240 V

Mains frequency

50/60 Hz

Input voltage AC

198…264 V

Input voltage DC

176…276 V

Current set

NFC

Power factor λ

0.71C...0.96

Efficiency in full-load

90 %

at 230 V, 50 Hz

Device power loss

5.0 W

Inrush current

≤ 20 A

Max. ECG no. on circuit breaker 10 A (B)

8

Max. ECG no. on circuit breaker 10 A (C)

-

Max. ECG no. on circuit breaker 16 A (B)

13

Max. ECG no. on circuit breaker 16 A (C)

-

Max. ECG no. on circuit breaker 25 A (B)

-

Surge capability (L/N-Ground)

2 kV

Surge capability (L-N)

1 kV

Nominal output voltage

20…51 V

Nominal output current

400…1050 mA

Output PSTLM

≤1

Output SVM

≤0.4

Nominal output power

21…55 W

Maximum output power

55 W

Dimensions & weight

Mounting hole spacing, length

270.0 mm

Product weight

200.00 g

Cable cross-section, input side

0.5…1.5 mm²

Wire preparation length, input side

8.0…9.0 mm

Wire preparation length, output side

8.0…9.0 mm

Height

21.0 mm

Width

30.0 mm

Length

280.0 mm

Colors & materials

Casing material

Metal

Temperatures & operating conditions

Ambient temperature range

-25…+50 °C

Maximum temperature at tc test point

75 °C

Max.housing temperature in case of fault

110 °C

Temperature range at storage

-40…+85 °C

Permitted rel. humidity during operation

5…85 %

Maximum 56 days/year at 85 %

Lifespan

ECG lifetime

100000 h

Capabilities

Dimmable

No

Overheating protection

Automatic reversible

Overload protection

Automatic reversible

Short-circuit protection

Automatic reversible

No-load proof

Yes

Intended for no-load operation

No

Max. cable length to lamp/LED module

2.0 m

Output wires must be routed as close as possible to each other

Suitable for fixtures with prot. class

I

Number of channels

1

Suitable for emergency lighting

Yes

Programming

Programming device

FEIG

Box programming

Yes

Certificates & standards

Approval marks – approval

CE / VDE-ENEC / EAC / CCC / BIS / RCM

Standards

Acc. to IEC 61347-1/Acc. to IEC 61347-2-13/Acc. to IEC 62384/Acc. to IEC 62386/Acc. to IEC 61000-3-2/Acc. to IEC 61000-3-3/Acc. to IEC 61547

Type of protection

IP20

Logistical data

Commodity code

85044083900

Environmental information


Information according Art. 33 of EU Regulation (EC) 1907/2006 (REACh)

Date of Declaration

24-05-2023

Primary Article Identifier

4062172064026

Candidate List Substance 1

Lead

CAS No. of substance 1

7439-92-1

Safe Use Instruction

The identification of the Candidate List substance is sufficient to allow safe use of the article.

Declaration No. in SCIP database

022163c1-2dbe-4e74-98e0-c0246326132f

Packaging information

EAN

Unit

Piece

Dimension l x w x h

Weight

Volume

4062172064026 UNV

Unpacked

1 280mm x 30mm x 21mm 200.00g 0.18dm³
4062172211819 VS

Shipping box

10 309mm x 120mm x 78mm 2101.00g 2.89dm³

Downloads

Information about Family

Product family features
  • Line frequency: 0 Hz | 50 Hz | 60 Hz
  • Versatile scope of application due to output power range of up to 75 W
  • Constant Lumen Output (CLO)
  • Supply voltage: 220…240 V
  • Available with output current range: up to 1,400 mA
  • SELV driver
Ecodesign regulation information:
Intended for use with LED modules.
The forward voltage of the LED light source shall be within the defined operating window of the control gear in all operating conditions including dimming if applicable.

Separate control gear and light sources must be disposed of at certified disposal companies in accordance with Directive 2012/19/EU (WEEE) in the EU and with Waste Electrical and Electronic Equipment (WEEE) Regulations 2013 in the UK. For this purpose, collection points for recycling centres and take-back systems (CRSO) are available from retailers or private disposal companies, which accept separate control gear and light sources free of charge. In this way, raw materials are conserved and materials are recycled.

Products

Sort by:
Product
Nominal output voltage
Nominal output current
Length
Width
Height
Data sheet
OT FIT 25/220...240/500 NFC L
20…51 V 170…500 mA 280.0 mm 30.0 mm 21.0 mm
OT FIT 35/220...240/700 NFC L
20…51 V 250…700 mA 280.0 mm 30.0 mm 21.0 mm
OT FIT 55/220...240/1A0 NFC L
20…51 V 400…1050 mA 280.0 mm 30.0 mm 21.0 mm
OT FIT 75/220...240/1A4 NFC L
20…51 V 600…1400 mA 280.0 mm 30.0 mm 21.0 mm