OT FIT 500/220...400/1A6 D NFC HC B L

Product family benefits
  • Flexible and future-proof current setting via NFC (Near Field Communication)
  • Lifetime: up to 100,000 h (temperature at Tc = 65 °C, max. 10 % failure rate)
  • Higher quality of light thanks to < 1% output ripple current
  • Very high efficiency (up to 97%)
  • Protection against 4 kV burst and 2 kV surge voltage (L-N and L-N/PE)
Areas of application
  • Linear and area lighting
  • Horticulture lighting
  • Industry lighting
  • Suitable for luminaires of protection class I
German innovation awards 2019 winner

Technical Data

Electrical data

Nominal input voltage

220…400 V

Mains frequency

50…60 Hz

Input voltage AC

198…440 V

Current set

NFC

Power factor λ

> 0.98

Efficiency in full-load

96 %

at 230 V, 50 Hz

Device power loss

24 / 19 W

At 230 V = 24 W / At 400 V = 19 W

Inrush current

9.4 / 15.9 A

At 230 V = 9.4 A / At 400 V = 15.9 A

Max. ECG no. on circuit breaker 10 A (B)

-

Max. ECG no. on circuit breaker 10 A (C)

-

Max. ECG no. on circuit breaker 16 A (B)

5 / 12

At 230 V = 5 / At 400 V = 12

Max. ECG no. on circuit breaker 16 A (C)

5 / 15

At 230 V = 5 / At 400 V = 15

Max. ECG no. on circuit breaker 25 A (B)

8 / 18

At 230 V = 8 / At 400 V = 18

Surge capability (L/N-Ground)

2 kV

Surge capability (L-N)

2 kV

Nominal output voltage

150…550 V

Nominal output current

400…1600 mA

Output PSTLM

≤1

Output SVM

≤0.4

Nominal output power

200…525 W

Maximum output power

525 W

Galvanic isolation

Non isolated

Default output current

400 mA

Output ripple current (100 Hz)

< 1 %

Dimensions & weight

Mounting hole spacing, length

258.0 mm

Product weight

1400.00 g

Height

43.0 mm

Length

312.0 mm

Width

136.0 mm

Temperatures & operating conditions

Ambient temperature range

-25…+50 °C

Maximum temperature at tc test point

50 °C

Max.housing temperature in case of fault

110 °C

Temperature range at storage

-40…+85 °C

Permitted rel. humidity during operation

5…85 %

Maximum 56 days/year at 85 %

Lifespan

ECG lifetime

100000 / 50000 h

Additional product data

Encapsulated

No

Capabilities

Dimmable

No

Overheating protection

Yes

Overload protection

Yes

Short-circuit protection

Yes

No-load proof

Yes

Intended for no-load operation

No

Max. cable length to lamp/LED module

2.5 m

Output wires must be routed as close as possible to each other

Suitable for fixtures with prot. class

I

Number of channels

1

Control interface

NFC

Programming

Programming device

DALI magic / FEIG

Tuner4TRONIC Field App

Yes

Tuner4TRONIC

Yes

Certificates & standards

Approval marks – approval

CE

Standards

Acc. to EN 61347-1/Acc. to EN 61347-2-13/Acc. to EN 62384/Acc. to EN 61000-3-2/Acc. to EN 61000-3-3/Acc. to EN 61547

Type of protection

IP20

Logistical data

Commodity code

85044083900

Environmental information


Information according Art. 33 of EU Regulation (EC) 1907/2006 (REACh)

Date of Declaration

30-06-2023

Primary Article Identifier

4052899624436

Candidate List Substance 1

Lead

CAS No. of substance 1

7439-92-1

Safe Use Instruction

The identification of the Candidate List substance is sufficient to allow safe use of the article.

Declaration No. in SCIP database

ded81c24-8505-42b9-8430-f8e83477fc0d

Packaging information

EAN

Unit

Piece

Dimension l x w x h

Weight

Volume

4052899624436 UNV

Unpacked

1 312mm x 136mm x 43mm 1400.00g 1.82dm³
4052899624450 VS

Shipping box

5 345mm x 265mm x 165mm 7468.00g 15.09dm³

Downloads

Information about Family

Product family features
  • 1- and 2-channels drivers
  • Line frequency: 47.5…60 Hz
  • Versatile scope of application due to output power range of up to 1050 W
  • Supply voltage: 220…240 V / 400 V
  • Available with output current range: up to 1,600 mA
  • Non-isolated drivers
Ecodesign regulation information:
Intended for use with LED modules.
The forward voltage of the LED light source shall be within the defined operating window of the control gear in all operating conditions including dimming if applicable.

Separate control gear and light sources must be disposed of at certified disposal companies in accordance with Directive 2012/19/EU (WEEE) in the EU and with Waste Electrical and Electronic Equipment (WEEE) Regulations 2013 in the UK. For this purpose, collection points for recycling centres and take-back systems (CRSO) are available from retailers or private disposal companies, which accept separate control gear and light sources free of charge. In this way, raw materials are conserved and materials are recycled.

Products

Sort by:
Product
Nominal output voltage
Nominal output current
Length
Width
Height
Data sheet
OT FIT 500/220...400/1A6 D NFC HC B L
150…550 V 400…1600 mA 312.0 mm 136.0 mm 43.0 mm
OT FIT 1000/220...400/1A6 D NFC HC 2CH B L
150…550 V 400…1600 mA 312.0 mm 136.0 mm 43.0 mm