QTi 2X14/24 DIM
- Same luminous flux with direct and alternating current
- Perfect lamp start for applications with motion sensors
- Dimming of amalgam lamps without flickering or reduced lifespan
- Very high efficiency thanks to cut-off technology
- Automatic restart after lamp replacement
- ECGs comply with MINERGIE standard due to very low standby consumption
- Configurable emergency power characteristics
- Suitable for emergency installations
- Industry
- Open-plan offices, corridors and storage rooms
- Public buildings
- Suitable for luminaires of protection class I
Technical Data
Electrical data
Input voltage AC
198 264 V
Nominal voltage
220 240 V
Mains frequency
50 60 Hz
Input voltage DC
154 276 V
Maximum output power
2 x 24 W
Efficiency in full-load
90 %
Operating frequency
53 120 kHz
Max. ECG no. on circuit breaker 10 A (B)
12
Max. ECG no. on circuit breaker 16 A (B)
19
Inrush current
35 A
Light technical data
Starting time
0.6 s
Dimensions & weight
Length
423.0 mm
Width
30.0 mm
Height
21.0 mm
Mounting hole spacing, length
415.0 mm
Product weight
370.00 g
Cable cross-section, output side
0.5 1.5 / 0.5 1.0 mm²
Cable cross-section, input side
0.5 1.5 / 0.5 1.0 mm²
Temperatures & operating conditions
Ambient temperature range
+10 +50 °C
Permitted rel. humidity during operation
5 85 %
Lifespan
ECG lifetime
100000 h
Additional product data
Suitable for lamp power (2 lamps)
14 24 W
Capabilities
Dimming interface
1 10 V
Dimming range
1 100 %
Dimmable
Yes
Overheating protection
Power reduction and switch off at T > 75 °C at the tc point
Suitable for fixtures with prot. class
I
End of lamp life safety shutdown
EOL T.2
Intended for no-load operation
No
Max. cable length to lamp/LED module
1.0 m / 1.5 m
Certificates & standards
Approval marks approval
VDE / VDE-EMC / EL / EAC / RCM / CCC
Standards
Acc. to EN 55015; EN 55022/Acc. to EN 61547/Acc. to IEC 61000-3-2/EN 61000-3-2
EEI Energy Label
A1 BAT
Type of protection
IP20
Protection class
I
Logistical data
Commodity code
85041080900
Environmental information
Information according Art. 33 of EU Regulation (EC) 1907/2006 (REACh)
Date of Declaration
19-05-2023
Primary Article Identifier
4050300870946
Candidate List Substance 1
Lead
CAS No. of substance 1
7439-92-1
Safe Use Instruction
The identification of the Candidate List substance is sufficient to allow safe use of the article.
Declaration No. in SCIP database
e005c7bc-c360-430a-aa86-54ecd4e439b2
Packaging information
EAN |
Unit |
Piece |
Dimension l x w x h |
Weight |
Volume |
---|---|---|---|---|---|
4050300870946 |
UNV
| 1 | 423mm x 30mm x 21mm | 370.00g | 0.27dm³ |
4050300870953 |
VS
| 20 | 455mm x 163mm x 98mm | 7645.00g | 7.27dm³ |
Downloads
Lamp-ECG Combination
DULUX F 24 W
Nominal current
0.22 A
Nominal wattage + Power loss
49.00 W
Power factor λ [PIM]
0.98
Luminous flux at 35 °C
1700 lm
Ambient temperature range [PIM] REM
Operation at up to -20 °C for all QTi (DALI) DIM-ECG possible. Lowest dimming position must be limited. Details see technical dimming brochure.
Number of lighting outlets
2
DULUX L 24 W
Nominal current
0.22 A
Nominal wattage + Power loss
49.00 W
Power factor λ [PIM]
0.98
Luminous flux at 35 °C
1800 lm
Ambient temperature range [PIM] REM
Operation at up to -20 °C for all QTi (DALI) DIM-ECG possible. Lowest dimming position must be limited. Details see technical dimming brochure.
Number of lighting outlets
2
FC 22 W
Nominal current
0.22 A
Nominal wattage + Power loss
49.00 W
Power factor λ [PIM]
0.98
Luminous flux at 35 °C
1750 lm
Ambient temperature range [PIM] REM
Operation at up to -20 °C for all QTi (DALI) DIM-ECG possible. Lowest dimming position must be limited. Details see technical dimming brochure.
Number of lighting outlets
2
HE 14 W
Nominal current
0.14 A
Nominal wattage + Power loss
30.60 W
Power factor λ [PIM]
0.96
Luminous flux at 35 °C
1200 lm
Ambient temperature range [PIM] REM
Operation at up to -20 °C for all QTi (DALI) DIM-ECG possible. Lowest dimming position must be limited. Details see technical dimming brochure.
Number of lighting outlets
2
HO 24 W
Nominal current
0.22 A
Nominal wattage + Power loss
50.00 W
Power factor λ [PIM]
0.96
Luminous flux at 35 °C
1750 lm
Ambient temperature range [PIM] REM
Operation at up to -20 °C for all QTi (DALI) DIM-ECG possible. Lowest dimming position must be limited. Details see technical dimming brochure.
Number of lighting outlets
2
Information about Family
- Control via 1 10 V interface
- Supply voltage: 220 240 V
- Line frequency: 0 Hz | 50 Hz | 60 Hz
- Line voltage: 198 264 V
- Dimming range: 1 100 % luminous flux
- Lamp start: within 0.6 s
- Lifetime: > 100,000 h (for T = 65 °C at Tc)
- Automatic shutdown of defective lamps and at end of life (EoL T.2)
- Energy Efficiency Index EEI: A1 BAT
- Overtemperature protection: Thermal management at high tc temperatures
- Safety: to EN 61347-2-3
- Lamp operation: to EN 60929
- RI suppression: to EN 55015:2006+A1:2007+A2:2009/CISPR 15
- Line harmonics according to EN 61000-3-2
- Immunity according to EN 61547
Separate control gear and light sources must be disposed of at certified disposal companies in accordance with Directive 2012/19/EU (WEEE) in the EU and with Waste Electrical and Electronic Equipment (WEEE) Regulations 2013 in the UK. For this purpose, collection points for recycling centres and take-back systems (CRSO) are available from retailers or private disposal companies, which accept separate control gear and light sources free of charge. In this way, raw materials are conserved and materials are recycled.
Products
Product |
|
|
|
|
|
Data sheet | ||
---|---|---|---|---|---|---|---|---|
![]() |
QTi 1X14/24 DIM
|
Yes | 30.0 mm | 21.0 mm | 1 10 V | 1 100 % | ||
![]() |
QTi 2X14/24 DIM
|
Yes | 30.0 mm | 21.0 mm | 1 10 V | 1 100 % | ||
![]() |
QTi 2X21/39 DIM
|
Yes | 30.0 mm | 21.0 mm | 1 10 V | 1 100 % | ||
![]() |
QTi 3X14/24 DIM
|
Yes | 40.0 mm | 21.0 mm | 1 10 V | 1 100 % | ||
![]() |
QTi 4X14/24 DIM
|