OT FIT 18/220…240/350 D CS L

Product family benefits
  • Flexible current setting (DIPswitch – 6 currents)
  • Higher quality of light thanks to low output ripple current
  • High efficiency
  • User flexibility with six different output currents from one driver
  • Safety requirement due to overload, overtemperature, short-circuit protection
  • Long reliable life at maximum permitted temperatures
  • Enable slim fixture design with flat 21 mm height metal housing
Areas of application
  • Linear and area lighting
  • Office, industrial and shop lighting
  • Suitable for luminaires of protection class I
  • Installation in emergency lighting systems according to IEC 61347-2-13, appendix J
  • Suitable for installation in emergency lighting systems according to EN 60598-2-22

Technical Data

Electrical data

Nominal input voltage

220…240 V

Mains frequency

0/50/60 Hz

Input voltage AC

198…264 V

Current set

DipSwitch

Power factor λ

078C097

Efficiency in full-load

86 %

at 230 V, 50 Hz

Device power loss

3.08 W

Full load, 230 Vac, 50Hz / 60Hz

Inrush current

7.4 A

At 258 µs

Max. ECG no. on circuit breaker 10 A (B)

40

Max. ECG no. on circuit breaker 16 A (B)

64

Surge capability (L/N-Ground)

2 kV

L/N – PE acc to EN 61547 Cluase 5.7

Surge capability (L-N)

1 kV

Nominal output voltage

32...54 V

Nominal output current

100 / 150 / 200 / 250 / 300 / 350 mA

Default current 350 mA

Output PSTLM

≤1

Output SVM

≤0.4

Nominal output power

5...18.9 W

Partial load

Maximum output power

18.9 W

Output ripple current (100 Hz)

< 3 %

Dimensions & weight

Mounting hole spacing, length

200.0 mm

Product weight

11600 g

Cable cross-section, input side

0.5…1.5 mm²

Wire preparation length, input side

8.0…9.0 mm

Height

210 mm

Length

2100 mm

Width

300 mm

Temperatures & operating conditions

Ambient temperature range

-25…+50 °C

Maximum temperature at tc test point

75 °C

Max.housing temperature in case of fault

110 °C

Temperature range at storage

-25…85 °C

Permitted rel. humidity during operation

5…85 %

Non-condensing

Lifespan

ECG lifetime

50000 / 100000 h

At maximum Tc = 75°C / 10% failure rate / At maximum Tc = 65°C / 10% failure rate

Capabilities

Dimmable

No

Overheating protection

Automatic reversible

Overload protection

Automatic reversible

Short-circuit protection

Automatic reversible

No-load proof

Yes

Intended for no-load operation

No

Max. cable length to lamp/LED module

2.0 m

Output wires must be routed as close as possible to each other

Suitable for fixtures with prot. class

I

Number of channels

1

Programming

Programming device

DIPswitch

Certificates & standards

Approval marks – approval

CE / ENEC / CCC / RCM / UKCA / BIS / EAC

Standards

Acc. to IEC 61347-1/Acc. to IEC 61347-2-13/Acc. to IEC 62384/Acc. to IEC 61000-3-2/Acc. to IEC 61000-3-3/Acc. to IEC 61547/Acc. to EN 55015

Type of protection

IP20

Logistical data

Commodity code

85044083900

Environmental information


Information according Art. 33 of EU Regulation (EC) 1907/2006 (REACh)

Date of Declaration

25-08-2023

Primary Article Identifier

4062172285254

Candidate List Substance 1

Lead

CAS No. of substance 1

7439-92-1

Safe Use Instruction

The identification of the Candidate List substance is sufficient to allow safe use of the article.

Declaration No. in SCIP database

f881b08b-40f0-4875-929d-51c0aa29dff9

Packaging information

EAN

Unit

Piece

Dimension l x w x h

Weight

Volume

4062172285254 UNV

Unpacked

1 210mm x 30mm x 21mm 116.00g 0.13dm³
4062172285261 VS

Shipping box

20 237mm x 162mm x 130mm 2629.00g 4.99dm³

Downloads

Information about Family

Product family features
  • Line frequency: 0 Hz | 50 Hz | 60 Hz
  • Supply voltage: 220…240 V
  • Line voltage: 198…264 V
  • DC detection (0 Hz, pulsating DC), on/off switchable
  • Wide output current range
  • Lifetime: up to 100,000 h (temperature at Tc = 65 °C, max. 10 % failure rate)
  • Non-isolated drivers
Ecodesign regulation information:
Intended for use with LED modules.
The forward voltage of the LED light source shall be within the defined operating window of the control gear in all operating conditions including dimming if applicable.

Separate control gear and light sources must be disposed of at certified disposal companies in accordance with Directive 2012/19/EU (WEEE) in the EU and with Waste Electrical and Electronic Equipment (WEEE) Regulations 2013 in the UK. For this purpose, collection points for recycling centres and take-back systems (CRSO) are available from retailers or private disposal companies, which accept separate control gear and light sources free of charge. In this way, raw materials are conserved and materials are recycled.

Products

Sort by:
Product
Nominal output voltage
Nominal output current
Length
Width
Height
Data sheet
OT FIT 18/220…240/350 D CS L
32...54 V 100 / 150 / 200 / 250 / 300 / 350 mA 2100 mm 300 mm 210 mm
OT FIT 40/220…240/350 D CS L
40…120 V 100 / 150 / 200 / 250 / 300 / 350 mA 2100 mm 300 mm 210 mm
OT FIT 60/220…240/350 D CS L
90…175 V 100 / 150 / 200 / 250 / 300 / 350 mA 210.0 mm 30.0 mm 21.0 mm
OT FIT 75/220...240/550 D CS L
90…216 / 90…188 / 90…167 / 90…150 / 90…136 V 300 / 350 / 400 / 450 / 500 / 550 mA 2100 mm 300 mm 210 mm