Key features
- 8 outputs for DMX512/RDM or e:pix (dependent on model)
- Isolated outputs up to 3,75kV
- Integrated protection against surge (Level 3)
- Protection against miswiring
- Extended operating temperature -40….70°C*
- Embedded temperature & humidity sensors
- Reverse polarity protection
- Backup-mode on data loss
- Power-over-Ethernet
- Test mode access via button
- Web interface for status and configuration
- Simple and easy integration in e:cue SYMPHOLIGHT & LAS
- Flexible mounting on 35 mm DIN rails or vertical surfaces
Technical Specifications
Dimensions (W x H x D) | 143 x 92 x 62 mm / 5.63 x 3.6 x 2.4 in (excl. fastening clip) |
Weight | 250 g / 0.55 lb |
Power supply | 24 ... 48 V DC (terminal plug) or PoE IEEE 802.3af on RJ45 |
Power consumption | max. 8 W (incl. DMX termination) |
Operating temperature | -40 ... 70 °C* / -40 ... 158 °F* |
Storage temperature | -40 ... 70 °C / -40 ... 158 °F |
Electrical safety | SELV |
Operating/storage hum. | 0 ... 80% non-condensing |
Protection Class | IP20 |
Housing material | Self extinguishing blend PC/ABS |
Mounting | on 35 mm DIN rail (DIN 43880) (19-inch rack) or with key hole on any stable vertical surface |
Certification | CE, ETL, UKCA |
Interface | 8 x DMX512 isolated in pairs (3.75 kV) surge protection, reverse polarity protection 3-pin terminal plug |
Interface specifications | VDMXmax / VDMXmin = 4.6 V / 0.8 V Short circuit protected: ISCmax = 100 mA |
Ethernet-Port | 1 x e:net 10/100 Mbit/s, RJ-45 surge protection |
Sensors | Temperature -40 ... 120 ±°C (0.2 °C) Humidity 0 ... 100% (±2%) |
User interface | LEDs for error, Ethernet activity, device status, DMX/RDM status Identify button, Test button |
* 70 °C / 158 °F for max. 1 hour/day; continuous operation at max. 60 °C / 140 °F. |